Comparison of Partial Discharge Characteristics in SF<sub>6</sub> Gas Under AC and DC
Jo, Hyang-Eun,Wang, Guoming,Kim, Sun-Jae,Kil, Gyung-Suk The Korean Institute of Electrical and Electronic 2015 Transactions on Electrical and Electronic Material Vol.16 No.6
In this paper, parameters related with partial discharge (PD) were analyzed in SF<sub>6</sub> gas under AC and DC voltages. Three electrode systems (protrusion on conductor, protrusion on enclosure, and free particle) were fabricated to simulate PD defects in a gas-insulated switchgear (GIS). All electrode systems were filled with SF<sub>6</sub> gas at 0.5 MPa. PD pulses were detected using an oscilloscope and a data acquisition (DAQ) based on IEC 60270. To analyze the PD characteristics under AC and DC voltages, parameters such as discharge inception voltage (DIV), discharge extinction voltage (DEV), pulse magnitude, repetition rate, and T-F map were compared. From the experimental results, PD was revealed to have different characteristics under AC and DC, and these results may be useful for diagnosis of power facilities operated under HVDC.
Comparison of Partial Discharge Characteristics in SF6 Gas Under AC and DC
조향은,길경석,Guoming Wang,,김선재 한국전기전자재료학회 2015 Transactions on Electrical and Electronic Material Vol.16 No.6
In this paper, parameters related with partial discharge (PD) were analyzed in SF6 gas under AC and DC voltages. Three electrode systems (protrusion on conductor, protrusion on enclosure, and free particle) were fabricated to simulate PD defects in a gas-insulated switchgear (GIS). All electrode systems were filled with SF6 gas at 0.5 MPa. PD pulses were detected using an oscilloscope and a data acquisition (DAQ) based on IEC 60270. To analyze the PD characteristics under AC and DC voltages, parameters such as discharge inception voltage (DIV), discharge extinction voltage (DEV), pulse magnitude, repetition rate, and T-F map were compared. From the experimental results, PD was revealed to have different characteristics under AC and DC, and these results may be useful for diagnosis of power facilities operated under HVDC.
몰드변압기에서 용량성 프로브에 의한 부분방전 검출 기술
정광석,박대원,차현규,차상욱,길경석,Jung, Kwang-Seok,Park, Dae-Won,Cha, Hyeon-Kyu,Cha, Sang-Wook,Kil, Gyung-Suk 한국전기전자재료학회 2011 전기전자재료학회논문지 Vol.24 No.4
This paper dealt with a partial discharge (PD) detection method for insulation diagnosis in cast-resin transformers. To detect PD pulse, a planar-capacitive probe was designed and fabricated. The probe has no insulation problem and can be installed on cast-resin transformers even in operation since it does not connect with high voltage conductor. The PD measurement system consists of the capacitive probe, a coupling network of 100 [kHz] low-cutoff frequency, and an amplifier with a gain of 40 [dB] and a frequency bandwidth of 500 [Hz]~45 [MHz]. A plane-needle and a plane-plane electrode system were fabricated to simulate insulation defects in a cast-resin transformer. Sensitivity of the PD measurement system, which is evaluated by a standard calibrator was 0.35 [mV/pC] for positive and 0.45 [mV/pC] for negative, respectively. The PD detection by the capacitive probe was less sensitive than that by a coupling capacitor according to IEC 60270, but we could analyze the magnitude and the phase distribution of PD pulse.