RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      카테터의 삽입으로 인한 변형을 제거한 상태의 3D 혈관 내 · 외벽 모델 생성 = Reconstruction of 3D Intima and Adventitia Model removed Deformation caused by a Catheter Insertion

      한글로보기

      https://www.riss.kr/link?id=A100970792

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      For FSI(fluid-structure interaction) analysis, many researcher reconstruct a 3D blood vessel model including intima and adventitia. For this, many researchers have registered several kinds of medical images and IVUS(intravascular ultrasound) image is used to obtain detailed cross sections of blood vessel. However, when IVUS image is taken, a catheter is inserted for put an ultrasound into the blood vessel. Because of catheter insertion, a blood vessel significantly deformed and IVUS image shows the deformed cross section of blood vessel. Therefore, a blood vessel model using IVUS image directly is in deformed state caused by catheter insertion. In this paper, we proposed a reconstruction method for a blood vessel model including undeformed intima and adventitia caused by catheter insertion.
      번역하기

      For FSI(fluid-structure interaction) analysis, many researcher reconstruct a 3D blood vessel model including intima and adventitia. For this, many researchers have registered several kinds of medical images and IVUS(intravascular ultrasound) image is ...

      For FSI(fluid-structure interaction) analysis, many researcher reconstruct a 3D blood vessel model including intima and adventitia. For this, many researchers have registered several kinds of medical images and IVUS(intravascular ultrasound) image is used to obtain detailed cross sections of blood vessel. However, when IVUS image is taken, a catheter is inserted for put an ultrasound into the blood vessel. Because of catheter insertion, a blood vessel significantly deformed and IVUS image shows the deformed cross section of blood vessel. Therefore, a blood vessel model using IVUS image directly is in deformed state caused by catheter insertion. In this paper, we proposed a reconstruction method for a blood vessel model including undeformed intima and adventitia caused by catheter insertion.

      더보기

      목차 (Table of Contents)

      • ABSTRACT
      • 1. 서론
      • 2. 변형된 상태와 변형되지 않은 상태의 혈관 모델 생성
      • 3. 변형되지 않은 상태의 혈관 모델 생성
      • 3. 결론
      • ABSTRACT
      • 1. 서론
      • 2. 변형된 상태와 변형되지 않은 상태의 혈관 모델 생성
      • 3. 변형되지 않은 상태의 혈관 모델 생성
      • 3. 결론
      • 참고문헌
      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼