      소음성 난청자의 순음청력역치와 어음청취역치 및 청성뇌간반응 역치와의 비교 = A Comparison among Pure-Tone Thresholds, Speech Reception Threshold, and Auditory Brainstem Response Threshold in Noise-Induced Hearing Loss

      한글로보기

      https://www.riss.kr/link?id=A104029572

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Pure-tone thresholds (PTTs), speech reception threshold (SRT), and auditory brainstem response (ABR) threshold were compared in 100 ears with noise-induced hearing loss to examine the accuracy of prediction for hearing thresholds. The 100 subject ears...

      Pure-tone thresholds (PTTs), speech reception threshold (SRT), and auditory brainstem response (ABR) threshold were compared in 100 ears with noise-induced hearing loss to examine the accuracy of prediction for hearing thresholds. The 100 subject ears, which were with sensorineural hearing loss and no history of ear disease, were selected from 62 male workers who were exposed to noise in automobile manufacturing factory and suspected of noise-induced hearing loss. PTTs were determined using modified ascending method in 5-dB steps by pure tone audiometry (PTA);threshold for speech were measured as SRT;and ABR threshols was defined as the lowest stimulus intensity at which V wave could be clearly observed. SRT was lower than the average PTTs, and ABR threshold was higher than PTTs and SRT. Simple regression analysis was carried out to examine the relationship between SRT and the average PTTs and thresholds by frequency by PTA. PTTs in low frequency region (0.5-1 kHz) showed higher association, with explanatory power of more than 70%, and particularly the average PTTs by three division method showed the highest association with SRT. Simple regression analysis for the relationship between ABR threshold and the average PTTs and thresholds by frequency by PTA revealed that PTTs in 2-6 kHz region was more highly associated with ABR threshold.

      더보기

      참고문헌 (Reference)

      1 김규상, "소음특수건강진단 자료를 이용한 순음청력검사 평가" 32 (32): 30-39, 1999

      2 김규상, "모 자동차제조업체 근로자의 청력-순음청력검사 평가의 일치도" 198 : 11-18, 2004

      3 김규상, "모 자동차 제조업체 근로자의 청력-순음청력검사방법 및 평가의 적정성" 197 : 16-24, 2004

      4 김규상, "모 자동차 제조업체 근로자의 청력-검사기관에 따른 순음청력검사 역치의 차이" 199 : 10-21, 2004

      5 Gorga MP, "Using a combination of click- and tone burst-evoked auditory brain stem response measurements to estimate pure-tone thresholds" 27 (27): 60-74, 2006

      6 Johnson TA, "Threshold prediction using the auditory steady-state response and the tone burst auditory brain stem response: a within-subject comparison" 26 (26): 559-576, 2005

      7 Hone SW, "The use of cortical evoked response audiometry in the assessment of noise-induced hearing loss" 128 (128): 257-262, 2003

      8 Drift JF, "The relation between the pure-tone audiogram and the click auditory brainstem response threshold in cochlear hearing loss" 26 (26): 1-10, 1987

      9 Alberti PW, "Speech pure tone audiometry as a screen for exaggerated hearing loss in industrial claims" 85 (85): 328-331, 1978

      10 Gold S, "Speech discrimination scores at low sensation levels as a possible index of malingering" 21 (21): 137-141, 1981

      1 김규상, "소음특수건강진단 자료를 이용한 순음청력검사 평가" 32 (32): 30-39, 1999

      2 김규상, "모 자동차제조업체 근로자의 청력-순음청력검사 평가의 일치도" 198 : 11-18, 2004

      3 김규상, "모 자동차 제조업체 근로자의 청력-순음청력검사방법 및 평가의 적정성" 197 : 16-24, 2004

      4 김규상, "모 자동차 제조업체 근로자의 청력-검사기관에 따른 순음청력검사 역치의 차이" 199 : 10-21, 2004

      5 Gorga MP, "Using a combination of click- and tone burst-evoked auditory brain stem response measurements to estimate pure-tone thresholds" 27 (27): 60-74, 2006

      6 Johnson TA, "Threshold prediction using the auditory steady-state response and the tone burst auditory brain stem response: a within-subject comparison" 26 (26): 559-576, 2005

      7 Hone SW, "The use of cortical evoked response audiometry in the assessment of noise-induced hearing loss" 128 (128): 257-262, 2003

      8 Drift JF, "The relation between the pure-tone audiogram and the click auditory brainstem response threshold in cochlear hearing loss" 26 (26): 1-10, 1987

      9 Alberti PW, "Speech pure tone audiometry as a screen for exaggerated hearing loss in industrial claims" 85 (85): 328-331, 1978

      10 Gold S, "Speech discrimination scores at low sensation levels as a possible index of malingering" 21 (21): 137-141, 1981

      11 Gorga MP, "Some comparisons between auditory brain stem response thresholds, latencies, and the pure-tone audiogram" 6 (6): 105-112, 1985

      12 Laukli E, "Reproducibility of hearing threshold measurements. Supplementary data on bone-conduction and speech audiometry" 19 (19): 187-190, 1990

      13 Bamford JM, "Pure tone audiograms from hearing-impaired choldren. II. Predicting speech-hearing from the audiogram" 15 (15): 3-10, 1981

      14 Chien CH, "Prediction of the pure-tone average from the speech reception and auditory brainstem response thresholds in a geriatric population" 70 (70): 366-372, 2008

      15 Coren S, "Predicting speech recognition thresholds from pure tone hearing thresholds" 79 (79): 1003-1008, 1994

      16 Picard M, "Manolache M. Speech audiometry in noise-exposed workers: the SRT-PTA relationship revisited" 38 (38): 30-43, 1999

      17 Schlauch RS, "Identification of psuedohypacusis using speech recognition thresholds" 17 (17): 229-236, 1996

      18 Beattie RC, "Frequency-specific auditory brainstem responses in adults with sensorineural hearing loss" 35 (35): 194-203, 1996

      19 Rickards FW, "Exaggerated hearing loss in noise induced hearing loss compensation claims in Victoria" 163 (163): 360-363, 1996

      20 Alberti PW, "Exaggerated hearing loss in compensation claimants" 16 (16): 362-366, 1987

      21 Sulkowski W, "Electric response audiometry and compensational noiseinduced hearing loss" 48 (48): 370-374, 1994

      22 Wang YF, "Confirming pure-tone thresholds by auditory brainstem response in the geriatric population" 65 (65): 164-171, 2002

      23 Kodera K, "Brain stem response audiometry at speech frequencies" 16 (16): 469-479, 1977

      24 Hyde M, "Auditory evoked potentials in audiometric assessment of compensation and medicolegal patients" 95 (95): 514-519, 1986

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2015-12-28 학술지명변경 한글명 : 청능재활 -> Audiology and Speech Research
      외국어명 : Audiology -> Audiology and Speech Research
      KCI등재
      2013-01-01 평가 등재학술지 선정 (등재유지) KCI등재
      2012-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2010-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2007-03-08 학회명변경 한글명 : 한국청각학회 -> 한국청각언어재활학회
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.54 0.54 0.58
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.47 0.43 0.607 0.44
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼