RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        오염물질 발생원의 실내 공기질에 관한 기여율 해석

        김태연 대한건축학회 2004 대한건축학회논문집 Vol.20 No.2

        The pollutant distribution in the air was greatly influenced on the pollutant sources and the room air distribution. Indoor air quality The concentration of the room could be considered as the sum of the concentration of each source. For controlling and designing the indoor air quality efficiently, it is very important to know the contribution ratio of pollutant sources in a room. In this paper, the method for assessing the contribution of pollutant sources named CRIAQs (Contribution Ratio to Indoor Air Qualities) was developed. This method could be calculated using the CFD (Computational Fluid Dynamics) method, which analyzes the velocity, temperature, and pollution distribution accurately. Using the method, the contribution ratio of pollutant sources of the model room was analyzed. This method was found to be very useful in this study.

      • KCI등재

        CFD를 이용한 공동주택 실내공기질 예측 및 측정

        이은정,유영희,이경회 대한건축학회 2007 대한건축학회논문집 Vol.23 No.1

        Because of the high airtightness and insulation of the building, indoor environment has been largely polluted resulted from insufficient ventilation and occurrence of new air pollutant. These factors have made worse indoor air quality and caused symptoms of the SBS (Sick Building Syndrome), BRI(Building Related Illness), SHS(Sick Home Syndrome). Therefore, it is needed to evaluate and control indoor pollutants quantitatively considering influence on indoor air environment. Related to this, countermeasures for ensuring of the healthy and comfortable indoor air quality are required through indicating criteria in application materials. This study analyzed materials used in livingroom through measuring ventilation performance and TVOC, HCHO of apartment housing and evaluated IAQ by material application using CFD(Computational Fluid Dynamics), made suggestions on ways to improve the existing problems. The purpose of this study is to support decision making in building finishing materials to get optimum air environment in early stage of designing of apartment housing. .

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼