RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        금 증착 측면연마 광섬유를 이용한 1.93㎛ 모드잠금 펨토초 전광섬유 MOPA 레이저

        정민완,구준회,이주한,Jung, Minwan,Koo, Joonhoi,Lee, Ju Han 한국광학회 2014 한국광학회지 Vol.25 No.6

        We experimentally demonstrate the use of a gold-deposited side-polished fiber as a $2-{\mu}m$-band polarizing device to produce mode-locked pulses from a thulium/holmium-codoped fiber ring cavity. The mode-locking effect was induced by nonlinear transmission caused by the gold-deposited side-polished fiber, due to nonlinear polarization rotation of the oscillated beam within the fiberized cavity. It is also shown that ~558-fs pulses with a peak power of ~6.7 kW could readily be produced at a wavelength of 1935 nm through subsequent thulium/holmium-codoped fiber amplification, due to the higher-order soliton compression effect. 본 논문에서는 금이 증착된 측면연마 광섬유를 $2{\mu}m$ 대역 편광기로 이용하여 Thulium/Holmium 첨가 광섬유 기반 링 캐비티로부터 모드 잠금 레이저를 구현할 수 있음을 실험적으로 보였다. 모드 잠금 현상은 광섬유로 구성된 공진기 내부에서 진행하는 빔이 겪는 Nonlinear Polarization Rotation 현상에 기반하여 삽입된 금 증착 측면연마 광섬유에서 발생되는 Nonlinear Transmission 반응에 의해 유도되었다. 또한 공진기로부터 발생되는 출력 $1.93{\mu}m$ 파장의 광펄스를 Thulium/Holmium 첨가 광섬유 증폭기를 통과시켜 Higher Order Soliton Effect를 통해 압축시킴으로써 최대 첨두 출력 ~6.7 kW를 갖는 펄스폭 ~558 fs의 고출력 펨토초 펄스를 얻을 수 있음을 실험적으로 보였다.

      • KCI등재

        100-MeV 양성자 빔을 이용하여 169Tm(p,3n)167Yb 반응에 의해 생성된 167Yb 방사성동위원소에서 방출되는 감마선 스펙트럼 비교 연구

        이삼열 한국방사선학회 2022 한국방사선학회 논문지 Vol.16 No.7

        The measurement of branching ratio of 167Yb radioactive isotopes from gamma-ray spectrum of 169Tm(p,3n)167Yb reaction were performed by using a 100-MeV proton linear accelerator of the Korea Multi-purpose Accelerator Complex (KOMAC). The 167Yb isotope has a half-life of 17.5 minutes and decays to 169Tm. The gamma rays generated from the 167Yb isotope were measured using an HPGe detector gamma ray spectroscopy system. The energy calibration of the detector and the efficiency measurement of the detector were determined using a standard source. The gamma rays of known main energy (62.9, 106.2, 113.3, 143.5 and 176.3 keV) were measured. On the other hand, information about the intensity of the generated gamma rays is very inaccurate. Therefore, in this study, the decay strength of the main gamma rays was accurately measured. Overall, it was different from the previously known results, and in particular, it was found that the intensity of the main decay gamma ray, such as the 113.3 and 106.2 keV gamma ray, was overestimated, and it was found that the gamma ray, such as 62.9, 116.7 and 143.5 keV was underestimated. The present results are considered to be important information in the fields of nuclear fusion, astrophysics and nuclear physics in the future. 양성자과학연구단의 100-MeV 양성자선형가속기의 양성자를 사용하여 천연 169Tm과 핵반응을 일으켜 167Yb 방사성동위원소를 생성하였다. 생성된 동위원소는 17.5분의 반감기를 가지며 167Tm로 붕괴한다. 이때 발생하는 감마선을 HPGe 검출시스템을 사용하여 측정하였다. 검출기의 에너지 교정 및 검출기의 효율 측정은 표준선원을 사용하여 결정하였다. 기존에 알려진 Table of Isotopes의 주요 감마선 에너지는 모두 측정되었다. 한편, 현재까지 알려진 발생되는 감마선의 강도에 대한 정보는 매우 부정확한 상황이다. 따라서 본 연구를 통하여 주요 감마선에 대한 붕괴 강도를 정확하게 측정하였다. 전체적으로 기존에 알려져 있던 결과들과 상이한 차이를 보였으며 특히 113.3 및 106.2 keV 감마선 같은 주 붕괴 감마선의 강도들이 과대평가 되었다는 사실을 알게 되었고 62.9, 116.7 및 143.56 keV의 감마선 들은 과소평가 된 감마선들임을 알게 되었다. 본 연구의 결과는 핵융합 연구, 천체 물리학 및 핵물리 분야에 있어서 중요한 정보가 될 것으로 생각된다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼