RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      The Effect of Whole Body Vibration Exercise on Ankle Joint Spasticity Patients with Chronic Stroke = The Effect of Whole Body Vibration Exercise on Ankle Joint Spasticity Patients with Chronic Stroke

      한글로보기

      https://www.riss.kr/link?id=A105593012

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: This study aimed to determine the appropriate stimulus strength that could result in a positive effect on the ankle joint spasticity when patients with chronic stroke performed whole body vibration (WBV) exercise. Methods: Among 72 patients w...

      Purpose: This study aimed to determine the appropriate stimulus strength that could result in a positive effect on the ankle joint spasticity when patients with chronic stroke performed whole body vibration (WBV) exercise.
      Methods: Among 72 patients who were diagnosed with stroke at least 6 months ago, those able to perform a half squat pose with ambulation issues due to ankle joint spasticity (modified Ashworth scale, MAS≥2) were included for analysis. Individuals participated in four different frequencies of vertical WBV exercise; 0 Hz, 10 Hz, 20 Hz, and 30 Hz. Vibration amplitude was 3-4 mm and 5 minutes WBV exercise was performed at each frequency, followed by a measurement after 2-minute rest. We assigned 18 individuals to each frequency and asked them to participate in the WBV exercise once every 3 weeks. The level of spasticity was evaluated by visual analogue scale (VAS) for self-assessment. The myoton PRO was utilized to objectively evaluate the level of spasticity and check the muscle tone and stiffness.
      Results: Participants showed 0 Hz VAS was a significant difference between 20 Hz application conditions (p<0.05). Muscle tone was significantly different at 0 Hz between 20 Hz, and 30 Hz (p<0.05), significantly difference at 10 Hz between 30 Hz (p<0.05). Muscle stiffness significantly difference at 0 Hz between 20 Hz, and 30 Hz (p<0.05), significantly difference at 10 Hz between 20 Hz, and 30 Hz (p<0.05).
      Conclusion: Findings of this study show that the frequency of more than 20 Hz was effective in improving the ambulatory ability in patients with chronic stroke. Currently, the effective WBV protocol is limited. Hence, this study was designed to suggest an effective WBV protocol to improve neuromodulation ability for chronic stroke patients.