RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS KCI등재

      Characteristics of radiographic images acquired with CdTe, CCD and CMOS detectors in skull radiography

      한글로보기

      https://www.riss.kr/link?id=A107329656

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: The purpose of this study was to evaluate the image quality, diagnostic efficacy, and radiation dose associated with the use of a cadmium telluride (CdTe) detector, compared to charge-coupled device (CCD) and complementary metal oxide semicon...

      Purpose: The purpose of this study was to evaluate the image quality, diagnostic efficacy, and radiation dose associated with the use of a cadmium telluride (CdTe) detector, compared to charge-coupled device (CCD) and complementary metal oxide semiconductor(CMOS) detectors. Materials and Methods: Lateral cephalographs of a phantom (type 1) composed of synthetic polymer filled with water and another phantom (type 2) composed of human skull macerated with polymer coating were obtained with CdTe, CCD, and CMOS detectors. Dosimeters placed on the type 2 phantom were used to measure radiation. Noise levels from each image were also measured. McNamara cephalometric analysis was conducted, the dentoskeletal configurations were assessed, and a subjective evaluation of image quality was conducted. Parametric data were compared via 1-way analysis of variance with the Tukey post-hoc test, with a significance level of 5%. Subjective image quality and dentoskeletal configuration were described qualitatively. Results: A statistically significant difference was found among the images obtained with the 3 detectors(P<0.05), with the lowest noise level observed among the images obtained with the CdTe detector and a higher subjective preference demonstrated for those images. For the cephalometric analyses, no significant difference (P>0.05) was observed, and perfect agreement was seen with regard to the classifications obtained from the images acquired using the 3 detectors. The radiation dose associated with the CMOS detector was higher than the doses associated with the CCD (P<0.05) and CdTe detectors(P<0.05). Conclusion: Considering the evaluated parameters, the CdTe detector is recommended for use in clinical practice.

      더보기

      참고문헌 (Reference)

      1 Takahashi T, "Recent progress in CdTe and CdZnTe detectors" 48 : 950-959, 2001

      2 van der Stelt PF, "Principles of digital imaging" 44 : 237-248, 2000

      3 Shvydka D, "Performance of large area thinfilm CdTe detector in diagnostic X-Ray imaging" 2 : 98-109, 2013

      4 Sanderink GC, "Intraoral detectors. CCD, CMOS, TFT, and other devices" 44 : 249-255, 2000

      5 Katsumata A, "Initial evaluation of linear and spatially oriented planar images from a new dental panoramic system based on tomosynthesis" 112 : 375-382, 2011

      6 Parks ET, "Digital radiography : an overview" 3 : 23-39, 2002

      7 Ogawa K, "Development of a new dental panoramic system based on a tomosynthesis method" 39 : 47-53, 2010

      8 Shi XQ, "Comparison of psychophysical properties of two intraoral digital sensors on low-contrast perceptibility" 42 : 20130249-, 2013

      9 Kitagawa H, "Comparison of complementary metal oxide semiconductor and charge-coupled device intraoral X-ray detectors using subjective image quality" 32 : 408-411, 2003

      10 Gilmore J, "CMOS technology for digital dental imaging"

      1 Takahashi T, "Recent progress in CdTe and CdZnTe detectors" 48 : 950-959, 2001

      2 van der Stelt PF, "Principles of digital imaging" 44 : 237-248, 2000

      3 Shvydka D, "Performance of large area thinfilm CdTe detector in diagnostic X-Ray imaging" 2 : 98-109, 2013

      4 Sanderink GC, "Intraoral detectors. CCD, CMOS, TFT, and other devices" 44 : 249-255, 2000

      5 Katsumata A, "Initial evaluation of linear and spatially oriented planar images from a new dental panoramic system based on tomosynthesis" 112 : 375-382, 2011

      6 Parks ET, "Digital radiography : an overview" 3 : 23-39, 2002

      7 Ogawa K, "Development of a new dental panoramic system based on a tomosynthesis method" 39 : 47-53, 2010

      8 Shi XQ, "Comparison of psychophysical properties of two intraoral digital sensors on low-contrast perceptibility" 42 : 20130249-, 2013

      9 Kitagawa H, "Comparison of complementary metal oxide semiconductor and charge-coupled device intraoral X-ray detectors using subjective image quality" 32 : 408-411, 2003

      10 Gilmore J, "CMOS technology for digital dental imaging"

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2019-03-27 학회명변경 한글명 : 대한구강악안면방사선학회 -> 대한영상치의학회 KCI등재
      2012-04-16 학술지명변경 한글명 : 대한구강악안면방사선학회지 -> Imaging Science in Dentistry KCI등재
      2011-03-29 학술지명변경 외국어명 : Korean Journal of Oral and Maxillofacial Radiology -> Imaging Science in Dentistry KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.12 0.12 0.11
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.11 0.12 0.217 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼