      인공 슬관절 전치환술에서 두가지 슬개삽입물의 비교 = Comparison of the Two Types of Patellar Component in Total Knee Arthroplasty

      한글로보기

      https://www.riss.kr/link?id=A3286999

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The displacement of patellar components, such as dislocation or subluxation, causes polyethylene wear and further induces metallosis of the metal-backed patella. We compared two different patellar components, onset(Miller-...

      The displacement of patellar components, such as dislocation or subluxation, causes
      polyethylene wear and further induces metallosis of the metal-backed patella. We
      compared two different patellar components, onset(Miller-Galante I) and
      inset(Whiteside-Ortholoc I)type, to understand the differences in patellar tracking
      according to their designs. Patellar prosthesis position in 43 primary total knee
      arthroplasties was evaluated with patellar tilt, patellar displacement from the center of
      the trochlear groove, medial placement, patellar thickness, and joint line height. For the
      MG(Miller-Galante I)group, the patellar displacement was laterally 50.0% and for the
      Ortholoc group, it was 33.3%. In the MG group, 4 cases of revision of the patellar
      component due to excessive polyethylene wear were performed, but there was no
      excessive wear of polyethylene in Ortholoc group. One of the primary factors which
      influence tracking of the patellofemoral joint is the difference in design between the
      patellar component and the femoral component. But in the opinion of the authors, the
      slope or lateral displacement of the patellar component have no correlation with each
      other under radiological measurements. However, the inset-type patellar component is a
      design that maintains the bony flange within the lateral flange, therefore relieving the
      shear stress and rotational forces loaded on the patellofemoral joint and protecting the
      metal-backing from exposure. Thereby, even if dislocation or subluxation of the patellar
      component should occur, polyethylene wear or metallosis caused by excessive wearing
      can be minimal.