In this study, a Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO<sub>2</sub>) sensor with an externally exposed optical cavity is proposed for improving sensitivity. NDIR CO<sub>2</sub> sensors with high performance must use ...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A107944283
2021
-
500
KCI등재후보
학술저널
456-460(5쪽)
0
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
In this study, a Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO<sub>2</sub>) sensor with an externally exposed optical cavity is proposed for improving sensitivity. NDIR CO<sub>2</sub> sensors with high performance must use ...
In this study, a Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO<sub>2</sub>) sensor with an externally exposed optical cavity is proposed for improving sensitivity. NDIR CO<sub>2</sub> sensors with high performance must use a lamp-type infrared (IR) source with a strong IR intensity. However, a lamp-type IR source generates high thermal energy that induces thermal noise, interfering with the accuracy of the CO<sub>2</sub> concentration measure. To solve this problem, the optical cavity of the NDIR CO<sub>2</sub> sensor is exposed to quickly dissipate heat. As a result, the proposed NDIR CO<sub>2</sub> sensor has a shorter warm-up time and a higher sensitivity compared to the conventional NDIR CO<sub>2</sub> sensor.
참고문헌 (Reference)
1 L. Kocsis, "The modified Beer-Lambert law revisited" 51 (51): N91(1)-N91(8), 2006
2 L. Fleming, "Reducing N2O induced cross-talk in a NDIR CO2 gas sensor for breath analysis using multilayer thin film optical interference coatings" 336 : 9-16, 2018
3 J. Wang, "Mid-infrared absorption-spectroscopy-based carbon dioxide sensor network in greenhouse agriculture : Development and deployment" 55 (55): 7029-7036, 2016
4 S.L. Wells, "CO2 technology platform : An important tool for environmental problem solving" 40 (40): 518-527, 2001
5 A. Ortiz Perez, "A wireless gas sensor network to monitor indoor environmental quality in schools" 18 (18): 4345(1)-4345(13), 2018
6 T. V. Dinh, "A review on non-dispersive infrared gas sensors : Improvement of sensor detection limit and interference correction" 231 : 529-538, 2016
7 X. Jia, "A miniaturized, fully integrated NDIR CO2 sensor on-chip" 21 (21): 5347(1)-5347(14), 2012
8 J. Hodgkinson, "A low cost, optically efficient carbon dioxide sensor based on non-dispersive infra-red (NDIR) measurement at 4.2μm" 8439 : 843919-, 2012
9 R. Frodl, "A High-Precision NDIR CO2 gas sensor for automotive applications" 6 (6): 1697-1705, 2006
1 L. Kocsis, "The modified Beer-Lambert law revisited" 51 (51): N91(1)-N91(8), 2006
2 L. Fleming, "Reducing N2O induced cross-talk in a NDIR CO2 gas sensor for breath analysis using multilayer thin film optical interference coatings" 336 : 9-16, 2018
3 J. Wang, "Mid-infrared absorption-spectroscopy-based carbon dioxide sensor network in greenhouse agriculture : Development and deployment" 55 (55): 7029-7036, 2016
4 S.L. Wells, "CO2 technology platform : An important tool for environmental problem solving" 40 (40): 518-527, 2001
5 A. Ortiz Perez, "A wireless gas sensor network to monitor indoor environmental quality in schools" 18 (18): 4345(1)-4345(13), 2018
6 T. V. Dinh, "A review on non-dispersive infrared gas sensors : Improvement of sensor detection limit and interference correction" 231 : 529-538, 2016
7 X. Jia, "A miniaturized, fully integrated NDIR CO2 sensor on-chip" 21 (21): 5347(1)-5347(14), 2012
8 J. Hodgkinson, "A low cost, optically efficient carbon dioxide sensor based on non-dispersive infra-red (NDIR) measurement at 4.2μm" 8439 : 843919-, 2012
9 R. Frodl, "A High-Precision NDIR CO2 gas sensor for automotive applications" 6 (6): 1697-1705, 2006
Selective acetate detection using functional carbon nanotube fiber
Metal-organic frameworks-driven ZnO-functionalized carbon nanotube fiber for NO2 sensor
D-space-controlled graphene oxide hybrid membrane-loaded SnO2 nanosheets for selective H2 detection
학술지 이력
연월일 | 이력구분 | 이력상세 | 등재구분 |
---|---|---|---|
2022 | 평가예정 | 계속평가 신청대상 (계속평가) | |
2021-12-01 | 평가 | 등재후보로 하락 (재인증) | |
2018-01-01 | 평가 | 등재학술지 선정 (계속평가) | |
2017-12-01 | 평가 | 등재후보로 하락 (계속평가) | |
2013-01-01 | 평가 | 등재 1차 FAIL (등재유지) | |
2010-01-01 | 평가 | 등재학술지 유지 (등재유지) | |
2008-01-01 | 평가 | 등재학술지 유지 (등재유지) | |
2005-01-01 | 평가 | 등재학술지 선정 (등재후보2차) | |
2004-01-01 | 평가 | 등재후보 1차 PASS (등재후보1차) | |
2002-07-01 | 평가 | 등재후보학술지 선정 (신규평가) |
학술지 인용정보
기준연도 | WOS-KCI 통합IF(2년) | KCIF(2년) | KCIF(3년) |
---|---|---|---|
2016 | 0.22 | 0.22 | 0.16 |
KCIF(4년) | KCIF(5년) | 중심성지수(3년) | 즉시성지수 |
0.15 | 0.13 | 0.319 | 0.07 |