RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재후보 SCOPUS SCIE

      퇴행성 경추증의 경추전방고정술에서 비잠금 단피질 및 양피질 나사못 사용의 비교 = Comparision of Non-locking Monocortical and Bicortical Screw System for Anterior Cervical Fusion and Plating in Degenerative Cervical Spondylosis

      한글로보기

      https://www.riss.kr/link?id=A104743010

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Objective : Non-locking bicortical screw and locking monocortical screw system have usually been used in anterior cervical spine fusion and plating. The purpose of this study is to evaluate the differences in stability and safety between the non-locki...

      Objective : Non-locking bicortical screw and locking monocortical screw system have usually been used in
      anterior cervical spine fusion and plating. The purpose of this study is to evaluate the differences in stability and
      safety between the non-locking bicortical and monocortical screw-plate system.
      Methods : The authors reviewed 135 cervical spondylotic patients who underwent anterior cervical fusion from Jan.
      1995 through Jun. 2002. The patients were separated into two groups : Group 1. consisted of 68 patients (male : 55,
      female 13 and mean age : 50.5years) treated with non-locking bicortical screw system, Group 2. consisted of 67
      patients (male 50, female 17, mean age : 59.6 years) treated with non-locking monocortical screw system. The mean
      follow-up duration was 50 months (from 9 to 101 months). A comprehensive evaluation between two groups were
      made.
      Results : There were no graft material related complications in both groups. But instrument related complications were
      1 case of screw breakage and 1 case of screw loosening in group 1 and 1 case of screw loosening in group 2. Mean
      time for plate and screw fixation was less required in group 2 than group 1. Fusion had occurred in all patients of both
      groups.
      Conclusion : Non-locking monocortical screw fixation can be recommended for anterior cervical fusion and
      plating in degenerative disease, making the procedure quicker, easier, and safer compare with non-locking
      bicortical screw.

      더보기

      참고문헌 (Reference)

      1 "Theeffects of plate stabilization on maintenance of interspace height inpatients with lower cervical lesion umderwent anterior cervicalinterbody fusion" 28 : 683-692, 1999

      2 "The treatment of certain spine disorders byanterior removal of the intervertebral disc and interbody fusion" 40A : 624-626, 1958

      3 "The efficacy of the unicortical screw inthe anterior cervical fusion of the degenerative cervical spine disease" 27 : 612-618, 1998

      4 "The effect of locking fixationscrews on the stability of anterior cervical plating" 24 : 334-338, 1999

      5 "The anterior cervical plate" 8 : 700-707, 1983

      6 "Outcomeanalysis of the patients with and without anterior plating in multi-leveldegenerative cervical diseases" 30 : 1369-1374, 2001

      7 "Osteosintesis en las fractures de requiscervical" 14 : 285-288, 1977

      8 "Long-term follow-upresults of anterior cervical interbody fusion with and without cervicalplate" 26 : 535-541, 1997

      9 "Long-term effects on the cervical spine after anterior lockingplate fixation" 30 : 493-500, 2001

      10 "Factorsaffecting the pullout strength of self-drilling and self-tapping anteriorcervical screws" 28 : 9-13, 2003

      1 "Theeffects of plate stabilization on maintenance of interspace height inpatients with lower cervical lesion umderwent anterior cervicalinterbody fusion" 28 : 683-692, 1999

      2 "The treatment of certain spine disorders byanterior removal of the intervertebral disc and interbody fusion" 40A : 624-626, 1958

      3 "The efficacy of the unicortical screw inthe anterior cervical fusion of the degenerative cervical spine disease" 27 : 612-618, 1998

      4 "The effect of locking fixationscrews on the stability of anterior cervical plating" 24 : 334-338, 1999

      5 "The anterior cervical plate" 8 : 700-707, 1983

      6 "Outcomeanalysis of the patients with and without anterior plating in multi-leveldegenerative cervical diseases" 30 : 1369-1374, 2001

      7 "Osteosintesis en las fractures de requiscervical" 14 : 285-288, 1977

      8 "Long-term follow-upresults of anterior cervical interbody fusion with and without cervicalplate" 26 : 535-541, 1997

      9 "Long-term effects on the cervical spine after anterior lockingplate fixation" 30 : 493-500, 2001

      10 "Factorsaffecting the pullout strength of self-drilling and self-tapping anteriorcervical screws" 28 : 9-13, 2003

      11 "Evaluation of anew monocortical screw for anterior cervical fusion and plating by acombined biomechanical and clinical study" 8 : 382-387, 1999

      12 "Economical analysis of cervicaldisc disease by anterior inter-body fusion methods-Comparing of BoneGraft vs Plating" 30 : 201-206, 2001

      13 "Die vordere Verplattung derHalswirbelsaule mit dem Hohlschrauben-Plattensystem aus Titanium" 57 : 702-707, 1986

      14 "Comparative efficacy studybetween monocortical and bicortical screws in anterior cervical fusion" 27 : 599-605, 1998

      15 "Clinicalcomparison of anterior cervical plating system in acute cervical injury" 27 : 1230-1234, 1998

      16 "Cervical spondylosis:the role of anteriorinstrumentation after decompression and fusion" 14 : 10-16, 2001

      17 "Centralcorpectomy for cervical spondylotic myelopathy:a consecutive serieswith long-term follow-up evaluation" 74 : 163-170, 1991

      18 "Biomechanical evaluation of subcortical versus bicorticalscrew purchase in anterior cervical plating" 138 : 167-173, 1996

      19 "Biomechanical evaluation of anterior cervical spine stabilization" 23 : 886-892, 1998

      20 "Biomechanical evaluation of Caspar and cervical spine locking platesystems in a cadaveric model" 84 : 1039-1045, 1996

      21 "Assessment ofunicortical and bicortical fixation in a quasistatic cadaveric model.Role of bone mineral density and screw torque" 20 : 1861-1867, 1995

      22 "Anteriorcervical interbody fusion : Comparison study between simple fusion,locked and non-locked plating systems" 28 : 347-353, 1999

      23 "Anterior plate stabilization for fracturedislocationsof the lower cervical spine" 20 : 203-205, 1980

      24 "Anterior cervical plating enhances arthrodesis after discectomy andfusion with cortical allograft" 50 : 229-238, 2002

      25 "Anterior cervical platestabilization in one-and two-level degenerative disease : Overtreatmentor Benefit?" 11 : 1-11, 1998

      26 "Anterior cervical fusion with or without platesafter discectomy in cervical spondylosis" 28 : 823-828, 1999

      27 "Anterior cervical fusion andCaspar plate stabilization for cervical trauma" 25 : 491-502, 1989

      28 "Anterior approach for removal of ruptured cervical disc" 16 : 602-617, 1958

      29 "Analysis of noninstrumented anterior cervicaldiscectomy and interbody fusion in degenerative cervical disease" 30 : 180-185, 2001

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2005-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.66 0.1 0.49
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.4 0.34 0.374 0.04
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼