RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      Maxillary Sinus의 inferior wall의 피질골 두께가 임플란트의 초기안정성에 미치는 영향에 대한 in vitro 연구 = Primary Stabillity Analysis of Dental Implants According to Cortical Bone Thickness of Maxillary Sinus Inferior Wall In Vitro

      한글로보기

      https://www.riss.kr/link?id=A106535266

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      rimary stability of dental implant is a very important factor of dental implant success. However, few data are available for comparing the primary stability characteristics of less 10mm cancellous and cortical bone thickness. The purpose of this study...

      rimary stability of dental implant is a very important factor of dental implant success. However, few data are available
      for comparing the primary stability characteristics of less 10mm cancellous and cortical bone thickness. The purpose of this
      study were to measure the primary implant stability according to sinus inferior wall's cortical bone thickness. Swine bones
      which have 6,8 and 10 mm bone height and 1 mm and 1.5 mm cortical bone thickness were selected as an experimental
      model. As treated specimens one side cortical bone was removed. The assemblies were divided into groups of each 30
      swine bone specimens according to implant diameter (4.3D group: 4.3mm, 4.8D group: 4.8mm),total bone height (6H group:
      6.0mm, 8H group: 8.0mm, 10H group: 10.0mm),and cortical bone thickness (1C: 1.0 mm, 1.5C: 1.5 mm). Implant stability
      as a function of resonance frequency analysis, peak insertion torque were recorded for each fixture site after placement
      and removal. The RFA values of 1.5C group was significantly higher than that of 1C group (p < 0.05). The peak insertion
      torque of 1.5C group was significantly higher than that of 1C group (p < 0.05). Within the limits of this study, thickness
      of cortical bone have some influences on the primary stability of implants.

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2024 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2019-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼