ABSTRACT With the recent start of the redevelopment of the areas adjacent to the HanRiver,plansforandguidelinesontheheightofthelandscapehavebeenmade. Previous studies have set the building height at the same value as the building width. The build...

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=T11730083
서울 : 서울시립대학교, 2009
학위논문(석사) -- 서울시립대학교 도시과학대학원 , 도시계획학과 , 2009. 8
2009
한국어
539.7 판사항(4)
서울
Study on the Elevation Blockage Ratio of the Area Adjacent to the Han River according to the Angle of Elevation:
vi, 93, [4] p. : 삽도 ; 26 cm.
지도교수:김기호
참고문헌 : p.92-93
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
ABSTRACT With the recent start of the redevelopment of the areas adjacent to the HanRiver,plansforandguidelinesontheheightofthelandscapehavebeenmade. Previous studies have set the building height at the same value as the building width. The build...
ABSTRACT
With the recent start of the redevelopment of the areas adjacent to the HanRiver,plansforandguidelinesontheheightofthelandscapehavebeenmade.
Previous studies have set the building height at the same value as the building width. The building height can be changed, however, due to the elevation angle, which is visually perceived from the landscape control point. In other words, such previous studies did not consider the feeling of being threatened that can be caused by the resulting visual blockage ratio.
The EBR formula that is being used to control the landscape of the HanRiverisasfollows:
EBR = The total projection area at the visual axial direction (A) / the maximum length of the complex (L).
The conventional EBR can be controlled at a certain height and width. It has limits, however, in controlling the height of ultra-high-rise buildings in the area adjacent to the HanRiver.
In this study, the feeling of being threatened due to the change in height was examined by applying the elevation angle. To do this, the elevation blockage ratio was analyzed by multiplying the projection area by the visual axial direction, which is the same as the threshold value of the elevation angle, and by the preset weight value, and by dividing the product by the maximum length from the landscape control point. In addition, the height value of each AE from the standard landscape control point was calculated and divided by the blue under 14°, the green under 18°, the yellow under 27°, the orange under 45°, and the red over 45° for the analysis. (The analysis window is similar to the rainbow, so it is called the “rainbow window analysis.”)
Using the D/H ratio of the AE, the EBR formula, in which the elevation angle was applied, was formulated as follows:
EBR to which the elevation angle was applied = Σ {The total projection area at the height of the elevation angle with the visual axial direction (A) x the weight}/ The maximum length of the complex (L).
A block of the Banpo Apartment Complex was selected for the analysis. The change in the EBR before and after the development and in the EBR to which the feeling of being threatened was applied were analyzed from nine viewpoints after modeling an average 30-story building from the existing average 12-story buildings.
The results showed that the height change due to the redevelopment had no influence on the distant-range view and the middle-range view. On the short-range view, however, the rate of increase/decrease in the EBR was 258.55% and the rate of increase/decrease in the EBR to which the feeling of being threatened was applied was 348.76%.
These results could not have been due to the simple change in the height from 12 floors to 30 floors.
Even though the EBR increased by 2.5 times in the short-range view, the actual feeling of being threatened by the blockage increased 3.5 times. In short, it can be said that the feeling of being threatened according to the increase in the building height increased by double the EBR.
If the AE is applied to the conventional EBR that is used to control the landscape and the height of the area adjacent to the Han River, a better ‘open view’ can be provided by reducing the visual blockage ratio of the AE and the D/H ratio. This study can be used as the landscape indicator according to the EBR to solve problems related to the feeling of being threatened, which can occur when viewing the HanRiver from different viewpoints.
*EBR = Elevation blockage ratio
**AE = Angle of elevation
KEYWORDS
Han River, Angle of elevation, Elevation blockage ratio, Viewpoint.
국문초록 최근 한강연접지역의 재개발 시점이 도래하면서 경관을 위한 높이에 관한 계획과 지침들이 마련되었다. 선행연구에서는 건물높이를 건물 폭과 같은 개념으로 설정하였다. 조망...
국문초록
최근 한강연접지역의 재개발 시점이 도래하면서 경관을 위한 높이에 관한 계획과 지침들이 마련되었다.
선행연구에서는 건물높이를 건물 폭과 같은 개념으로 설정하였다. 조망점에서 시지각(視知覺)되는 앙각(仰角)에 의한 건물높이의 변화가 생긴다. 이로 인한 시각적 차폐에 따른 위압감을 고려하지 않고 있다.
한강의 경관규제를 위해 기존에 사용되어진 입면차폐도의 공식은 다음과 같다.
○입면차폐도 = 조망축방향 투영입면적 합계(A ) / 단지 최장길이(L )
하지만, 기존에 사용되어졌던 입면차폐도의 경우 높이와 폭에 대해 어느 정도 규제가 가능하지만, 한강연접지역의 초고층화에 대한 높이규제에는 기능의 한계가 있다.
본 연구에서는 仰角을 적용하여 높이변화에 따른 실제적인 위압감을 적용하였다. 仰角의 한계값에 해당하는 조망축방향 투영입면적과 미리설정한 경중률값을 곱하고, 그 합에 조망축에서 본 단지 최장길이를 나누어 입면차폐도를 분석하였다. 앙각의 D/H비를 이용하여 기준조망점에서의 각 앙각에 대한 높이값을 구하여 입면차폐면적에 14°이하에 파랑(BLUE), 18°이하에 초록(GREEN), 27°이하에 노랑(YELLOW), 45°이하에 주황(ORANGE), 45°초과에 빨강(RED)로 나누어 분석하였다. (분석창이 무지개와 유사하여 RAINBOW WINDOW ANALYSIS라 명명하였다.)
仰角을 적용한 입면차폐도 공식은 다음과 같다.
○仰角을 적용한 입면차폐도 = Σ{조망축방향 앙각높이부분 투영입면적(A ) X 경중률}/ 단지 최장길이(L )
반포아파트지구의 한블럭을 분석대상지로 설정하였다.
기존 평균층수12층에서 평균층수 30층(최고층수50층)규모로 모델링하여 9개의 조망점에서 각각 개발전· 후에 따른 입면차폐율 변화와 위압감을 적용한 입면차폐율을 분석하였다.
그 결과 개발에 따른 높이변화로 중경과 원경에서는 크게 영향을 받지 않았지만, 근경에서는 입면차폐 증감율은 254.30%로 나타났고, 위압감을 적용한 입면차폐증 감율은 348.76%로 나타났다.
이것은 단순히 높이가 12층에서 30층으로 바뀌었다 의 문제가 아니다.
근경에서의 입면차폐도는 2.5배가 되었지만, 사람이 느끼는 차폐에 대한 위압감은 3.5배로 늘었다고 할 수 있다.
다시 정리하면, 높이 증가에 따라 사람이 느끼는 위압감은 입면차폐도에 비해 배로 증가했음을 알 수 있다.
기존의 입면차폐도에 의해 규제되었던 한강연접지역경관에 仰角을 적용할 경우 D/H비를 낮추고 높은 앙각부분에 대한 시각적 차폐도를 줄여 개방감을 높일 수 있다. 한강의 경관을 다각도의 조망점에서 인지할 경우 발생하는 위압감을 해소할 수 있는 입면차폐에 따른 경관지표로 활용되기를 바란다.