      해수담수화 시설의 시스템 구성에 따른 CaCO3 스케일 형성능 진단 = Evaluation of calcium carbonate scale formation on system design of seawater reverse osmosis plants

      한글로보기

      https://www.riss.kr/link?id=A104791909

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Fouling by inorganic scales needs to be prevented to effectively operate sea water reverse osmosis(SWRO) membrane systems. The extents of inorganic scaling with different array designs including one-pass, two-pass and several hybrid designs were evalu...

      Fouling by inorganic scales needs to be prevented to effectively operate sea water reverse osmosis(SWRO) membrane systems. The extents of inorganic scaling with different array designs including one-pass, two-pass and several hybrid designs were evaluated using seawater from southern sea near the city of Chang-Won. The used methods for evaluation were Stiff and Davis Index(S&DSI) calculation and several laboratory experiments. The formation potential of inorganic scale fouling was quite great under the examined conditions, which was confirmed by the laboratory experimental results. The inorganic scale was not avoidable fouling if any anti-scaling measures were not applied. The RO showed decreased flux under the scale formation conditions. The increases in S&DSI from 1.43 to 5 made small decreases in flux, which indicated that formation of inorganic scales had more substantial effects on RO flux than amount of inorganic scales.

      더보기

      참고문헌 (Reference)

      1 김충환, "역삼투법 해수담수화" 아카데미서적 94-121, 2000

      2 "막여과 해수담수화 연구센터"

      3 Mallevialle, Joel., "Water Treatment Membrane Processes" McGraw Hill, Inc. 9 : 29-45, 1996

      4 Wolf, P.H., "UF membranes for RO desalination pretreatment" 182 : 293-300, 2005

      5 David Hasson, "Suppression of CaCO3 scale deposition by anti-scalants" 118 : 285-296, 1998

      6 Fritzmann, C., "State-of-the-art of reverse osmosis desalination" 216 : 1-76, 2007

      7 American Society of Testing Materials, "Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis" 2010

      8 Hyun-Je Oh, "Scale formation in reverse osmosis desalination: model development" 238 : 333-346, 2009

      9 Lauren F. Greenlee, "Reverse osmosis desalination: Water sources, technology, and today’'s challenges" 43 : 2317-2348, 2009

      10 Shih, W., "Ranking of antiscalant performance for gypsum scale suppression in the presence of residual aluminum" 196 : 280-292, 2006

      1 김충환, "역삼투법 해수담수화" 아카데미서적 94-121, 2000

      2 "막여과 해수담수화 연구센터"

      3 Mallevialle, Joel., "Water Treatment Membrane Processes" McGraw Hill, Inc. 9 : 29-45, 1996

      4 Wolf, P.H., "UF membranes for RO desalination pretreatment" 182 : 293-300, 2005

      5 David Hasson, "Suppression of CaCO3 scale deposition by anti-scalants" 118 : 285-296, 1998

      6 Fritzmann, C., "State-of-the-art of reverse osmosis desalination" 216 : 1-76, 2007

      7 American Society of Testing Materials, "Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis" 2010

      8 Hyun-Je Oh, "Scale formation in reverse osmosis desalination: model development" 238 : 333-346, 2009

      9 Lauren F. Greenlee, "Reverse osmosis desalination: Water sources, technology, and today’'s challenges" 43 : 2317-2348, 2009

      10 Shih, W., "Ranking of antiscalant performance for gypsum scale suppression in the presence of residual aluminum" 196 : 280-292, 2006

      11 ProDose Software, "Professional water technologies"

      12 Huiting, H., "Operation of NF/RO plants: from reactive to proactive" 139 : 183-189, 2001

      13 Schafer, A.I., "NANOFILTRATION : principles and applications" Elsevier 169-239, 2005

      14 Singh, R., "Hybrid Membrane System for Water Purification" Elsevier 84-167, 2006

      15 SCALING PREDICTION SOFTWARE, "Genesys"

      16 Miguel Angel Sanz, "Fujairah reverse osmosis plant: 2 years of operation" 203 : 91-99, 2007

      17 Hesheng Li, "Evaluation of a novel CaSO4 scale inhibitor for a reverse osmosis system" 214 : 193-199, 2007

      18 Farouq Majali, "Design and operating characteristics of pilot scale reverse osmosis plants" 222 : 441-450, 2008

      19 Tzotzi, Ch., "A study of CaCO3 scale formation and inhibition in RO and NF membrane processes" 296 : 171-184, 2007

      20 Hassan, A.M., "A new approach to membrane and thermal seawater desalination processes using nanofiltration membranes (Part 1)" 118 : 35-51, 1998

      21 Hilal, N., "A comprehensive review of nanofiltration membranes: Treatment, pretreatment, modelling, and atomic force microscopy" 170 : 281-308, 2004

      22 Schippers, Jan C., "4-Day Advanced Course on Fouling and Scaling in Reverse Osmosis"

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-12-28 학술지명변경 외국어명 : Journal of the Korean Society of Water and Wastewater -> Journal of Korean Society of Water and Wastewater KCI등재
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.2 0.2 0.21
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.19 0.15 0.342 0.01
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼