RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      견관절 불안정성에서의 이중 조영 전산화단층촬영 소견 = Double Contrast CT Arthrographic Findings of Shoulder Instability

      한글로보기

      https://www.riss.kr/link?id=A106933527

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Cleno-humeral Joint is a ball and socket joint. It has the greatest range of movement among all the joints of the body. The greatest range of movement is inevitably accompanied by a considerable loss in stability. Thir-ty-three ...

      Cleno-humeral Joint is a ball and socket joint. It has the greatest range of movement among all the joints of the body. The greatest range of movement is inevitably accompanied by a considerable loss in stability. Thir-ty-three persons underwent Double Contrast CT arthrography of the shoulder for the evaluation of suspected shoulder derangement. We performed 62 shoulder arthrography (33 abnormal shoulders and 29 normal shoulders) and reviewed their findings retrospectively. They had recurrent shoulder dislocation (30 shoulders) or nonspecific shoulder pain (3 shoulders). Injury of the glenoid labrum was seen in 28 shoulders at double contrast CT arhrography. Among 28 eases oft he labral injury, labral detachment was seen in 15 cases, labral tear in 5 cases, and labral erosion in 8 cases. Double contrast CT arthrography also showed Hill-Sachs defect in 20 shoulders. The numbers of type 1, type 2, and type 3 capsulolabral attachment in 33 shoulder instability cases were 10, 16 and 7, respectivity, while, 16, 12 and 1 in 29 normal controls. Type 2 and 3 are more common in shoulder instability group than normal control group. Operation was done in 18 shoulders. Comparing with operation findings. the sensitivity of double contrast CT arthrography in the detection of Hill-Sachs defect was 100% with the specificity of 71% and the accuracy of 89%. The sensitivity, specificity, and accuracy of double contrast CT arthrography in the detection of labral injury were 94%, 100%, and 95% respectively. Double contrast CT arthrography is a minimally invasive and highly accurate technique for in the evaluation of glenohumeral instability.

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼