RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재후보 SCIE SCOPUS

      AC and DC Applications of Induction Generator Excited by Static VAR Compensator

      한글로보기

      https://www.riss.kr/link?id=A76032117

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This paper presents the steady-state analysis of the three-phase self-excited induction generator (SEIG). The three-phase SEIG with a squirrel cage rotor is driven by a variable-speed prime mover (VSPM) or a constant-speed prime mover (CSPM) such as a...

      This paper presents the steady-state analysis of the three-phase self-excited induction generator (SEIG). The three-phase SEIG with a squirrel cage rotor is driven by a variable-speed prime mover (VSPM) or a constant-speed prime mover (CSPM) such as a wind turbine or a micro gas turbine. Furthermore, a PI closed-loop feedback voltage regulation scheme of the three-phase SEIG driven by a VSPM on the basis of the static VAR compensator (SVC) is designed and evaluated for the stand-alone AC and DC power applications. The simulation and experimental results prove the practical effectiveness of the additional SVC with the PI controller-based feedback loop in terms of its fast responses and high performances

      더보기

      목차 (Table of Contents)

      • ABSTRACT
      • 1.Introduction
      • 2.System Description
      • 3.Variable-Speed Prime Mover Characteristics
      • 4.Static VAR Control with PI Controller for Three-Phase SEIG Voltage Regulation
      • ABSTRACT
      • 1.Introduction
      • 2.System Description
      • 3.Variable-Speed Prime Mover Characteristics
      • 4.Static VAR Control with PI Controller for Three-Phase SEIG Voltage Regulation
      • 5.Steady State Analysis of Three-Phase SEIG with Static VAR Compensator
      • 6.Simulation and Experimental Results
      • 7.Conclusions
      • Appendix
      • References
      더보기

      참고문헌 (Reference)

      1 "Voltage-Frequency Control of A Self-Excited Induction generator" 14 (14): 394-401, 1999

      2 "Various Induction Generator Schemes for Wind-Electricity Generation" 23 : 71-83, 1992

      3 "Static VAR Compensator Models for Power Flow and Dynamic Performance Simulation" 9 (9): 1994.

      4 "Static Exciters for Induction Generator" ia-13 (ia-13): 1977-, /0910

      5 "Solid State Control of Wind-Driven Self-Excited Induction Generator" 23 : 571-582, 1995

      6 "Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations" 3-a (3-a): 17-34, 2003

      7 "Induction generator Controller Based on the Instantaneous Reactive Power Theory" 17 (17): 368-373, 2002

      8 "Effects of Long-Shunt and Short-Shunt Connections on Voltage Variations of A Self-Excited Induction Generator" 12 (12): 368-374, 1997

      9 "Capacitance Requirement for Isolated Self-Excited Induction Generator" 137 (137): 154-159, 1990.

      10 "An Alternative Isolated Wind Electric Pumping System Using Induction Machines" 14 (14): 1611-1616, 1999

      1 "Voltage-Frequency Control of A Self-Excited Induction generator" 14 (14): 394-401, 1999

      2 "Various Induction Generator Schemes for Wind-Electricity Generation" 23 : 71-83, 1992

      3 "Static VAR Compensator Models for Power Flow and Dynamic Performance Simulation" 9 (9): 1994.

      4 "Static Exciters for Induction Generator" ia-13 (ia-13): 1977-, /0910

      5 "Solid State Control of Wind-Driven Self-Excited Induction Generator" 23 : 571-582, 1995

      6 "Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations" 3-a (3-a): 17-34, 2003

      7 "Induction generator Controller Based on the Instantaneous Reactive Power Theory" 17 (17): 368-373, 2002

      8 "Effects of Long-Shunt and Short-Shunt Connections on Voltage Variations of A Self-Excited Induction Generator" 12 (12): 368-374, 1997

      9 "Capacitance Requirement for Isolated Self-Excited Induction Generator" 137 (137): 154-159, 1990.

      10 "An Alternative Isolated Wind Electric Pumping System Using Induction Machines" 14 (14): 1611-1616, 1999

      11 "A Technique for The Steady state Analysis of Self-Excited Induction Generator with Variable Speed" 8 (8): 1993-, 12

      12 "A New Technique for Analysis of Self-Excited Induction Generator" 23 : 647-656, 1995

      13 "A 4-kW 42-V Induction-Machine-Based Automotive Power Generation System With a Diode Bridge Rectifier and a PWM Inverter" 39 (39): 1287-1293, 2003

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2014-10-08 학술지명변경 한글명 : 전력전자학회 영문논문지 -> Journal of Power Electronics KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2004-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.83 0.54 0.74
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.65 0.62 0.382 0.06
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼