RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      Assessment of the Electrical Grid System to Accommodate the First Nuclear Power Plant in Bangladesh

      한글로보기

      https://www.riss.kr/link?id=A107841864

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      목차 (Table of Contents)

      • Abstract
      • 1. Introduction
      • 2. Model for evaluation of grid system
      • 3. Assessment of grid system in Bangladesh
      • 4. Probabilistic risk analysis
      • Abstract
      • 1. Introduction
      • 2. Model for evaluation of grid system
      • 3. Assessment of grid system in Bangladesh
      • 4. Probabilistic risk analysis
      • 5. Discussion
      • 6. Conclusion
      • References
      더보기

      참고문헌 (Reference)

      1 F. Vahid, "Statistical Failure Analysis of European Substation Transformers" 2014

      2 K. L. Anaya, "Reactive Power Management and Procurement Mechanisms: Lessons for the Power Potential Project" Energy Policy Research Group, University of Cambridge 2018

      3 B. A. Allaf, "Practical evaluation of frequency response and bias in electrical power systems" 64-, 2010

      4 Lei Guo, "Power transmission risk assessment considering component condition" Springer Science and Business Media LLC 2 (2): 50-58, 2014

      5 M. Khalaquzzaman, "Optimization of periodic testing frequency of a reactor protection system based on a risk-cost model and public risk perception" Elsevier BV 241 (241): 1538-1547, 2011

      6 C. Hultholm, "Optimal reserve operation in Turkey – frequency control and non-spinning reserves" Power-Gen Europe 2015

      7 B. Kirby, "Nuclear Generating Stations and Transmission Grid Reliability" 279-287, 2007

      8 M. Khalaquzzaman, "Long-term sustainable energy supply and mitigation of greenhouse gas emission in Bangladesh" 9 (9): 89-98, 2008

      9 IAEA, "Introducing nuclear power plants into electrical power system of limited capacity:problem and remedial measures" 1987

      10 IAEA, "Interaction of grid characteristics with design and performance of nuclear power plants" 1983

      1 F. Vahid, "Statistical Failure Analysis of European Substation Transformers" 2014

      2 K. L. Anaya, "Reactive Power Management and Procurement Mechanisms: Lessons for the Power Potential Project" Energy Policy Research Group, University of Cambridge 2018

      3 B. A. Allaf, "Practical evaluation of frequency response and bias in electrical power systems" 64-, 2010

      4 Lei Guo, "Power transmission risk assessment considering component condition" Springer Science and Business Media LLC 2 (2): 50-58, 2014

      5 M. Khalaquzzaman, "Optimization of periodic testing frequency of a reactor protection system based on a risk-cost model and public risk perception" Elsevier BV 241 (241): 1538-1547, 2011

      6 C. Hultholm, "Optimal reserve operation in Turkey – frequency control and non-spinning reserves" Power-Gen Europe 2015

      7 B. Kirby, "Nuclear Generating Stations and Transmission Grid Reliability" 279-287, 2007

      8 M. Khalaquzzaman, "Long-term sustainable energy supply and mitigation of greenhouse gas emission in Bangladesh" 9 (9): 89-98, 2008

      9 IAEA, "Introducing nuclear power plants into electrical power system of limited capacity:problem and remedial measures" 1987

      10 IAEA, "Interaction of grid characteristics with design and performance of nuclear power plants" 1983

      11 S. Mason, "Improving maintenance –reducing human error" 2001

      12 R. A. D. Melissa, "Extreme Weather and Climate Vulnerabilities of the Electric Grid : A Summary of Environmental Sensitivity Quantification Methods" Oak Ridge National Lab 2019

      13 IAEA, "Electric Grid Reliability and Interface with Nuclear Power Plants" IAEA 2012

      14 US NRC, "Appendix A to Part 50-General Design Criteria for Nuclear Power Plants"

      15 W. L. Vosloo, "A practical guide to outdoor high voltage insulators" Crown Publications 2004

      16 M. Khalaquzzaman, "A model for estimation of reactor spurious shutdown rate considering maintenance human errors in reactor protection system of nuclear power plants" Elsevier BV 240 (240): 2963-2971, 2010

      17 M. A. Chawdhury, "A New Beginning in Frequency Control for the Bangladesh Power System" 1-5, 2018

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2022 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 학술지명변경 한글명 : 한국동력기계공학회지 -> 동력시스템공학회지
      외국어명 : Journal of the Korean Society for Power System Engineering -> Journal of Power System Engineering
      KCI등재
      2019-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2016-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2012-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2008-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2007-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      2006-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      2004-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.22 0.22 0.21
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.19 0.18 0.334 0.06
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼