<P>Grazing incidence optics used in soft X-ray microscopes require supersmooth surface and highly accurate figure. We considered the fabrication of a Wolter type I mirror, one of grazing incidence optics, with axial-symmetric inner reflecting su...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A107689925
2007
-
500
SCOPUS
학술저널
39-42(4쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
<P>Grazing incidence optics used in soft X-ray microscopes require supersmooth surface and highly accurate figure. We considered the fabrication of a Wolter type I mirror, one of grazing incidence optics, with axial-symmetric inner reflecting su...
<P>Grazing incidence optics used in soft X-ray microscopes require supersmooth surface and highly accurate figure. We considered the fabrication of a Wolter type I mirror, one of grazing incidence optics, with axial-symmetric inner reflecting surfaces using single-point diamond turning. Electroless nickel was chosen as reflecting material Cutting conditions for machining the inner reflecting surface were restricted because of long arm of a single-crystal diamond tool. The machined Wolter type I mirror had approximately 270 nm P-V in figure error and 3 nm Ra in surface roughness. The direct-machined Wolter type I mirror could be successfully used in a soft Xray microscope based on laser-produced X-ray source.</P>