1 Burguete RL, "Tightening characteristics for screwed joints in osseointegrated dental implants" 71 : 592-599, 1994
2 Patterson EA, "Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants" 7 : 26-34, 1992
3 Binon P, "The role of screws in implant systems" 9 (9): 48-, 1994
4 Griffith HT, "Suggested tightening torques for structural bolts. Fastener Technology/February 1087. In:Torque Tensioning: A Ten Part Compilation. Stow, OH:Fastener Technology, Jan- Dec"
5 Binon P, "Screw joints, components, and other intimate relationships" 72 : 625-, 1994
6 Cavazos E, "Preventing loosening of implant abutment screws" 75 : 566-569, 1996
7 Bränemark P-I, "Osseointegrated implants in the treatment of the edentulous jaw: Experience from a ten year period" 11 (11): 1977
8 Sakaguchi RL, "Nonlinear contact analysis of preload in dental implant screws" 10 : 295-302, 1995
9 Levine RA, "Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Preliminary results at 6 or more months of loading" 12 : 237-242, 1997
10 Merz BR, "Mechanics of the implant-abutment connection. An 8-degree taper compared to a butt joint connection" 15 : 519-526, 2000
1 Burguete RL, "Tightening characteristics for screwed joints in osseointegrated dental implants" 71 : 592-599, 1994
2 Patterson EA, "Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants" 7 : 26-34, 1992
3 Binon P, "The role of screws in implant systems" 9 (9): 48-, 1994
4 Griffith HT, "Suggested tightening torques for structural bolts. Fastener Technology/February 1087. In:Torque Tensioning: A Ten Part Compilation. Stow, OH:Fastener Technology, Jan- Dec"
5 Binon P, "Screw joints, components, and other intimate relationships" 72 : 625-, 1994
6 Cavazos E, "Preventing loosening of implant abutment screws" 75 : 566-569, 1996
7 Bränemark P-I, "Osseointegrated implants in the treatment of the edentulous jaw: Experience from a ten year period" 11 (11): 1977
8 Sakaguchi RL, "Nonlinear contact analysis of preload in dental implant screws" 10 : 295-302, 1995
9 Levine RA, "Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Preliminary results at 6 or more months of loading" 12 : 237-242, 1997
10 Merz BR, "Mechanics of the implant-abutment connection. An 8-degree taper compared to a butt joint connection" 15 : 519-526, 2000
11 Schwarz MS, "Mechanical complications of dental implants" 11 (11): 156-158, 2000
12 Jörnéus L, "Loads and designs of screw joints for single crowns supported by osseointegrated implants" 7 : 353-359, 1992
13 Rangert B, "Load and designs of screw joints for single crowns supported by osseointegrated implants" 4 : 241-247, 1989
14 Gibb CH, "Limits of human bite strength" 56 : 226-229, 1986
15 Rangert B, "Learning from history The transition from full arch to posterior partial restorations" 9 (9): 67-, 1995
16 Binon P, "Implants and components: Entering the new millennium" 15 : 76-94, 2000
17 Keson BT, "Implant-abutment screw joint preload of 7 hex-top abutment systems" 16 : 367-377, 2001
18 McGlumphy EA, "Implant Screw Mechanics" 42 : 71-89, 1998
19 Rangert B, "Forces and moments on Branemark implants" 4 : 241-247, 1989
20 Lang L.A, "Finite element analysis to determine implant preload" 90 : 539-546, 2003
21 Khraisat A, "Fatigue resistance of two implant/ abutment joint designs" 88 : 604-610, 2002
22 Sakaguchi RL, "External strain distribution on implant prosthetic components" 73 : 232-, 1994
23 Cibirka RM, "Examination of the implant-abutment interface after fatigue testing" 85 : 268-275, 2001
24 Haack JE, "Elongation and preload stress in dental implant abutment screws" 10 : 529-536, 1995
25 ISO, "Dental implants Dynamic continuous fatigue test" International Organization for Standardization 2001
26 Lazzara RJ, "Criteria for implant selection: surgical and prosthetic consideration" 6 : 55-62, 1994
27 Jaarda MJ, "Comparison of “look-alike”implant prosthetic retaining screws" 4 : 23-27, 1995
28 Helsingen A, "Comparative stress analysis and clinical performance studies of Bränemark implants and related clones" 9 : 422-430, 1994
29 Felton DA, "Cemented versus screw-retained implant prostheses: which is better? [current issues forum]" 14 : 138-139, 1999
30 Mengel R, "An in vitro study of the treatment of implant surfaces with different insturments" 13 : 91-96, 1998
31 Norton MR, "An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design" 8 : 290-298, 1997
32 Bickford JH, "An Introduction to the Design and Behavior of Bolted Joints" New York Marcel Dekker 515-564, 1995
33 Levine RA, "A multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Results of loading for 2 or more years" 14 : 516-520, 1999
34 Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw" 10 : 387-416, 1981