RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCI SCIE SCOPUS

      Spatial Resolution and Blurring Artifacts in Digital X-ray Tomosynthesis

      한글로보기

      https://www.riss.kr/link?id=A107450779

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>Digital tomosynthesis (DTS) is an X-ray imaging technique that produces cross-sectional images with a scanning motion in narrow angular ranges. This method is promising for the inspection of internal defects in thin slab objects, such as printed circuit boards. However, this limited angular scan approach can have limited resolution in the depth direction. In addition, it can cause ghosting artifacts that originate from other planes in the reconstructed plane. In this paper, we characterized the imaging performance of a DTS method that uses the filtered backprojection for reconstruction. Various imaging parameters were examined, such as the total scan angle and the number of projections used for the reconstruction. We analyzed the signal and noise characteristics of the reconstructed images obtained for a thin tungsten wire and a thin aluminum disc. We obtained in-plane and in-depth modulation transfer functions (MTFs) from the reconstructed wire response images. From the reconstructed disc response images, we calculated the signal difference between the disc region and the adjacent background region along the depth direction, which is called the artifact spread function (ASF). A narrow angular scan enhances the in-plane MTF performance compared to that obtained from the conventional computed tomography, but it degrades the in-depth MTF performance (i.e., it decreases the depth resolution). In addition, the narrow angular scan degrades the ASF performance and causes severe out-of-plane blur artifacts. The optimal scanning angular range is, therefore, required to obtain tomographic images with high spatial resolution and less blur artifacts. The analysis method performed in this paper could be useful for this optimization.</P>
      번역하기

      <P>Digital tomosynthesis (DTS) is an X-ray imaging technique that produces cross-sectional images with a scanning motion in narrow angular ranges. This method is promising for the inspection of internal defects in thin slab objects, such as prin...

      <P>Digital tomosynthesis (DTS) is an X-ray imaging technique that produces cross-sectional images with a scanning motion in narrow angular ranges. This method is promising for the inspection of internal defects in thin slab objects, such as printed circuit boards. However, this limited angular scan approach can have limited resolution in the depth direction. In addition, it can cause ghosting artifacts that originate from other planes in the reconstructed plane. In this paper, we characterized the imaging performance of a DTS method that uses the filtered backprojection for reconstruction. Various imaging parameters were examined, such as the total scan angle and the number of projections used for the reconstruction. We analyzed the signal and noise characteristics of the reconstructed images obtained for a thin tungsten wire and a thin aluminum disc. We obtained in-plane and in-depth modulation transfer functions (MTFs) from the reconstructed wire response images. From the reconstructed disc response images, we calculated the signal difference between the disc region and the adjacent background region along the depth direction, which is called the artifact spread function (ASF). A narrow angular scan enhances the in-plane MTF performance compared to that obtained from the conventional computed tomography, but it degrades the in-depth MTF performance (i.e., it decreases the depth resolution). In addition, the narrow angular scan degrades the ASF performance and causes severe out-of-plane blur artifacts. The optimal scanning angular range is, therefore, required to obtain tomographic images with high spatial resolution and less blur artifacts. The analysis method performed in this paper could be useful for this optimization.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼