      자궁경부세포진에 있어서 AutoPap 300 QC System의 임상경험과 민감도 검사 = Clinical Experience and Sensitivity of the AutoPap 300 QC System in Cervicovaginal Cytology

      한글로보기

      https://www.riss.kr/link?id=A101691444

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      OBJECTIVE: False negatives of cervical smears due to screening errors pose a significant and persistent problem. AutoPap 300 QC System, an automated screening device, is designed to rescreen conventionally prepared Pap smears initially screened by cyt...

      OBJECTIVE: False negatives of cervical smears due to screening errors pose a significant and persistent problem. AutoPap 300 QC System, an automated screening device, is designed to rescreen conventionally prepared Pap smears initially screened by cytotechnologists as normal. Clinical experience and sensitivity of the AutoPap 300 QC System were assessed and compared with current 10% random qualify control technique. MATERIALS AND METHODS: In clinical practice, a total of 18,592 "within normal limits" or "benign cellular changes" cases classified by The Bethesda System were rescreened by the Autopap System. In study for sensitivity of The AutoPap System to detect false negatives, a total of 1,680 "within normal limits" or "benign cellular changes" cases were rescreened both manually and by the AutoPap System. The sensitivity of the AutoPap System to these false negatives was assessed at 10% review rate to compare 10% random manual rescreen. RESULTS: In clinical practice, 38 false negatives were identified by the AutoPap System and we had achieved 0.2% reduction in the false negative rate of screening error. In study for sensitivity, 37 false negatives were identified by manual rescreening, and 23 cases(62.2%) of the abnormal squamous cytology were detected by the AutoPap System at 10% review rate. CONCLUSONS: The AutoPap 300 QC System is a sensitive automated rescreening device that can detect potential false negatives prior to reporting and can reduce false negative rates in the laboratory. The device is confirmed to be about eight times superior to the 10% random rescreen in detecting false negatives.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼