      Sonographically Guided Core Biopsy of the Breast: Comparison of 14-Gauge Automated Gun and 11-Gauge Directional Vacuum-Assisted Biopsy Methods

      한글로보기

      https://www.riss.kr/link?id=A104530056

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Objective: To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies ofbreast lesions. Materials and Methods: We retrospectively reviewed all sonographically guidedcore biops...

      Objective: To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies ofbreast lesions.
      Materials and Methods: We retrospectively reviewed all sonographically guidedcore biopsies performed from January 2002 to February 2004. The sonographicallyguided core biopsies were performed with using a 14-gauge automatedgun on 562 breast lesions or with using an 11-gauge vacuum-assisted deviceon 417 lesions. The histologic findings were compared with the surgical, imagingand follow-up findings. The histologic underestimation rate, the repeat biopsy rateand the false negative rates were compared between the two groups.
      Results: A repeat biopsy was performed on 49 benign lesions because of thecore biopsy results of the high-risk lesions (n = 24), the imaging-histologic discordance(n = 5), and the imaging findings showing disease progression (n = 20).
      The total underestimation rates, according to the biopsy device, were 55%(12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (p = 0.226). The atypical ductal hyperplasia(ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinomaat surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma insitu (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsyand invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automatedgun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies.
      The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsiesand 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%)of the 979 core biopsies were believed to have missed the malignant lesions. Thefalse-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gunbiopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies.
      Conclusion: The outcomes of the sonographically guided core biopsies performedwith the 11-gauge vacuum-assisted device were better than those outcomesof the biopsies performed with the 14-gauge automated gun in terms ofunderestimation, rebiopsy and the false negative rate, although these differenceswere not statistically significant.

      더보기

      참고문헌 (Reference)

      1 "large-coreneedle biopsy of nonpalpable breast lesions false-negative andhistologic underestimation rates after long-term follow-up" 210 : 799-805, 1999

      2 "Underestimation of breast cancer with 11-gauge vacuumsuction biopsy" 175 : 1047-1050, 2000

      3 "Ultrasound-guided core breast biopsy:use and cost-effectiveness" 208 : 717-723, 1998

      4 "US-guided core-needle biopsy of the breast:howmany specimens are necessary" 226 : 779-782, 2003

      5 "US-guided automated large-core breast biopsy" 187 : 507-511, 1993

      6 "US ofmammographically detected clustered microcalcifications" 217 : 849-854, 2000

      7 "To excise or to sample the mammographic target:what is the goal of stereotactic 11-gauge vacuum-assisted breastbiopsy" 179 : 679-683, 2002

      8 "The utility of ultrasonographicallyguided large-core needle biopsy:results from 500 consecutivebreast biopsies" 20 : 43-49, 2001

      9 "Stereotactic core-needle biopsy of non-mass calcifications:outcome and accuracy at long-term follow-up" 4 : 217-223, 2003

      10 "Stereotactic breast biopsy of nonpalpablelesions:determinants of ductal carcinoma in situ underestimationrates" 218 : 497-502, 2001

      1 "large-coreneedle biopsy of nonpalpable breast lesions false-negative andhistologic underestimation rates after long-term follow-up" 210 : 799-805, 1999

      2 "Underestimation of breast cancer with 11-gauge vacuumsuction biopsy" 175 : 1047-1050, 2000

      3 "Ultrasound-guided core breast biopsy:use and cost-effectiveness" 208 : 717-723, 1998

      4 "US-guided core-needle biopsy of the breast:howmany specimens are necessary" 226 : 779-782, 2003

      5 "US-guided automated large-core breast biopsy" 187 : 507-511, 1993

      6 "US ofmammographically detected clustered microcalcifications" 217 : 849-854, 2000

      7 "To excise or to sample the mammographic target:what is the goal of stereotactic 11-gauge vacuum-assisted breastbiopsy" 179 : 679-683, 2002

      8 "The utility of ultrasonographicallyguided large-core needle biopsy:results from 500 consecutivebreast biopsies" 20 : 43-49, 2001

      9 "Stereotactic core-needle biopsy of non-mass calcifications:outcome and accuracy at long-term follow-up" 4 : 217-223, 2003

      10 "Stereotactic breast biopsy of nonpalpablelesions:determinants of ductal carcinoma in situ underestimationrates" 218 : 497-502, 2001

      11 "Stereotactic breast biopsy of atypical ductalhyperplasia and ductal carcinoma in situ lesions improvedaccuracy with directional" 202 : 843-847, 1997

      12 "Stereotactic and sonographic large-core biopsyof nonpalpable breast lesions:results of the RadiologicDiagnostic Oncology Group V study" 11 : 293-308, 2004

      13 "Sonographically guided directional vacuumassistedbreast biopsy using a handheld device" 177 : 405-408, 2001

      14 "Sonographic detection andsonographically guided biopsy of breast microcalcifications" 180 : 941-948, 2003

      15 "Percutaneous large-core breast biopsy:amulti-institutional study" 193 : 359-364, 1994

      16 "Papillary lesions of the breast:evaluation with stereotactic directional vacuum-assisted biopsy" 221 : 650-655, 2001

      17 "Introduction to breast ultrasound" LippincottWilliams & Wilkins 1-15, 2004

      18 "Initial success and frequency ofrebiopsy after ultrasound-guided 14-g core breast biopsy[abstract]" 180 : 10-, 2003

      19 "Imaging-histologic discordance atpercutaneous breast biopsy" 89 : 2538-2546, 2000

      20 "Image-guided breast biopsy and management of high-risk lesions" 42 : 935-946, 2004

      21 "Evaluation of 14 and 11 gauge directional,vacuum-assistedbiopsy probes and 14G biopsy guns in a breast parenchymalmodel" 205 : 203-208, 1997

      22 "Comparison of rebiopsy rates after stereotactic core needlebiopsy of the breast with 11-gauge vacuum suction probe versus14-gauge needle and automatic gun" 172 : 683-687, 1999

      23 "Comparison of automatedversus vacuum-assisted biopsy methods for sonographicallyguided core biopsy of the breast" 180 : 347-351, 2003

      24 "Calcification retrieval at stereotactic, 11-gauge,directional, vacuum-assisted breast biopsy" 208 : 251-260, 1998

      25 "Atypical ductal hyperplasia diagnosedat stereotactic breast biopsy:improved reliability with 14-gauge,directional,vacuum-assisted biopsy" 204 : 485-488, 1997

      26 "Atypical ductal hyperplasia and ductalcarcinoma in situ as revealed by large-core needle breast biopsy:results of surgical excision" 175 : 1341-1346, 2000

      27 "Analysis of cancers not diagnosed atstereotactic core breast biopsy" 203 : 151-157, 1997

      28 "American College of Radiology AmericanCollege of Radiology" 1998

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2016-11-15 학회명변경 영문명 : The Korean Radiological Society -> The Korean Society of Radiology KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.61 0.46 1.15
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.93 0.84 0.494 0.06
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼