RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCIE SCOPUS

      Corrosion mitigation of steel rebars in chloride contaminated concrete pore solution using inhibitor: An electrochemical investigation

      한글로보기

      https://www.riss.kr/link?id=A107463151

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P><B>Abstract</B></P> <P>Inhibitor is one of the most accepted method to reduce, prolong the initiation of steel corrosion and increase the threshold value of Cl<SUP>−</SUP> and CO<SUB>3</SUB&...

      <P><B>Abstract</B></P> <P>Inhibitor is one of the most accepted method to reduce, prolong the initiation of steel corrosion and increase the threshold value of Cl<SUP>−</SUP> and CO<SUB>3</SUB> <SUP>2−</SUP> ions. In present study, we have mixed sodium salt of phosphate and benzoate along with benzo triazole in water to prepare the inhibitor. Open circuit potential (OCP) results show that 5 v/v% inhibitor was exhibited most positive (nobler) potential than others at its prolonged exposure in simulated concrete pore (SCP) + 3.5 wt% NaCl solution. The OCP of 3 and 5% inhibitor containing solution proved that these concentrations are away from under corrosion region of steel rebar even after 192 h of exposure in SCP + 3.5 wt% NaCl solution. Electrochemical impedance spectroscopy (EIS) results show that the charge transfers resistance (R<SUB>ct</SUB>) to be highest for 5% inhibitor and gradually decreased once the concentration was reduced with exposure periods. Potentiodynamic studies reveal that inhibitor shows passive properties due to adsorption of inhibitor molecules on steel surface and enhance the corrosion resistance properties. The efficiency was calculated using R<SUB>ct</SUB> and corrosion current density (I<SUB>corr</SUB>) process and found that 3 and 5% inhibitor exhibit around 89 and 96%, respectively after 1 h of exposure in SCP + 3.5 wt% NaCl solution.</P> <P><B>Highlights</B></P> <P> <UL> <LI> The prepared inhibitor has worked effectively to reduce the corrosion of steel. </LI> <LI> Synthesized inhibitor work as anodic inhibitor. </LI> <LI> High concentration of inhibitor is required to mitigate the corrosion of steel. </LI> <LI> 96% efficiency was found for 5 v/v% inhibitor after 1 h of exposure. </LI> </UL> </P>

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼