      Our aim in this study was to investigate the effects of course density, yarn linear density and thickness and type of conductive wire on electromagnetic shielding effectiveness. Metal/cotton conductive composite yarns were produced by the core-spun te...

      Our aim in this study was to investigate the effects of course density, yarn linear density and thickness and type of conductive wire on electromagnetic shielding effectiveness. Metal/cotton conductive composite yarns were produced by the core-spun technique on the ring spinning machine, involving stainless steel, copper and silver coated copper wires with 40 μm, 50 μm, 60 μm thicknesses and Ne10/1 and Ne20/1 count yarns. The interlock fabrics were knitted on a 7G flat knitting machine with the three different machine settings. The EMSE and the surface resistivity of knitted fabrics were measured by the co-axial transmission line method according to the ASTM-D4935-10 standard in the frequency range from 15 to 3000 MHz and by the ASTM D257-07 standard, respectively. It was observed that all fabrics shielded around 95 % of electromagnetic waves at low frequencies, 80 % at medium frequencies and 70 % at high frequencies. Increasing the course density and thickness of conductive wire in interlock knitted fabrics increased the EMSE correspondingly. The knitted fabrics that had been produced with high yarn count showed greater EMSE because there was less isolation. The effect of the metal wire type was highly significant between 15 and 600 MHz.

      더보기

      참고문헌 (Reference)

      1 H. G. Ortlek, 83 : 90-, 2012

      2 A. Bedeloglu, 104 : 1247-, 2013

      3 Z. Yildiz, 82 : 2137-, 2012

      4 M. K. Erdogan, 49 : 473-, 2012

      5 M. S. Ozen, 83 : 849-, 2013

      6 M. S. Ozen, 85 : 804-, 2014

      7 F. Ceken, 7 : 81-, 2012

      8 F. Ceken, 103 : 968-, 2012

      9 C. I. Su, 74 : 51-, 2004

      10 S. Tezel, 84 : 461-, 2013

      1 H. G. Ortlek, 83 : 90-, 2012

      2 A. Bedeloglu, 104 : 1247-, 2013

      3 Z. Yildiz, 82 : 2137-, 2012

      4 M. K. Erdogan, 49 : 473-, 2012

      5 M. S. Ozen, 83 : 849-, 2013

      6 M. S. Ozen, 85 : 804-, 2014

      7 F. Ceken, 7 : 81-, 2012

      8 F. Ceken, 103 : 968-, 2012

      9 C. I. Su, 74 : 51-, 2004

      10 S. Tezel, 84 : 461-, 2013

      11 I. C. Wrobel, 20 : 53-, 2012

      12 H. G. Ortlek, 22 : 90-, 2012

      13 H. G. Ortlek, 62 : 304-, 2011

      14 S. Palamutcu, 3 : 199-, 2010

      15 D. Soyaslan, 101 : 890-, 2010

      16 R. Perumalraj, 34 : 149-, 2009

      17 T. Muhl, 85 : 587-, 2004

      18 K. B. Cheng, 46 : 42-, 2000

      19 R. R. Bonaldi, 1-3 : 536-, 2010

      20 S. Brzezinski, 17 : 66-, 2009

      21 S. Brzezinski, 18 : 76-, 2010

      22 H. C. Chen, 184 : 124-, 2007

      23 K. B. Cheng, 25 : 699-, 2006

      24 K. B. Cheng, 34 : 971-, 2003

      25 A. Das, 34 : 144-, 2009

      26 D. Duran, 85 : 1009-, 2015

      27 K. Lai, 77 : 242-, 2007

      28 R. Perumalraj, 18 : 74-, 2010

      29 R. Perumalraj, 100 : 512-, 2009

      30 R. Perumalraj, 35 : 361-, 2010

      31 R. S. Roh, 78 : 825-, 2008

      32 T. H. Ueng, 32 : 1491-, 2001

      33 T. W. Wieckowski, 14 : 18-, 2006

      34 H. Aniolczyk, 12 : 47-, 2004

      35 T. Kim, 15 : 295-, 2006

      36 H. C. Chen, 192-193 : 549-, 2007

      37 H. C. Chen, 35 : 1249-, 2004

      38 J. Drinovsky, 9 : 109-, 2009

      39 M. S. Kim, 126 : 233-, 2002

      40 K. B. Cheng, 33 : 1219-, 2002

      41 K. B. Cheng, 13 : 378-, 2000

      42 K. B. Cheng, 31 : 1039-, 2000

      43 "Standard Test Methods for dc Resistance or Conductance of Insulating Materials, in ASTM Standard D 257-99"

      44 "Standard Test Method for Measuring the Electromagnetic Shielding Effectiveness of Planar Materials, in ASTM Standard D 4935-10"

      45 "FTTS-FA-003 Test Method of Specified Requirements of Electromagnetic Shielding Textiles"

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2013-10-01 평가 SCOPUS 등재 (등재유지) KCI등재
      2011-01-01 평가 등재후보학술지 유지 (기타) KCI등재후보
      2003-01-01 평가 SCIE 등재 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0 0 0
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0 0 0 0
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼