      제습제와 채널이 제습로터 성능에 미치는 영향 = Effect of Desiccant and Channel Geometrics on the Performance ofDesiccant Rotor

      한글로보기

      https://www.riss.kr/link?id=A104422840

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The desiccant rotor is the most essential component of desiccant cooling system, but one of its drawbacks to spread out is rotor size. To reduce the size of rotor the analysis of rotor performance is crucial. Systematic examination on the effect of de...

      The desiccant rotor is the most essential component of desiccant cooling system, but one of its drawbacks to spread out is rotor size. To reduce the size of rotor the analysis of rotor performance is crucial. Systematic examination on the effect of desiccant and channel geometrics has been conducted based on the numerical program previously developed. Considered parameters related to channel geometrics are channel shape and cross section area of channel, and parameters related to desiccant are mass fraction, heat capacity, density, maximum water uptake and separation factor of isotherm. Considerable reduction of rotor size is expected by adjusting the parameters.

      더보기

      참고문헌 (Reference)

      1 이대영, "제습로터 성능지표 제안" 대한설비공학회 19 (19): 537-544, 2007

      2 정재동, "재생온도가 저온인 경우 제습로터의 재생부/제습부 면적비율과 회전속도 최적화" 대한설비공학회 19 (19): 521-528, 2007

      3 Dai, Y.J., "Use of desiccant cooling to improve the performance of vapour compression air conditioning" 21 : 1185-1205, 2001

      4 Gao, Z., "Theoretical analysis of dehumidification process in a desiccant wheel" 41 : 1033-1042, 2005

      5 Halliday, S.P., "The use of solar desiccant cooling in the UK:a feasibility study" 22 : 1327-1338, 2002

      6 Henning, H.-M., "The potential of solar energy use in desiccant cycles" 24 : 220-209, 2001

      7 Liu, Y.F., "Pore structure of new composite SiO2․xH2O․yCaCl2 with uptake of water air" 46 : 551-559, 2003

      8 Dai, Y.J., "Parameter analysis to improve rotary desiccant dehumidification using a mathematical model" 40 : 400-408, 2001

      9 Zheng, W., "Numerical simulation of combined heat and mass transfer processes in a rotary dehumidifier" A23 : 211-232, 1993

      10 Aristov, Yu.I., "New composite sorbents for solar driven technology of fresh water production from atmosphere" 66 : 165-168, 1999

      1 이대영, "제습로터 성능지표 제안" 대한설비공학회 19 (19): 537-544, 2007

      2 정재동, "재생온도가 저온인 경우 제습로터의 재생부/제습부 면적비율과 회전속도 최적화" 대한설비공학회 19 (19): 521-528, 2007

      3 Dai, Y.J., "Use of desiccant cooling to improve the performance of vapour compression air conditioning" 21 : 1185-1205, 2001

      4 Gao, Z., "Theoretical analysis of dehumidification process in a desiccant wheel" 41 : 1033-1042, 2005

      5 Halliday, S.P., "The use of solar desiccant cooling in the UK:a feasibility study" 22 : 1327-1338, 2002

      6 Henning, H.-M., "The potential of solar energy use in desiccant cycles" 24 : 220-209, 2001

      7 Liu, Y.F., "Pore structure of new composite SiO2․xH2O․yCaCl2 with uptake of water air" 46 : 551-559, 2003

      8 Dai, Y.J., "Parameter analysis to improve rotary desiccant dehumidification using a mathematical model" 40 : 400-408, 2001

      9 Zheng, W., "Numerical simulation of combined heat and mass transfer processes in a rotary dehumidifier" A23 : 211-232, 1993

      10 Aristov, Yu.I., "New composite sorbents for solar driven technology of fresh water production from atmosphere" 66 : 165-168, 1999

      11 Kakac, S., "Handbook of Single-Phase Convective Heat Transfer" John Wiley & Sons, Inc 1987

      12 Jain, S., "Evaluation of solid desiccant-based evaporative cooling cycles for typical hot and humid climates" 18 : 287-296, 1995

      13 Simonson, C.J., "Energy wheel effectiveness:Part II-Correlations" 42 : 2171-2185, 1999

      14 Faust, S, "Desiccant element and manufacturing method of the same"

      15 Daou, K., "Desiccant cooling air conditioning:A review" 10 : 55-77, 2006

      16 Mazzei, P., "Desiccant HVAC systems for commercial buildings" 22 : 545-560, 2002

      17 Sphaier, L.A., "Analysis of heat and mass transfer in porous sorbents used in rotary regenerators" 47 : 3415-3430, 2004

      18 Zhang, L.Z., "A numerical study of laminar forced convection in sinusoidal ducts with arc lower boundaries under uniform wall temperature" 40 : 55-72, 2001

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2022 평가예정 계속평가 신청대상 (등재유지)
      2017-01-01 평가 우수등재학술지 선정 (계속평가)
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2001-07-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1999-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.8 0.8 0.62
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.51 0.44 0.622 0.03
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼