      건축물 외장 단열재에 따른 발화위험성

      한글로보기

      https://www.riss.kr/link?id=A108906444

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Recently, interest in insulation functional building materials has been increasing to reduce greenhouse gas and increase energy efficiency. However, insulation materials installed in buildings for insulation cause the rapid vertical spread of flames, and it causes difficulties in extinguishing fires, leading to enormous casualties and property damage. Therefore, the purpose of this study is to identify the diffusion characteristics of flames according to the type of insulation and adhesive, and to establish measures to reduce fire damage. To this end, different types of insulation and adhesives were used to compare the diffusion characteristics of flames by simultaneously setting fire. In conclusion, only incombustible insulation had the effect of preventing combustion expansion, and flame retardant insulation and semi-incombustible insulation had minimal effects. And no difference was found according to the type of adhesive. Therefore, it is necessary to revise the current building regulations to restrict the use of combustible insulation materials and to mandate the use of non-combustible insulation materials.
      번역하기

      Recently, interest in insulation functional building materials has been increasing to reduce greenhouse gas and increase energy efficiency. However, insulation materials installed in buildings for insulation cause the rapid vertical spread of flames, ...

      Recently, interest in insulation functional building materials has been increasing to reduce greenhouse gas and increase energy efficiency. However, insulation materials installed in buildings for insulation cause the rapid vertical spread of flames, and it causes difficulties in extinguishing fires, leading to enormous casualties and property damage. Therefore, the purpose of this study is to identify the diffusion characteristics of flames according to the type of insulation and adhesive, and to establish measures to reduce fire damage. To this end, different types of insulation and adhesives were used to compare the diffusion characteristics of flames by simultaneously setting fire. In conclusion, only incombustible insulation had the effect of preventing combustion expansion, and flame retardant insulation and semi-incombustible insulation had minimal effects. And no difference was found according to the type of adhesive. Therefore, it is necessary to revise the current building regulations to restrict the use of combustible insulation materials and to mandate the use of non-combustible insulation materials.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 1.1 연구의 배경 및 목적
      • 2. 이론적 배경
      • 2.1 단열재
      • Abstract
      • 1. 서론
      • 1.1 연구의 배경 및 목적
      • 2. 이론적 배경
      • 2.1 단열재
      • 2.2 단열재의 종류
      • 2.3 외장 단열재 공법 종류
      • 3. 화재조사사례
      • 3.1 화재조사사례(1)
      • 3.2 화재조사사례(2)
      • 4. 화재 재현실험
      • 4.1 실험개요
      • 4.2 실험내용 및 방법
      • 4.3 재현실험 결과
      • 5. 결론
      • 5.1 재현실험 결과분석 및 고찰
      • 5.2 화재예방 및 개선방안
      • 참고문헌