      중복도형 인텔리전트빌딩 화재시 연기제어를 통한 피난안전성 확보에 관한 연구

      한글로보기

      https://www.riss.kr/link?id=A100570377

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered ad...

      This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 중복도형 건축물의 화재위험성
      • 3. 초·고층 건축물의 화재사례
      • 4. 국내의 제연설비 관련기준
      • Abstract
      • 1. 서론
      • 2. 중복도형 건축물의 화재위험성
      • 3. 초·고층 건축물의 화재사례
      • 4. 국내의 제연설비 관련기준
      • 5. 화재 시뮬레이션 수행 및 분석
      • 5.1 추가 대응방안과 분석방법
      • 5.2 시뮬레이션 모델링을 위한 입력자료
      • 6. Case 5A의 시뮬레이션 수행결과 분석
      • 6.1 감지기, 출입문 및 배연창의 개방시간 분석
      • 6.2 연기의 확산 및 거동 분석
      • 6.3 측정 장치에 의한 수치해석 결과분석
      • 7. Case 5B의 시뮬레이션 수행결과 분석
      • 7.1 감지기, 출입문 및 배연창의 개방시간 분석
      • 7.2 연기의 확산 및 거동 분석
      • 7.3 측정 장치에 의한 수치해석 결과분석
      • 8. 화재시뮬레이션 수행결과의 고찰
      • 9. 결론
      • 10. References
      더보기

      참고문헌 (Reference)

      1 민세홍, "외장재에 의한 동시다발적인 화재의 피난위험성에 관한 연구" 한국화재소방학회 26 (26): 48-54, 2012

      2 "http://www.nema.go.kr"

      3 "http://www.moleg.go.kr/main.html"

      4 "http://www.fire.nist.gov/fire/fires/kiosk/kisk.html"

      5 National Emergency Management Agency, "The report on the model for the prevention and reduction of spread of extensive demage in high-rise & complex building areas" 2010

      6 National Emergency Management Agency, "Next Generation Fire Protection & Safety Core Technology Development Program(Performance evaluation and DB construction on medium-scale vertical fire)" 313-423, 2010

      7 "National Fire Safety Codes of Smoke Control System"

      8 S. U. Kim, "Building smoke control system" 22 (22): 78-91, 2005

      9 J.S. Kim, "A Study on the Design method of Presurization System for Smoke Control" The Graduate School of Kyonggi University 2001

      10 Y. J. Bae, "A Study on Preventing Spread of Smoke and Securing Safety of Evacuation in Central Core Type High-Rise Buildings" The Graduate School of Gachon University 2012

      1 민세홍, "외장재에 의한 동시다발적인 화재의 피난위험성에 관한 연구" 한국화재소방학회 26 (26): 48-54, 2012

      2 "http://www.nema.go.kr"

      3 "http://www.moleg.go.kr/main.html"

      4 "http://www.fire.nist.gov/fire/fires/kiosk/kisk.html"

      5 National Emergency Management Agency, "The report on the model for the prevention and reduction of spread of extensive demage in high-rise & complex building areas" 2010

      6 National Emergency Management Agency, "Next Generation Fire Protection & Safety Core Technology Development Program(Performance evaluation and DB construction on medium-scale vertical fire)" 313-423, 2010

      7 "National Fire Safety Codes of Smoke Control System"

      8 S. U. Kim, "Building smoke control system" 22 (22): 78-91, 2005

      9 J.S. Kim, "A Study on the Design method of Presurization System for Smoke Control" The Graduate School of Kyonggi University 2001

      10 Y. J. Bae, "A Study on Preventing Spread of Smoke and Securing Safety of Evacuation in Central Core Type High-Rise Buildings" The Graduate School of Gachon University 2012

      11 Y.J. Bae, "A Study Evacuation Appropriateness for the Residential Building by Simulation(FDS, Simulex)" 52 : 1-2, 2009

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2024 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2019-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2017-12-01 평가 등재후보 탈락 (계속평가)
      2016-01-01 평가 등재후보학술지 유지 (계속평가) KCI등재후보
      2015-12-01 평가 등재후보로 하락 (기타) KCI등재후보
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2005-08-29 학술지명변경 한글명 : 안전경영과학회지 -> 대한안전경영과학회지
      외국어명 : 미등록 -> Journal of Korea Safety Management & Science
      KCI등재후보
      2005-03-30 학회명변경 한글명 : 안전경영과학회 -> 대한안전경영과학회
      영문명 : Safety Management & Science -> Korea Institute of Safety Management and Science
      KCI등재후보
      2005-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.15 0.15 0.2
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.2 0.2 0.333 0.06
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼