This paper presents a case study to investigate the difference between the dynamic energy simulation and the monthly calculation method of ISO 13790 applied for a building. This study compare simulation results from the aforementioned two methods. As ...
This paper presents a case study to investigate the difference between the dynamic energy simulation and the monthly calculation method of ISO 13790 applied for a building. This study compare simulation results from the aforementioned two methods. As a dynamic energy simulation tool, EnergyPlus developed by DOE (US federal Department Of Energy) is utilized and CE3 (Construction Energy Efficiency Evaluation) program is used for monthly calculation of ISO 13790. The results indicate that both of two methods deliver meaningful information to DM (Desicion Maker). In the paper, pros and cons of two methods are discussed.