      A Novel Design of UPS with Useful Customer Load Management Function

      한글로보기

      https://www.riss.kr/link?id=A106064366

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Traditional Uninterruptible Power Supplies (UPS) only provide stable power to critical loads in emergency situations, while Energy Storage Systems (ESS) perform functions such as generator output stabilization, frequency control, peak shaving, and loa...

      Traditional Uninterruptible Power Supplies (UPS) only provide stable power to critical loads in emergency situations, while Energy Storage Systems (ESS) perform functions such as generator output stabilization, frequency control, peak shaving, and load leveling. As the global ESS market expands, various ESS supply policies are being implemented in a number of countries. Accordingly, research and development of a hybrid UPS-ESS system combining the advantages of UPS and ESS are underway in order to ensure critical load stability in case of emergency. For such a situation, we propose the development of a system with a customer load management function by simply adding a converter and battery pack to a widely used conventional UPS. The proposed system in this paper is more economical than a hybrid UPS-ESS system or an ESS.
      In addition, the proposed system performs peak-clipping and load-shifting according to time-based rates, and has a longer power outage time in case of emergency without needing to communicate with the existing UPS.

      더보기

      참고문헌 (Reference)

      1 Guerrero JM, "Uninterruptible power supply systems provide protection" 1 : 28-38, 2007

      2 Boutin LJ, "Uninterruptible power supplies in the textile industry" 9 (9): 127-132, 1973

      3 Vazquez Nimrod, "Two-stage uninterruptible power supply with high power factor" 55 (55): 2954-2962, 2008

      4 Karve S, "Three of kind [UPS topologies, IEC stand-ard]" 46 (46): 27-31, 2000

      5 Korea Energy Agency, "Survey on the promotion policies of ESS enlargement in major countries and suggestion of domestic introduction" Korea Energy Agency 2017

      6 Niroomand M, "Review and compare-son of control methods for uninterruptible power supplies" 18-23, 2010

      7 Eom J-K, "Research of economical dispatch algorithm for ESS with UPS function" Sungkyunkwan University 2015

      8 Jang S-K, "Power management system of ESS within On-Line UPS Function"

      9 Jain PK, "Performance of a single-stage UPS system for single-phase trapezoidal-shaped AC-voltage supplies" 13 (13): 912-923, 1998

      10 Kim Sangjin, "Operation and control strategy of a new hybrid ESS-UPS system" 33 (33): 4746-4755, 2018

      1 Guerrero JM, "Uninterruptible power supply systems provide protection" 1 : 28-38, 2007

      2 Boutin LJ, "Uninterruptible power supplies in the textile industry" 9 (9): 127-132, 1973

      3 Vazquez Nimrod, "Two-stage uninterruptible power supply with high power factor" 55 (55): 2954-2962, 2008

      4 Karve S, "Three of kind [UPS topologies, IEC stand-ard]" 46 (46): 27-31, 2000

      5 Korea Energy Agency, "Survey on the promotion policies of ESS enlargement in major countries and suggestion of domestic introduction" Korea Energy Agency 2017

      6 Niroomand M, "Review and compare-son of control methods for uninterruptible power supplies" 18-23, 2010

      7 Eom J-K, "Research of economical dispatch algorithm for ESS with UPS function" Sungkyunkwan University 2015

      8 Jang S-K, "Power management system of ESS within On-Line UPS Function"

      9 Jain PK, "Performance of a single-stage UPS system for single-phase trapezoidal-shaped AC-voltage supplies" 13 (13): 912-923, 1998

      10 Kim Sangjin, "Operation and control strategy of a new hybrid ESS-UPS system" 33 (33): 4746-4755, 2018

      11 Martinez S, "Off-line uninterruptible power supply with zero transfer time using integrated magnetics" 36 (36): 441-445, 1989

      12 Abusara M, "Line-interactive UPS for microgrids" 61 (61): 1292-1300, 2014

      13 Park Jae-Kyu, "High-performance transformerless on-line UPS" 55 (55): 2943-2953, 2008

      14 Choi Jin-Ha, "High-performance online UPS using three-leg-type converter" 52 (52): 889-897, 2005

      15 Yang J-H, "Energy storage system with PV generation and on-line UPS functions" 1-4, 2014

      16 임승범, "ESS 기능을 갖는 하이브리드 UPS" 전력전자학회 19 (19): 266-275, 2014

      17 D Dong, "Design of hybrid ac-dc-ac topology for uninterruptible power supply" 1-5, 2015

      18 Leadbetter J, "Battery storage system for residential electricity peak demand shaving" 55 : 685-692, 2012

      19 Nair CNK, "Battery energy storage systems : assessment for small-scale renewable energy integration" 42 (42): 2124-2130, 2010

      20 Racine MS, "An overview of uninterruptible power supplies" 159-164, 2005

      21 Tan X, "Advances and trends of energy storage technology in microgrid" 44 : 179-191, 2013

      22 Yeh CC, "A reconfi gurable un-interruptible power supply system for multiple power quality applications" 22 (22): 1361-1372, 2007

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      학술지등록 한글명 : Journal of Electrical Engineering & Technology(JEET)
      외국어명 : Journal of Electrical Engineering & Technology
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 학술지 통합 (기타) KCI등재
      2006-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.45 0.21 0.39