RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기

    검색결과 좁혀 보기

    선택해제
    • 좁혀본 항목 보기순서

      • 원문유무
      • 음성지원유무
      • 원문제공처
        펼치기
      • 등재정보
        펼치기
      • 학술지명
        펼치기
      • 주제분류
        펼치기
      • 발행연도
        펼치기
      • 작성언어
        펼치기

    오늘 본 자료

    • 오늘 본 자료가 없습니다.
    더보기
    • 무료
    • 기관 내 무료
    • 유료
    • KCI등재SCOPUS

      Corrosion Behavior of Hastelloy C-276 for Carbon-anode-based Oxide Reduction Applications

      Jeon, Min Ku,Kim, Sung-Wook,Choi, Eun-Young Korean Radioactive Waste Society 2020 방사성폐기물학회지 Vol.18 No.3

      The corrosion behavior of Hastelloy C-276 was investigated to identify its applicability for carbon-anode-based oxide reduction (OR), in which Cl<sub>2</sub> and O<sub>2</sub> are simultaneously evolved at the anode. Under a 30 mL·min<sup>-1</sup> Cl<sub>2</sub> + 170 mL·min<sup>-1</sup> Ar flow, the corrosion rate was less than 1 g·m<sup>-2</sup>·h<sup>-1</sup> up to 500℃, whereas the rate increased exponentially from 500 to 700℃. The effects of the Cl<sub>2</sub>-O<sub>2</sub> composition on the corrosion rate at flow rates of 30 mL·min<sup>-1</sup> Cl<sub>2</sub>, 20 mL·min<sup>-1</sup> Cl<sub>2</sub> + 10 mL·min<sup>-1</sup> O<sub>2</sub>, and 10 mL·min<sup>-1</sup> Cl<sub>2</sub> + 20 mL·min<sup>-1</sup> O<sub>2</sub> with a constant 170 mL·min<sup>-1</sup> Ar flow rate at 600℃ was analyzed. Based on the data from an 8 h reaction, the fastest corrosion rate was observed for the 20 mL·min<sup>-1</sup> Cl<sub>2</sub> + 10 mL·min<sup>-1</sup> O<sub>2</sub> case, followed by 30 mL·min<sup>-1</sup> Cl<sub>2</sub> and 10 mL·min<sup>-1</sup> Cl<sub>2</sub> + 20 mL·min<sup>-1</sup> O<sub>2</sub>. The effects of the chlorine flow rate on the corrosion rate were negligible within the 5-30 mL·min<sup>-1</sup> range. A surface morphology analysis revealed the formation of vertical scratches in specimens that reacted under the Cl<sub>2</sub>-O<sub>2</sub> mixed gas condition.

    • 무용전공학생의 호흡순환기능 및 혈중젖산농도에 관한 비교연구

      이종희,김말애,손흥기,김민정 경희대학교 체육과학연구소 1996 體育學論文集 Vol.24 No.-

      The purpose of this study is to investigate the cardiovascular function and blood lactate in female by part of dance major in university. For this purpose a total of 32 female students, attending university K in Seoul participated in the study. The subjects were selected randomly 24 female students majored in dance in university(Korean dance: 8, Modern dance: 8, Ballet: 8), and 8 regular female students, who did not have any dance experience. The results of the study were as follows; 1.Cardiovascular function 1)In factors of rest HR showed in Control group 76.50±3.74 beats/min, Korean dance group 72.13±4.85 beats/min, Modern dance group 71.50±4.93 beats/min, Ballet dance group 68.8±4.19beats/min. Among these group there was significantly(p〈.05). 2)In factors of HRmax showed in Korean dance group 200.63土4.78 beats/min, , Ballet dance group 198.00±6.28beats/min, Modern dance group 197.63±6.65beats/min Control group 189.75±10.51beats/min. Among these group there was significantly(p〈.05). 3)In factors of VO2/kg showed in Ballet dance group 44.46±4.09㎖/min, Korean dance group 43.95±2.95㎖/min, Modern dance group 40.73±3.26㎖/min, Control group 34.33±2.28㎖/min. Among these group there was significantly(p〈.001). 4)In factors of VCO2 showed in Korean dance group 84.31ℓ/min, Modern dance group 2.60±0.44ℓ/min, Ballet dance group 2.52±0.23ℓ/min, Control group 2.23±0.34ℓ/min. Among these group there was not significantly. 5)In factors of art-out time showed in Korean dance group 931±52.92sec, Modern dance group 916.75±40.96sec, Ballet dance group 908.88±28.44sec, Control group 809.38±70.02sec. Among these group there was significantly(p〈.001). 2.Blood lactate 1)In factors of rest time blood lactate showed in Ballet dance group 1.17±0.26.mM/ℓ, Control group 1.11±0.21mM/ℓ , Korean dance group 1.09±0.28mM/ℓ , Modern dance group 1.06±0.33mM/ℓ Among these group there was not significantly. 2)In factors of all-out time blood lactate showed in Control group 9.14±0.92mM/ℓ, Ballet dance Broup 7.79±1.14mM/ℓ, Korean dance group 7.67±1.51mM/ℓ, Modern dance group 7.42±1.18mM/ℓ, Among these group there was not significantly. 3)In factors of recovery 3 minute blood lactate showed in Control group 9.52±0.94mM/ℓ, Ballet dance group 7.68±1.73mM/ℓ, Modern dance group 7,61±0.89mM/ℓ, Korean dance group 7.52±1.78mM/ℓ. Among these group there was significantly(p〈.05). 4) In factors of recovery 5 minute blood lactate showed in Control group 9.91±1.22mM/ℓ, Korean dance group 7.97±2.38mM/ℓ, Ballet dance group 7.86±1.86mM/ℓ, Modern dance group 7.51±1.10mM/ℓ, Among these group there was significantly(p〈.05). 5)In factors of recovery 10 minute Control group 8.99±0.97mM/ℓ, Ballet dance group 6.98±1.65mM/ℓ, Korean dance group 6.96±2.08mM/ℓ, Modern dance group 6.78±1.38mM/ℓ, Among these group there was significantly(p〈.05).

    • SCOPUSKCI등재SCIE

      Ultrasonic Degradation of Endocrine Disrupting Compounds in Seawater and Brackish Water

      So Young Park,Jong Sung Park,Ha Yoon Lee,Ji Yong Heo,Yeo Min Yoon,Kyung Ho Choi,Nam Guk Her 대한환경공학회 2011 Environmental Engineering Research Vol.16 No.3

      In this study, a series of experiments was conducted on the relative degradation of commonly known endocrine-disrupting compounds such as bisphenol A (BPA) and 17α-ethinyl estradiol (Ee₂) in a single-component aqueous solution using 28 and 580 kHz ultrasonic reactors. The experiments were conducted with three different types of model water: deionized water (DI), synthetic brackish water (SBW), and synthetic seawater (SSW) at pH 4, 7.5, and 11 in the presence of inert glass beads and humic acids. Significantly higher sonochemical degradation (93-97% for BPA) occurred at 580 kHz than at 28 kHz (43-61% for BPA), regardless of water type. A slightly higher degradation was observed for Ee₂ compared to that of BPA. The degradation rate of BPA and Ee₂ in DI water, SBW, and SSW after 30 min of ultrasound irradiation at 580 kHz increased slightly with the increase in pH from 4 (0.073-0.091 min-1 for BPA and 0.081-0.094 min-1 for Ee₂) to 7.5 (0.087-0.114 min-1 for BPA and 0.092?0.124 min-1 for Ee₂). In contrast, significant degradation was observed at pH 11 (0.149-0.221 min-1 for BPA and 0.147-0.228 min-1 for Ee₂). For the given frequencies of 28 and 580 kHz, the degradation rate increased in the presence of glass beads (0.1 mm and 25 g) for both BPA and Ee₂: 0.018-0.107 min-1 without beads and 0.052-0.142 min-1 with beads for BPA; 0.021-0.111 min-1 without beads and 0.054-0.136 min-1 with beads for Ee₂. A slight increase in degradation of both BPA and Ee₂ was found as the concentration of dissolved organic carbon (DOC, humic acids) increased in both SBW and SSW: 0.107-0.115 min-1 in SBW and 0.087-0.101 min-1 in SSW for BPA; 0.111-0.111 min-1 in SWB and 0.092-0.105 min-1 in SSW for Ee₂. After 30 min of sonicating the humic acid solution, DOC removal varied depending on the water type: 27% (3 mg L-1) and 7% (10 mg L-1) in SBW and 7% (3 mg L-1) and 4% (10 mg L-1) in SSW.

    • KCI등재

      가압가열 및 Microwave 처리가 생면의 품질에 미치는 영향

      박시우,김꽃봉우리,김민지,강보경,박원민,김보람,박홍민,최정수,최호덕,안동현,Bark, Si-Woo,Kim, Koth-Bong-Woo-Ri,Kim, Min-Ji,Kang, Bo-Kyeong,Pak, Won-Min,Kim, Bo-Ram,Park, Hong-Min,Choi, Jung-Su,Choi, Ho-Duk,Ahn, Dong-Hyun 한국식품영양학회 2013 韓國食品營養學會誌 Vol.26 No.4

      중력분을 이용하여 제면한 후 가압가열, microwave 및 가압가열과 microwave 병행 처리한 후, 생면 및 삶은 면의 품질에 미치는 영향에 대하여 알아보았다. 생면의 pH는 microwave 1 min 처리구에서 무처리구와 유의적인 차이를 보이지 않았으며, 수분 함량은 autoclave 50 min 처리구에서 무처리구와 유의적인 차이를 보이지 않았고, 그 외의 처리구에서는 모두 수분 함량이 감소함을 확인하였다. 면의 색도 측정 결과는 명도는 무처리구에 비해 모든 처리구에서 감소하였으며, 적색도는 microwave 1 min 처리구는 감소한 반면, 나머지 처리구는 증가하였다. 황색도는 autoclave 50 min 처리구와 autoclave 50 min/microwave 1 min 병행 처리구에서 증가한 반면, 나머지 물리적 처리구에서는 감소하였다. 삶은 면의 색도에서는 명도, 적색도, 황색도 모두에서 무처리구에 비하여 물리적 처리구에서 증가한 값을 나타내었다. 물성 측정 결과는 경도, 부착성, 응집성, 검성, 복원성에서 무처리구와 비교시 microwave 1 min 처리구는 유의적으로 감소하였으며, 그 외 처리구에서는 유의적으로 증가한 값을 나타내었다. 탄력성과 전단력은 모든 처리구에서 유의적으로 증가하였으며, 인장력은 가압가열 30 min 처리구와 무처리구가 유의적인 차이를 보이지 않았으나, 나머지 물리적 처리구에서는 유의적으로 증가하였다. 관능 평가 결과는 생면의 경우 색 항목에서 물리적 처리구들이 유의적으로 낮은 점수를 받았다. 맛, 질감, 향 항목에서는 무처리구와 물리적 처리구간 유의적 차이를 보이지 않았다. 전체적인 기호도에서는 microwave 1 min 처리구가 가장 높은 점수를 얻었으며, 가압가열(50 min)과 microwave(1 min) 병행 처리구는 무처리구와 비슷한 점수를 얻었다. 따라서 제면 후 가압가열 및 microwave 처리가 생면 및 삶은 면에 있어서 색과 질감 항목을 보완, 개선시킨다면 알러겐성이 저감화된 면을 제품화하는데 적합할 것으로 사료되어진다.

    • 전송율 향상을 위한 다단계 상호연결망

      신용태,이철희,조민수 崇實大學校 生産技術硏究所 1996 論文集 Vol.26 No.1

      This paper proposed two Multi-statge Interconnection Network(MIN) that had multiple outlet to improve throughput. These proposed MINS were made of Clos MIN, well known Non-blocking MIN. These proposed MINs were called ECFS(Expanded Clos Switch Fabric) adn TCSF(Tandem Clos Switch Fabric). ECFS was consist of expanded number of switchs for multiple oulet. TCSF was consist of serial Clos MIN for multiple outlet. Performance evaluation of these proposed MINs was calculated arrival probability of packet through the MIN. In teh result, these proposed MINs with multiple outlet had higher throughput than existed MIN with single outlet. We know the fact that as the outlet of MIN increase, throughput of MIN increase.

    • KCI등재

      태연혈(太淵穴)의 유침 시간에 따른 체온 변화 -적외선체열촬영(赤外線體熱撮影)을 중심으로-

      이봉효 ( Bong Hyo Lee ),이경민 ( Kyung Min Lee ),박지하 ( Ji Ha Park ),김민서 ( Min Seo Kim ),김산들 ( San Deul Kim ),박병규 ( Byeong Gyu Park ),양현동 ( Hyun Dong Yang ),예성호 ( Sung Ho Yea ),이호정 ( Ho Jung Lee ),최재원 ( Jae 경락경혈학회 2012 Korean Journal of Acupuncture Vol.29 No.2

      Objectives: This study was performed to find the desirable remaining time of needle in the acupuncture treatment. Methods: The 21 volunteers were given acupuncture at LU9 vertically and needles were remained for 2 min, 10 min, 15 min, 30 min, respectively. The thermographic change induced by acupuncture was measured with Digital Infrared Thermographic Image at the following acupoints: LU11, LU10, LU9, LU8, LU5, LU1, and PC7. The statistical significance of thermographi change was evaluated using paired t-test and post hoc Wilcoxon test. Results: The most significant changes after acupuncture were produced when needles were remained for 10 min or 15 min. LU11, LU5, LU1, and PC7 were the point at which all of the remaining time produced significant change commonly. At LU11, the biggest change was produced when needle was remained for 15 min, while at LU5, LU1, and PC7, the biggest change was produced when needle was remained for 30 min, and the smallest change was produced when needle was remained for 10 min at all of acupoints of LU11, LU5, LU1, and PC7. The unbalance between left side and right was decreased the most largely in 15 min group. Conclusions: The results of this study suggest that the desirable remaining time of acupuncture needle might be 15 min.

    • KCI등재

      Accuracy of cardiac output measurements during off-pump coronary artery bypass grafting: according to the vessel anastomosis sites

      Sung Yong Park,Dae Hee Kim,Han Bum Joe,Ji Young Yoo,Jin Soo Kim,Min Kang,Yong Woo Hong 대한마취통증의학회 2012 Korean Journal of Anesthesiology Vol.62 No.5

      Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB. Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB.

    • KCI등재

      Reduction of Bacillus cereus Contamination in Biofilms on Stainless Steel Surfaces by Application of Sanitizers and Commercial Detergent

      Min-Jeong Lee,하지형,Yong-Su Kim,류지훈,하상도 한국응용생명화학회 2010 Journal of Applied Biological Chemistry Vol.53 No.1

      We established the effectiveness of a washing, detergent and sanitizer treatments for reducing Bacillus cereus (B. cereus) contamination in biofilms on stainless steel surfaces. A water treatment did not affect biofilms and chlorine treatments at 200 ppm for 10 min and 300 ppm for 5 min, iodophor at 200 ppm for 10 min, and QAC at 400 ppm for 10 min were used to eliminate all B. cereus cells. B. cereus cells after detergent treatment were eliminated by chlorine at 100 ppm for 10 min, 200 ppm for 5 min, and 300 ppm for 3 min, and with iodophor at 100 ppm for 10 min and 200 ppm for 10 min, and QAC at 400 ppm for 10 min.

    • SCIEKCI등재

      Reduction of Bacillus cereus Contamination in Biofilms on Stainless Steel Surfaces by Application of Sanitizers and Commercial Detergent

      Lee, Min-Jeong,Ha, Ji-Hyoung,Kim, Yong-Su,Ryu, Jee-Hoon,Ha, Sang-Do The Korean Society for Applied Biological Chemistr 2010 Applied Biological Chemistry (Appl Biol Chem) Vol.53 No.1

      We established the effectiveness of a washing, detergent and sanitizer treatments for reducing Bacillus cereus (B. cereus) contamination in biofilms on stainless steel surfaces. A water treatment did not affect biofilms and chlorine treatments at 200 ppm for 10 min and 300 ppm for 5 min, iodophor at 200 ppm for 10 min, and QAC at 400 ppm for 10 min were used to eliminate all B. cereus cells. B. cereus cells after detergent treatment were eliminated by chlorine at 100 ppm for 10 min, 200 ppm for 5 min, and 300 ppm for 3 min, and with iodophor at 100 ppm for 10 min and 200 ppm for 10 min, and QAC at 400 ppm for 10 min.

    • SCOPUSKCI등재

      과열증기처리 반탄화 추출물의 항산화 효과 검증에 관한 연구

      오근혜(Geun Hye Oh),남정빈(Jeong Bin Nam),양승민(Seung Min Yang),정원희(Won Hee Joung),정진산(Jin San Jeong),신종민(Jong Min Shin),강석구(Seog Goo Kang) 한국펄프·종이공학회 2018 펄프.종이기술 Vol.50 No.2

      The antioxidant properties of the extracts from torrefied wood subjected to superheated steam treatment were investigated. Total polyphenolics, total flavonoids, DPPH (2,2-diphenyl-1-picrylhydrazyl) free radical scavenging activity, reducing power, and FRAP (Ferric reducing antioxidant power) were determined to evaluate antioxidant activity. The total polyphenol content was 879.67±40.41 ㎎/mL at a concentration of 25 g/mL when the extract was subjected to a temperature of 300℃ for 10 min, and 759.67±25.17 ㎎/mL at a concentration of 25 g/mL at 350℃ for 10 min. The value of at 300℃ was 15.79% higher than that obtained at 350℃. Total flavonoid content was 111.18±3.55 ㎎/mL at a concentration of 25 g/mL at 300℃ for 10 min, and 80.58±2.58 ㎎/mL at a concentration of 25 g/mL at 350℃ for 10 min. The value at 300℃ was 37.97% higher than that obtained at 350℃. For the DPPH free radical scavenging activity, the highest scavenging activity was observed at a concentration of 6 g/mL. DPPH free radical scavenging activity at a concentration of 6 g/mL at 300℃ for 10 min was 89.83±0.03%, whereas at 350℃ for 10 min at the same concentration, it was found to be 87.99±0.1%. The value at 300℃ was 2.09% higher than that obtained at 350℃. Reducing power was determined to be 3.59±0.04 at a concentration of 25 g/mL at 300℃ for 10 min, and 2.92±0.1 at a concentration of 25 g/mL at 350℃ for 10 min. The value at 300℃ was 22.94% higher than that obtained at 350℃. FRAP was 1742±37 μM at a concentration of 25 g/mL at 300℃ for 10 min, and 1106±8 μM at a at 350℃ for 10 min. At 300℃, the FRAP value was 57.50% higher than that obtained at 350℃. Based on these results, we suggest that torrefied wood treated with superheated steam can be used in various applications because of its effective antioxidant properties.

    연관 검색어 추천

    이 검색어로 많이 본 자료

    활용도 높은 자료

    해외이동버튼