      Purpose: To investigate the relation between corneal higher-order aberrations and intraocular straylight. Methods: Fifty eyes with an ZCB00 (Abbott Medical Optics, Santa Ana, CA, USA) were prospectively evaluated. Ocular higher-order aberrations were ...

      Purpose: To investigate the relation between corneal higher-order aberrations and intraocular straylight. Methods: Fifty eyes with an ZCB00 (Abbott Medical Optics, Santa Ana, CA, USA) were prospectively evaluated. Ocular higher-order aberrations were measured for a 4-mm pupil using Pentacam?? (Oculus Inc., Dutenhofen, Germany). Best corrected visual acuity (BCVA) and Straylight were measured at preoperation, postoperative 1 month, and 2 month using C-Quant straylight meter (Oculus GmbH, Wetzlar, Germany). Results: BCVA and Straylight were significantly improved after operation (p < 0.001). There were no statistically significant differences in corneal higher-order aberration root mean square, including spherical, coma, or trefoil aberration, at two months postoperative. Spearman correlation analysis revealed that total higher-order aberration (R = 0.315, p = 0.026) and spherical aberration (R = 0.297, p = 0.036) were significantly associated with straylight, but coma aberration (R = 0.239, p = 0.095), trefoil aberration (R = -0.036, p = 0.804) were not. Conclusions: Corneal higher-order aberration of the eye and straylight that influeces visual quality have a positive correlation. And measurement of straylight using C-Quant may reflect the corneal higher-order aberrations.

      더보기

      목차 (Table of Contents)

      • 대상과 방법 결 과 고 찰 REFERENCES
      • 대상과 방법 결 과 고 찰 REFERENCES
      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼