RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      Accelerating knee MR imaging: Compressed sensing in isotropic three-dimensional fast spin-echo sequence

      한글로보기

      https://www.riss.kr/link?id=A107448350

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P><B>Abstract</B></P> <P><B>Purpose</B></P> <P>To compare image quality between compressed sensing (CS)-3D-fast spin-echo (FSE) and conventional 3D-FSE sequences for knee magnetic resonance imagi...

      <P><B>Abstract</B></P> <P><B>Purpose</B></P> <P>To compare image quality between compressed sensing (CS)-3D-fast spin-echo (FSE) and conventional 3D-FSE sequences for knee magnetic resonance imaging (MRI).</P> <P><B>Methods</B></P> <P>Knee MRI of 43 patients (male:female, 14:29; mean age, 53years) were acquired using conventional and CS-3D-FSE with an acceleration factor of 1.5. Overall image quality was assessed by correlation coefficient, root-mean-square error (RMSE), and structural similarity (SSIM) index. Regional image quality was evaluated using signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs). Subjective image quality was evaluated using a four-point scale. Diagnostic agreement for meniscal lesions between the two sequences was evaluated.</P> <P><B>Results</B></P> <P>The scan time was reduced from 7:14–8:08 to 4:53–5:08 with CS. A strong positive correlation was observed between data of the two sequences (mean r=0.880). The RMSE (mean, 126.861) and SSIM index (mean, 0.987) were acceptable. The SNRs and CNRs were not significantly different between the two sequences (<I>P</I> >0.05, each). There were no significant differences in the evaluation of the menisci and cruciate ligaments, while the CS images demonstrated inferior quality of cartilage–subchondral bone delineation. Diagnostic agreement for meniscal lesions between the two sequences was very good (κ=0.943–1).</P> <P><B>Conclusion</B></P> <P>Compressed sensing-3D-FSE knee MRI produces images of acceptable quality while reducing scan time.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼