      Advanced anticoagulant suction drainage was prepared by anticoagulant coating with the hydrophobic multicomponent heparin conjugates, and named as MCK-Hepafilm (15K). The coating surface was analyzed by the staining test of azure-A and scanning electr...

      Advanced anticoagulant suction drainage was prepared by anticoagulant coating with the hydrophobic multicomponent heparin conjugates, and named as MCK-Hepafilm (15K). The coating surface was analyzed by the staining test of azure-A and scanning electron microscope (SEM), which shows excellent coating effect on silicone as well as PVC. The coating condition of silicone tube was optimized to 3.0 wt% concentration of coating solution and the solvent casting temperature to 35 oC. In vitro anticoagulant effect is confirmed by observation of platelet adhesion, blood coagulation and adhesion of bacteria. Platelet adhesion on coating surface of PVC and silicone drainage tube was remarkably reduced, and completely prevented from whole blood clots of rabbit. The adhered number of Escherichia coil (E. coil) bacteria on coated surface of PVC drainage tube was reduced with 7.2?.0 CFU/cm2 as compared to the non-coated surface of 10.1?.2 CFU/cm2. Rabbit experiment has been carried out for the MCK-Hepafilm (15K) coated suction drainage device. The efficacy of the MCK-Hepafilm coat was examined by measuring the debris weight forming clogging in the tube (MCK-Hepafilm coated & uncoated) and analyzing the change in blood flow pressure through it, over a period of time, after insertion in the abdomen of the rabbit. In the coating tube, the internal resistance of PVC was reduced, and also the debris weight of silicone was reduced to 315.5?.4 mg as compared with non-coated 555.7?0.6 mg. The obtained results indicate the effectiveness of this MCK-Hepafilm (15K) coating technology for blood contacting medical devices including suction drainage devices in improving their hemocompatibility.

      더보기

      참고문헌 (Reference)

      1 "?Polyurethane surface modified by amphiphilic polymers Effects on protein adsorption" 307-315, 2000

      2 "?Heparin coating reduces encrustation of ureteral stent" 507-510, 2002

      3 "?Fluid flow during percutaneous drainage procedures an in vitro study of the effects of fluid viscosity" 165-169, 1993

      4 "?Development of chitosan/polyethylene vinyl acetate co-matrix Controlled release of aspirin-heparin for preventing cadiovascular thrombosis" 375-381, 1997

      5 "?Clogging of drainage catheters quantitative and longitudinal assessment by monitoring intracatheter pressure in catheters and rabbits" 833-838, 2003

      6 "An Introduction to Materials in Medicine" Academic Press ? (?): 297-308, 1997

      7 "-heparin hydrogels as sensor catheter membrane" 63-70, 1991

      1 "?Polyurethane surface modified by amphiphilic polymers Effects on protein adsorption" 307-315, 2000

      2 "?Heparin coating reduces encrustation of ureteral stent" 507-510, 2002

      3 "?Fluid flow during percutaneous drainage procedures an in vitro study of the effects of fluid viscosity" 165-169, 1993

      4 "?Development of chitosan/polyethylene vinyl acetate co-matrix Controlled release of aspirin-heparin for preventing cadiovascular thrombosis" 375-381, 1997

      5 "?Clogging of drainage catheters quantitative and longitudinal assessment by monitoring intracatheter pressure in catheters and rabbits" 833-838, 2003

      6 "An Introduction to Materials in Medicine" Academic Press ? (?): 297-308, 1997

      7 "-heparin hydrogels as sensor catheter membrane" 63-70, 1991

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2005-03-28 학회명변경 한글명 : 생체재료학회 -> 한국생체재료학회
      영문명 : 미등록 -> The Korean Society For Biomaterials
      KCI등재후보
      2005-03-28 학술지등록 한글명 : 생체재료학회지
      외국어명 : Biomaterials Research
      KCI등재후보
      2004-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.32 0.32 0.3
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.26 0.23 0.511 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼