1 강종우, "원위 요골 골절의 합병증" 대한정형외과학회 48 (48): 165-174, 2013
2 Tarallo L, "Volar plate fixation for the treatment of distal radius fractures : analysis of adverse events" 27 : 740-745, 2013
3 Thomas AD, "Use of fluoroscopy in determining screw overshoot in the dorsal distal radius : a cadaveric study" 34 : 258-261, 2009
4 Benson EC, "Two potential causes of EPL rupture after distal radius volar plate fixation" 451 : 218-222, 2006
5 Vaiss L, "The utility of the fluoroscopic skyline view during volar locking plate fixation of distal radius fractures" 3 : 245-249, 2014
6 Wall LB, "The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates" 37 : 446-453, 2012
7 Brunner A, "The dorsal tangential X-ray view to determine dorsal screw penetration during volar plating of distal radius fractures" 40 : 27-33, 2015
8 Granville-Chapman J, "The distal radius skyline view: validation of a new technique for determining dorsal screw penetration in locked volar plating of the distal radius" 94 (94): 16-, 2012
9 Ganesh D, "The detection of prominent hardware in volar locked plating of distal radius fractures : intraoperative fluoroscopy versus computed tomography" 30 : 618-621, 2016
10 Ozer K, "Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating" 6 : 190-193, 2011
1 강종우, "원위 요골 골절의 합병증" 대한정형외과학회 48 (48): 165-174, 2013
2 Tarallo L, "Volar plate fixation for the treatment of distal radius fractures : analysis of adverse events" 27 : 740-745, 2013
3 Thomas AD, "Use of fluoroscopy in determining screw overshoot in the dorsal distal radius : a cadaveric study" 34 : 258-261, 2009
4 Benson EC, "Two potential causes of EPL rupture after distal radius volar plate fixation" 451 : 218-222, 2006
5 Vaiss L, "The utility of the fluoroscopic skyline view during volar locking plate fixation of distal radius fractures" 3 : 245-249, 2014
6 Wall LB, "The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates" 37 : 446-453, 2012
7 Brunner A, "The dorsal tangential X-ray view to determine dorsal screw penetration during volar plating of distal radius fractures" 40 : 27-33, 2015
8 Granville-Chapman J, "The distal radius skyline view: validation of a new technique for determining dorsal screw penetration in locked volar plating of the distal radius" 94 (94): 16-, 2012
9 Ganesh D, "The detection of prominent hardware in volar locked plating of distal radius fractures : intraoperative fluoroscopy versus computed tomography" 30 : 618-621, 2016
10 Ozer K, "Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating" 6 : 190-193, 2011
11 ill BW, "Dorsal screw penetration with the use of volar plating of distal radius fractures: how can you best detect" 29 : e408-e413, 2015
12 Al-Rashid M, "Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures" 88 : 1610-1612, 2006
13 Arora R, "Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate" 21 : 316-322, 2007
14 Ozer K, "Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius" 37 : 963-967, 2012
15 Rhee PC, "Avoiding and treating perioperative complications of distal radius fractures" 28 : 185-198, 2012
16 McKay SD, "Assessment of complications of distal radius fractures and development of a complication checklist" 26 : 916-922, 2001
17 Riddick AP, "Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixation" 37 : 407-411, 2012
18 Downing ND, "A revolution in the management of fractures of the distal radius" 90 : 1271-1275, 2008