RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE SCOPUS

      Compensation on Impedance of the Stratum Corneum

      한글로보기

      https://www.riss.kr/link?id=A76605446

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This study aims at compensation of the skin moisture level using skin impedance and SR factor. SR factor is related with the current diffusion into the skin layer. To efficiently analyze the current diffusion on the skin model, we used an electromagne...

      This study aims at compensation of the skin moisture level using skin impedance and SR factor. SR factor is related with the current diffusion into the skin layer. To efficiently analyze the current diffusion on the skin model, we used an electromagnetic simulation program called Ansys 10.0 Emag. We confirmed that the measured value decreases as the electric current gets more diffused to the layer below the horny layer. In order to conduct actual experiments based on the simulated result, we manufactured special electrodes with 24 pins by arranging 0.8㎜-diameter electrodes every 0.5㎜, in a 3 × 8 array. By simultaneously achieving both impedance value and SR value of skin with the manufactured electrodes, we compared the skin moisture level using the existing equipment to the skin moisture level applied using the skin impedance as well as the SR factor developed in this study. The correlation coefficient between the skin moisture level achieved from the existing equipment and the reference value was 0.615 (p<0.01), whereas the correlation coefficient between the skin moisture achieved from the regression equation in this study was 0.677 (p<0.01). Accordingly, it was confirmed that applying SR factor additionally improves the moisture level more precisely.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. Introduction
      • 2. Ansys Simulation
      • 3. Animal Testing
      • 4. Discussion
      • Abstract
      • 1. Introduction
      • 2. Ansys Simulation
      • 3. Animal Testing
      • 4. Discussion
      • 5. Conclusions
      • Acknowledgements
      • Reference
      더보기

      참고문헌 (Reference)

      1 J. Sato, "Water content and thickness of the stratum corneum contribute to skin surface morphology" 412-417, 2000

      2 R. Ivanic, "Thin film non-symmetric micro-electrode array for impedance monitoring of human skin" 332-336, 2003

      3 C. S. Yoo, "The effects of moisturizing and oiling bath for the inpatients with dry skin" 12 (12): 220-235, 1998

      4 H. Lee, "Skin science" 1st Edition, Gunja Press 2003

      5 O. G. Martinsen, "Measuring depth depends on frequency in electrical skin impedance measurements" 5 : 179-181, 1999

      6 S. Pearson, "Electrical skin impedance at acupuncture points" 13 (13): 409-418, 2007

      7 T. Yamamoto, "Electrical properties of the epidermal stratum corneum" 151-158, 1976

      8 O. G. Martinsen, "Electrical methods for skin moisture assessment" 8 : 237-245, 1995

      9 F. Norman, "Electrical conductivity measurements using microfabricated interdigitated electrodes" 1199-1202, 1993

      10 D. Fouchard, "Effect of iontophoretic current flow on hairless rat skin in vivo" 46 : 89-94, 1997

      1 J. Sato, "Water content and thickness of the stratum corneum contribute to skin surface morphology" 412-417, 2000

      2 R. Ivanic, "Thin film non-symmetric micro-electrode array for impedance monitoring of human skin" 332-336, 2003

      3 C. S. Yoo, "The effects of moisturizing and oiling bath for the inpatients with dry skin" 12 (12): 220-235, 1998

      4 H. Lee, "Skin science" 1st Edition, Gunja Press 2003

      5 O. G. Martinsen, "Measuring depth depends on frequency in electrical skin impedance measurements" 5 : 179-181, 1999

      6 S. Pearson, "Electrical skin impedance at acupuncture points" 13 (13): 409-418, 2007

      7 T. Yamamoto, "Electrical properties of the epidermal stratum corneum" 151-158, 1976

      8 O. G. Martinsen, "Electrical methods for skin moisture assessment" 8 : 237-245, 1995

      9 F. Norman, "Electrical conductivity measurements using microfabricated interdigitated electrodes" 1199-1202, 1993

      10 D. Fouchard, "Effect of iontophoretic current flow on hairless rat skin in vivo" 46 : 89-94, 1997

      11 J. Sato, "Dry condition affects desquamation of stratum corneum in vivo" 18 : 163-169, 1998

      12 Y.-A. Woo, "Development of a method for the determination of human skin moisture using a portable near-infrared system" 73 : 4964-4971, 2001

      13 P. Elsner, "Bioengineering of the Skin" 1994

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      학술지등록 한글명 : Journal of Electrical Engineering & Technology(JEET)
      외국어명 : Journal of Electrical Engineering & Technology
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 학술지 통합 (기타) KCI등재
      2006-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.45 0.21 0.39
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.37 0.34 0.372 0.04
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼