A power electronic inverter is developed for a high frequency induction heating application. This equipment is available for the implementation of ZVS LCL resonance method was used. Using IGBT 20MVA, 100㎑ LCL resonant induction heating equipment dur...
A power electronic inverter is developed for a high frequency induction heating application. This equipment is available for the implementation of ZVS LCL resonance method was used. Using IGBT 20MVA, 100㎑ LCL resonant induction heating equipment during the development process, 100㎑ IGBT module development process and understanding gained from the design of LCL resonant Zero Crossing through the PLL control over operation of the IGBT Soft Switching, and focused on minimizing losses. In addition, through the actual design and implementation of devices using the area to test drive the development of large inverter technology based on the test