RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      AC-PDP의 유지방전 전극사이의 간격과 어드레스 방전 특성과의 상관성 분석 = The Analysis of the Correlation between the Sustain-Electrode Gap of an AC-PDP and Address Discharge Characteristics

      한글로보기

      https://www.riss.kr/link?id=A76533637

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      To drive the high-image quality plasma displays of XGA and/or full-HD, we must effectively improve the driving waveform, which get the reset period for the stabilized control of wall charges, the address period to select discharge or non-discharge, an...

      To drive the high-image quality plasma displays of XGA and/or full-HD, we must effectively improve the driving waveform, which get the reset period for the stabilized control of wall charges, the address period to select discharge or non-discharge, and sustain period for luminance in 1 Tv-frame, and also the display quality. To accomplish them. the development of the technology for the fast address discharge is required. In this paper. the correlation between the sustain-electrode gap and the address discharge characteristics for the high-speed addressing was analyzed using the measurements of dynamic voltage margins. Results showed that the narrower the gap between the sustain electrodes, the narrower the width of the scan pulse became and a dynamic margin of data voltage of 29.2 V was obtained at scan pulse width of 1.0 ㎲ and V<SUB>ramp</SUB> of 240 V for driving 4-inch test penal. which the gap between sustain electrodes was 65 um.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 패널의 구동 및 방전 특성 분석 방법
      • 3. 실험 및 고찰
      • 4. 결론
      • Abstract
      • 1. 서론
      • 2. 패널의 구동 및 방전 특성 분석 방법
      • 3. 실험 및 고찰
      • 4. 결론
      • 참고문헌
      • 저자소개
      더보기

      참고문헌 (Reference)

      1 S. T. de Zwart, "Wall voltage fingerprint method in a three-electrode PDP Cell" Proc. of IDW01 845-848, 2001.12.

      2 Y. D. Kim, "The relation between opposed firing and ramp reset voltage in AC-PDP driving waveform" Proc. of IDW02 717-720, 2002.12

      3 M. Kasahara,, "New drive system for PDPs with improved image quality: plasma AI" 158-161, 1999.5

      4 Yongduk Kim, "Analysis of the influence of the address electrode width on high-speed addressing using the Vt close curve and dynamic Vdata margin" KIEE International Transactions on EA 5-c (5-c): 183-190, 2005.10.

      5 S. K. Lee, "Analysis of priming effect using Vt close curve" Proc. of IDW02 709-712, 2002.12

      6 Yongduk Kim, "Analysis of influence of address electrode width on address discharge characteristics using threshold voltage closed curve" 44 (44): 6752-6758, 2005.9.

      7 K. Sakita, "Analysis of cell operation at address period using wall voltage transfer function in three-electrode surface-discharge AC-PDPs" Proc. of IDW01 841-844, 2001.12.

      1 S. T. de Zwart, "Wall voltage fingerprint method in a three-electrode PDP Cell" Proc. of IDW01 845-848, 2001.12.

      2 Y. D. Kim, "The relation between opposed firing and ramp reset voltage in AC-PDP driving waveform" Proc. of IDW02 717-720, 2002.12

      3 M. Kasahara,, "New drive system for PDPs with improved image quality: plasma AI" 158-161, 1999.5

      4 Yongduk Kim, "Analysis of the influence of the address electrode width on high-speed addressing using the Vt close curve and dynamic Vdata margin" KIEE International Transactions on EA 5-c (5-c): 183-190, 2005.10.

      5 S. K. Lee, "Analysis of priming effect using Vt close curve" Proc. of IDW02 709-712, 2002.12

      6 Yongduk Kim, "Analysis of influence of address electrode width on address discharge characteristics using threshold voltage closed curve" 44 (44): 6752-6758, 2005.9.

      7 K. Sakita, "Analysis of cell operation at address period using wall voltage transfer function in three-electrode surface-discharge AC-PDPs" Proc. of IDW01 841-844, 2001.12.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2007-01-01 평가 학술지 통합(등재유지)
      2006-01-01 평가 등재학술지 유지(등재유지) KCI등재
      2004-01-01 평가 등재학술지 유지(등재유지) KCI등재
      2001-07-01 평가 등재학술지 선정(등재후보2차) KCI등재
      1999-01-01 평가 등재후보학술지 선정(신규평가) KCI등재후보
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼