RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      Constructing a digital twin for estimating the response and load of a piping system subjected to seismic and arbitrary loads

      한글로보기

      https://www.riss.kr/link?id=A108545789

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In recent years, technological developments have rapidly increased the number of complex structures and equipment in the industrial. Accordingly, the prognostics and health monitoring (PHM) technology has become significant. The safety assessment of i...

      In recent years, technological developments have rapidly increased the number of complex structures and equipment in the industrial. Accordingly, the prognostics and health monitoring (PHM) technology has become significant. The safety assessment of industrial sites requires data obtained by installing a number of sensors in the structure. Therefore, digital twin technology, which forms the core of the Fourth Industrial Revolution, is attracting attention in the safety field. The research on digital twin technology of structures subjected to seismic loads has been conducted recently. Hence, this study proposes a digital twin system that estimates the responses and arbitrary load in real time by utilizing the minimum sensor to a pipe that receives a seismic and arbitrary load. To construct the digital twin system, a finite-element model was created considering the dynamic characteristics of the pipe system, and then updating the finite-element model. In addition, the calculation speed was improved using a finite-element model that applied the reduced-order modeling (ROM) technology to achieve real-time performance. The constructed digital twin system successfully and rapidly estimated the load and the point where the sensor was not attached. The accuracy of the constructed digital twin system was verified by comparing the response of the digital twin model with that derived by using the load estimated from the digital twin model as input in the finite-element model.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼