      DCV시스템에 있어서 댐퍼개폐율에 따른 풍량제어특성 평가연구 = The Evaluation on the Control Characteristics of Air Volume according to the Stroke Ratio of Damper Blade in Demand Controlled Ventilation(DCV) System

      한글로보기

      https://www.riss.kr/link?id=A45051220

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Ventilation is important for the health and comfort of building occupants it is necessary to dilute and remove pollutants emitted from indoor source such as those derived from metabolism and from the activities of occupants Demand Controlled Ventilati...

      Ventilation is important for the health and comfort of building occupants it is necessary to dilute and remove pollutants emitted from indoor source such as those derived from metabolism and from the activities of occupants Demand Controlled Ventilation system (DCV system) is possible to calculate the ventilation requirements to prevent pollutants from exceeding the threshold concentration level Also, the system can provides the ventilation rates automatically by means of motor damper and maintain indoor mr quality under the setting concentration level with response to variations of the pollutant levels Existing DCV system is being controlled by the stroke of damper blade But, ventilation rate is not proportional to the stroke ratio of damper blade Therefore, the control characteristics of damper is required for the proper control of ventilation rate
      in this study, the experimental ventilation system for the DCV control is established to figure out the control characteristics of damper blade After measurement of various experimental cases according to the stroke ratio of damper blade, logical concepts of the stroke ratio for the DCV system is suggested to provide the appropriate ventilation and to ensure the good indoor air quality

      더보기

      참고문헌 (Reference)

      1 "실내환경 IAQ 통합조절시스템 개발" 산업자원부 2001.10

      2 "Ventilation for Acceptable Indoor Air Quality, American Society of Heating" 1989.

      3 "Ventilation and Building Airtightness" 1994

      4 "Ventilation Effectiveness and Purging Flow Rate" July22-24,1992

      5 "The Use of Moments for Assessing Air Quality in Ventilation Rooms" 18 (18): 181-197, 1983

      6 "Model Experiment and Numerical Simulation of Air Change Efficiency in a Room Using Different Air Conditioning Configurations" July17-19,1996

      7 "Indoor Air Quality Problems and Control Strategies" 2000.10

      8 "Experimental Study on Indoor Thermal Environment and Ventilation Performance of Floor-Supply Displacement Ventilation System" Architectural Institute of Japan (499) : 17 -25, Sep.,1997

      9 "E741 Standard Test Method for Determining Air Change in a Single Zone by Means of Tracer Gas Dilution" American Society for Testion and Materials, Philadelphia 1993.

      10 "Demand Controlled Ventilating System-State of the Art Review" 1990

      1 "실내환경 IAQ 통합조절시스템 개발" 산업자원부 2001.10

      2 "Ventilation for Acceptable Indoor Air Quality, American Society of Heating" 1989.

      3 "Ventilation and Building Airtightness" 1994

      4 "Ventilation Effectiveness and Purging Flow Rate" July22-24,1992

      5 "The Use of Moments for Assessing Air Quality in Ventilation Rooms" 18 (18): 181-197, 1983

      6 "Model Experiment and Numerical Simulation of Air Change Efficiency in a Room Using Different Air Conditioning Configurations" July17-19,1996

      7 "Indoor Air Quality Problems and Control Strategies" 2000.10

      8 "Experimental Study on Indoor Thermal Environment and Ventilation Performance of Floor-Supply Displacement Ventilation System" Architectural Institute of Japan (499) : 17 -25, Sep.,1997

      9 "E741 Standard Test Method for Determining Air Change in a Single Zone by Means of Tracer Gas Dilution" American Society for Testion and Materials, Philadelphia 1993.

      10 "Demand Controlled Ventilating System-State of the Art Review" 1990

      11 "A study of ventilation measurement in an office building, NISTIR 4905" 1992.(接受:2004.2.4)

      12 "A Guide to Energy Efficient Ventilation" Great Britain 1995

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2022 평가예정 계속평가 신청대상 (등재유지)
      2017-01-01 평가 우수등재학술지 선정 (계속평가)
      2013-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2011-03-25 학술지명변경 한글명 : 대한건축학회논문집 -> 대한건축학회논문집 계획계
      외국어명 : Journal of the Architectural Institute of Korea -> Journal of the Architectural Institute of Korea Planning & Design
      KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-08-02 학술지명변경 외국어명 : Journal of the Architectural Institute of Korea, Structure&Construction -> Journal of the Architectural Institute of Korea KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-10-14 학술지명변경 한글명 : 대한건축학회논문집 구조계 -> 대한건축학회논문집 KCI등재
      2004-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2001-07-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1999-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.38 0.38 0.38
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.41 0.4 0.742 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼