RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      치과 임플랜트 보철에 있어 경사지대주의 경사각에 따른 응력의 유한요소법적 분석 = A STUDY ON THE TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS INDUCED BY THE ANGULATION OF ANGULATED IMPLANT ABUTMENT IN IMPLANT PROSTHESIS

      한글로보기

      https://www.riss.kr/link?id=A19581538

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The purpose of this study was to evaluate and compare the stress distribution in the implant and bony tissue according to the different angulations of angulated abutment. Nine finite element models with different angulations (0˚, 5˚, 10˚, 15˚, 20�...

      The purpose of this study was to evaluate and compare the stress distribution in the implant and bony tissue according to the different angulations of angulated abutment. Nine finite element models with different angulations (0˚, 5˚, 10˚, 15˚, 20˚, 25˚, 30˚, 35˚, 40˚) were designed. Two dimensional finite element analysis was used for this study.
      The results were as follows
      1. All the tested angulated abutment demonstrated maximum stress value at the cervical portion of implant in the interface A and B.
      2. Zero-degree angulated abutment showed less stress value than any others.
      3. The Angulated abutments with 5 degree and 10 degree demonstrated higher stress concentration than that with zero degree in interface A and B. The abutments over 20 degree showed very high stress value at the opposite site of angulated cervical portion.
      4. The augulated abutments over 30 degree showed very large stress distribution inside of implant fixture.
      5. The agulated abutment with 15, 20 and 25 degree showed low stress value at the angulated cervical portion. But the stress increased in the angulated abutment over 30 degree.
      6. The angulated abutment over 30 degree demonstrated severe stress concentration at the opposite site of angulated cervical portion.
      7. From the view point of stress distribution, the use of abutments more than 30˚ angulation seem to be very disadvantageous.

      더보기

      목차 (Table of Contents)

      • Ⅰ. 서 론
      • Ⅱ. 연구재료 및 방법
      • Ⅲ. 연구결과
      • Ⅳ. 총괄 및 고안
      • Ⅴ. 결 론
      • Ⅰ. 서 론
      • Ⅱ. 연구재료 및 방법
      • Ⅲ. 연구결과
      • Ⅳ. 총괄 및 고안
      • Ⅴ. 결 론
      • 참고문헌
      • 영문초록
      • 사진부도
      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼