1 Dumbleton JH, "“The lysis threshold”: an erroneous and perhaps misleading concept? By Harris WH" 18 : 537-538, 2003
2 Harris WH, "Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation" 51 : 737-755, 1969
3 Røkkum M, "Tissue reactions adjacent to well-fixed hydroxyapatitecoated acetabular cups. Histopathology of ten specimens retrieved at reoperation after 0.3 to 5.8 years" 85 : 440-447, 2003
4 Tonino AJ, "The hydroxyapatite-ABG hip system:5- to 7-year results from an international multicentre study. The International ABG Study Group" 15 : 274-282, 2000
5 Rogers A, "The ABG hydroxyapatitecoated hip prosthesis : one hundred consecutive operations with average 6-year follow-up" 18 : 619-625, 2003
6 Castoldi F, "Ten-year survivorship of the Anatomique Benoist Girard I total hip arthroplasty" 22 : 363-368, 2007
7 Baker PN, "THA with the ABG I prosthesis at 15 years. Excellent survival with minimal osteolysis" 468 : 1855-1861, 2010
8 Rossi P, "Short-term results of hydroxyapatite-coated primary total hip arthroplasty" (310) : 98-102, 1995
9 Coathup MJ, "Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components" 26 : 4161-4169, 2005
10 DeLee JG, "Radiological demarcation of cemented sockets in total hip replacement" (121) : 20-32, 1976
1 Dumbleton JH, "“The lysis threshold”: an erroneous and perhaps misleading concept? By Harris WH" 18 : 537-538, 2003
2 Harris WH, "Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation" 51 : 737-755, 1969
3 Røkkum M, "Tissue reactions adjacent to well-fixed hydroxyapatitecoated acetabular cups. Histopathology of ten specimens retrieved at reoperation after 0.3 to 5.8 years" 85 : 440-447, 2003
4 Tonino AJ, "The hydroxyapatite-ABG hip system:5- to 7-year results from an international multicentre study. The International ABG Study Group" 15 : 274-282, 2000
5 Rogers A, "The ABG hydroxyapatitecoated hip prosthesis : one hundred consecutive operations with average 6-year follow-up" 18 : 619-625, 2003
6 Castoldi F, "Ten-year survivorship of the Anatomique Benoist Girard I total hip arthroplasty" 22 : 363-368, 2007
7 Baker PN, "THA with the ABG I prosthesis at 15 years. Excellent survival with minimal osteolysis" 468 : 1855-1861, 2010
8 Rossi P, "Short-term results of hydroxyapatite-coated primary total hip arthroplasty" (310) : 98-102, 1995
9 Coathup MJ, "Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components" 26 : 4161-4169, 2005
10 DeLee JG, "Radiological demarcation of cemented sockets in total hip replacement" (121) : 20-32, 1976
11 Duffy P, "Premature wear and osteolysis in an HA-coated, uncemented total hip arthroplasty" 86 : 34-38, 2004
12 Bidar R, "Longterm results of the ABG-1 hydroxyapatite coated total hip arthroplasty : analysis of 111 cases with a minimum followup of 10 years" 95 : 579-587, 2009
13 Reikerås O, "Long-term results of HA coated threaded versus HA coated hemispheric press fit cups : 287 hips followed for 11 to 16 years" 126 : 503-508, 2006
14 Stilling M, "Inferior survival of hydroxyapatite versus titanium-coated cups at 15 years" 467 : 2872-2879, 2009
15 Lazarinis S, "Increased risk of revision of acetabular cups coated with hydroxyapatite" 81 : 53-59, 2010
16 Delank KS, "Increased polyethylene wear after cementless ABG I total hip arthroplasty" 126 : 509-516, 2006
17 Tonino A, "Hydroxyapatite-coated acetabular components. Histological and histomorphometric analysis of six cups retrieved at autopsy between three and seven years after successful implantation" 83 (83): 817-825, 2001
18 Capello WN, "Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues" (355) : 200-211, 1998
19 Oosterbos CJ, "High survival rate of hydroxyapatite-coated hip prostheses : 100consecutive hips followed for 10 years" 75 : 127-133, 2004
20 Chung YY, "High revision rate of hydroxyapatite-coated ABG-I prosthesis" 14 : 543-547, 2009
21 Blacha J, "High osteolysis and revision rate with the hydroxyapatite-coated ABG hip prostheses : 65 hips in 56young patients followed for 5-9 years" 75 : 276-282, 2004
22 Røkkum M, "HA particles can be released from well-fixed HA-coated stems : histopathology of biopsies from 20 hips 2-8 years after implantation" 73 : 298-306, 2002
23 Lai KA, "Failure of hydroxyapatite-coated acetabular cups. Ten-year follow-up of 85 Landos Atoll arthroplasties" 84 : 641-646, 2002
24 Massin P, "Evaluation of cementless acetabular component migration. An experimental study" 4 : 245-251, 1989
25 Paulsen A, "Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients : findings from the Danish Hip Arthroplasty Registry" 78 : 622-628, 2007
26 Livermore J, "Effect of femoral head size on wear of the polyethylene acetabular component" 72 : 518-528, 1990
27 Brooker AF, "Ectopic ossification following total hip replacement. Incidence and a method of classification" 55 : 1629-1632, 1973
28 Cheung KW, "Early failure of smooth hydroxyapatite-coated press-fit acetabular cup--7 years of follow-up" 20 : 627-631, 2005
29 Kim SY, "Early failure of hemispheric hydroxyapatite-coated acetabular cups" 446 : 233-238, 2006
30 Geesink RG, "Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates" (225) : 147-170, 1987
31 Tonino AJ, "Bone remodeling and hydroxyapatite resorption in coated primary hip prostheses" 467 : 478-484, 2009
32 Dorr LD, "Anatomic Porous Replacement hip arthroplasty : first 100 consecutive cases" 1 : 77-86, 1990