http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Passive Bypass Using Anthron Tube in Adult Living Donor Liver Transplantation
SungGyu Lee,Shin Hwang,KiHoon Kim,ChulSoo Ahn,KwangMin Park,YoungJoo Lee,DeokBog Moon,ChongWoo Chu,HyunSeong Yang,SungHoon Cho,KiBong Oh,TaeYong Ha,KiWon Song,YunSik Yu,PyungChul Min 대한외과학회 2002 대한외과학회 학술대회 초록집 Vol.2002 No.10
강윤식(Yunsik Kang),강희용(Heeyong Kang),이교우(Gyowoo Lee),양성모(Sungmo Yang),김민수(Minsoo Kim),이성기(Sungki Lee),김쾌만(Queman Kim) 한국자동차공학회 2008 한국자동차공학회 춘 추계 학술대회 논문집 Vol.- No.-
Recently, weight reduction for an automobile component has been sought to achieve fuel efficiency and energy conservation. So many automobile components is producted by engineering plastic. Therefore this parts is important safety evaluation. In this paper, we presents effectiveness of leaking tester for safety evaluation in battery case made by injection molding. In oder to analyze the stress&displacement of this component, we need to conduct structure Finite Element Analysis. Test condition was decided using this work. And leaking tester is tested using test system, tester function was evaluation. Finally, it was conclude decision standard through results of test. Additionally, safety of impossible test condition is evaluated through FE analysis.
0.18-㎛ CMOS 공정을 이용한 6~18 ㎓ 8-비트 실시간 지연 회로 설계
이상훈(Sanghoon Lee),나윤식(Yunsik Na),이성호(Sungho Lee),이성철(Sung Chul Lee),서문교(Munkyo Seo) 한국전자파학회 2017 한국전자파학회논문지 Vol.28 No.11
본 논문에서는 6~18 ㎓ 대역 8-비트 true time delay(TTD) 회로의 설계 및 측정결과에 대하여 기술하였다. 단위 지연회로는 상대적으로 시간 지연 변화율이 일정한 m-유도 필터(m-derived filter)를 이용하였다. 설계한 8-비트 TTD는 2개의 single-pole double-throw(SPDT)와 7 개의 double-pole double-throw(DPDT) 스위치로 구현하였으며, 인덕터를 이용하여 반사특성을 개선하였다. 설계된 8-비트 TTD는 0.18 ㎛ CMOS 공정을 이용하여 제작하였다. 측정된 TTD 회로의 시간 가변 범위는 250 ㎰이고, 시간 지연 해상도는 약 1 ps이다. 6~18 ㎓의 동작 주파수에서 RMS 시간 지연 오차는 11 ps 미만이며, 입출력 반사 손실은 10 ㏈ 이상이다. 공급 전압은 1.8 V이며, 소비 전력은 0.0 ㎽이다. 칩 면적은 2.36×1.04 ㎟이다. This paper presents a 6~18 ㎓ 8-bit true time delay (TTD) circuit. The unit delay circuit is based on m-derived filter with relatively constant group delay. The designed 8-bit TTD is implemented with two single-pole double-throw (SPDT) switches and seven double- pole double-throw (DPDT) switches. The reflection characteristics are improved by using inductors. The designed 8-bit TTD was fabricated using 0.18 ㎛ CMOS. The measured delay control range was 250 ㎰ with 1 ps of delay resolution. The measured RMS group delay error was less than 11 ps at 6~18 ㎓. The measured input/output return losses are better than 10 ㏈. The chip consumes zero power at 1.8 V supply. The chip size is 2.36×1.04 ㎟.
이재흔(Jaeheun Lee),유윤식(Yunsik Yu),이재승(Jaeseung Lee),임인철(Inchul Im) 한국방사선학회 2014 한국방사선학회 논문지 Vol.8 No.6
본 연구는 임상적으로 정형화된 경추부 MR 검사에서 틀니 제거 환자들의 불수의적 구강운동, 침 삼킴 등의 불수의적 구강 운동에 의한 움직임 인공물을 개선하기 위해 구강내 삽입 유도 기구를 이용한 검사방법을 제안하고 인공물을 최소화하여 질환의 경계가 불분명했던 부분을 명확하게 하여 최적의 영상을 만들고자 하였다. 2014년 1월 1일부터 2014년 6월 31일까지 경추부 질환으로 내원한 환자 중 틀니를 착용한 30명을 대상으로 경추 자기공명검사를 시행하였다. 방법으로는 틀니를 제거한 후 바로 누운(supine position)자세로 T₁-TSE-Sagittal, T₂-TSE-Sagittal, T₁-TSE-Axial, T₂-TSE-Axial을 획득하고 환자의 입에 구강내 삽입 유도 기구를 삽입한 후 T₁-and T₂-TSE-Axial을 검사하였다. 결과로는 정량적 분석 SNR은 구강 삽입 유도 기구 사용 전 T₁-TSE-Axial이 22.33±8.59, 사용 후 25.21±7.93, T₂-TSE-Axial은 사용 전 14.49±5.74, 사용 후 16.61±6.72이었다. CNR은 T₁-TSE-Axial이 0.23±0.01, T₂-TSE-Axial이 0.21±0.01로 측정되었다. 정성적 분석으로는 T₁-TSE-Axial에서 구강내 삽입 유도기구 사용 전 3.49±0.11, 사용 후 3.95±0.14로 나타났으며 T₂-TSE-Axial에서는 구강내 삽입 유도기구 사용 전 3.25±0.18, 삽입 후 3.68±0.09로 나타났다. 결론적으로 구강내 삽입 유도 기구의 사용으로 움직임 인공물이 해소되어 영상의 대조도와 분해능이 향상되었고 영상 판독에 있어 질환의 식별능력이 우수하여 영상의 질이 향상됨을 알 수 있었다. This study aims to suggest and test methods using an orally inserted guiding device in order to improve a motion artifact by involuntary oral motor such as removing one's dentures and swallowing saliva clinically structured cervical spine scan and to make the optimal image by minimizing motion artifact. A cervical spine test was conducted with 30 patients who wore dentures among those who had a cervical spinal disease from January 1, 2014 through June 30, 2014. As for testing methods, after removing denture, T₁-TSE-Sagittal, T₂-TSE-Sagittal, T₁-TSE-Axial and T₂-TSE-Axial were obtained in a normal position and a supine position; the orally inserted guiding device was inserted in patients' mouth; and then T₁-TSE-Axial and T₂-TSE-Axial were retested. As a result, in SNR, T₁-TSE-Axial before inserting an orally inserted guiding device was 22.33±8.59; T₁-TSE-Axial after inserting the orally inserted guiding device was 25.21±7.93; T₂-TSE-Axial before inserting the orally inserted guiding device was 14.49±5.74; and T₂-TSE-Axial after inserting the orally inserted guiding device was 16.61±6.72. In CNR, T₁-TSE-Axial was measured at 0.23±0.01 while T₂-TSE-Axial at 0.21±0.01. As a result of the qualitative analysis, T₁-TSE-Axial before inserting the orally inserted guiding device was 3.49±0.11; T₁-TSE-Axial after inserting the orally inserted guiding device was 3.95±0.14; T₂-TSE-Axial before inserting the orally inserted guiding device was 3.25±0.18; and T₂-TSE-Axial after inserting the orally inserted guiding device was 3.68±0.09. As a result of using an orally inserted guiding device, the resolution and contrast of the images improved as the patients' involuntary artifact decreased because of removing dentures and swallowing saliva, and it was found that the interpretation of the images and identification of the diseases improved.
전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가
이서영(Seoyoung Lee),김경리(Kyunglee Kim),하혜경(Hyekyoung Ha),임인철(Inchul Im),이재승(Jaeseung Lee),박형후(Hyonghu Park),곽병준(Byungjoon Kwak),유윤식(Yunsik Yu) 한국방사선학회 2013 한국방사선학회 논문지 Vol.7 No.2
최근 다중검출기 CT의 보편화 된 사용으로 환자의 피폭선량이 증가하고 있다. 따라서 광자극발광선량계를 이용해 촬영 목적 부위와 주변 결정장기에 대한 환자의 피폭선량을 측정하고 그에 따른 생물학적 효과를 예측하여 저감화 방안을 제시하고자 하였다. ICRP에서 권고한 표준안을 대상으로 만들어진 인체 모형 표준 팬텀에 교정상수를 부여받은 OSD 선량계를 측정하고자 하는 좌ㆍ우 수정체, 갑상선, 촬영의 중심점, 생식선에 부착하여 각 검사 부위별 노출 조건과 동일한 상태에서 환자의 피폭 선량을 모사하였다. OSL 선량계의 평균 교정상수는 1.0058±0.0074이었으며 검사 부위별 주변 결정장기의 등가선량은 좌ㆍ우측 수정체의 경우 직접 피폭이 약 50mGy로 최대였으며 간접 피폭되는 경우 0.24mGy, 원거리에서는 0.005mGy미만의 기준 준위 이하로 측정되었다. 갑상선의 경우 두부 검사에서 10.89mGy로 최대였으며 흉부에서 7.75mGy, 복부 및 요추부, 골반부에서는 기준 미만이었다. 생식선의 경우 골반검사에서 21.98mGy로 최대였으며 간접 피폭되는 검사에서 기준 준위 미만에서 6.92mGy까지 피폭되었다. CT 검사에서 DRL에 대한 저감화 방법은 국제기구에서 권고하고 있는 방사선 방어 원칙에 대한 정당한 해석과 제도적 뒷받침이 필요하다. 따라서 환자의 피폭을 최소화하기 위해서는 정당성을 충족하여야 하며 환자의 피폭선량에 미치는 영향들을 체계화하고 조직의 불필요한 피폭을 최소화 하여야 한다. In this study measured patient exposure dose for purpose exposure area and peripheral critical organs by using optically stimulated luminescence dosimeters (OSLDs) from computed tomography (CT), based on the measurement results, we predicted the radiobiological effects, and would like to advised ways of reduction strategies. In order to experiment, OSLDs received calibration factor were attached at left and right lens, thyroid, field center, and sexual gland in human body standard phantom that is recommended in ICRP, and we simulated exposure dose of patients in same condition that equal exposure condition according to examination area. Average calibration factor of OSLDs were 1.0058 ± 0.0074. In case of left and right lens, equivalent dose was measure in 50.49 mGy in skull examination, 0.24 mGy in chest, under standard value in abdomen, lumbar spine and pelvis. In case of thyroid, equivalent dose was measured in 10.89 mGy in skull examination, 7.75 mGy in chest, 0.06 mGy in abdomen, under standard value in lumber spine and pelvis. In case of sexual gland, equivalent dose was measured in 21.98 mGy, 2.37 mGy in lumber spine, 6.29 mGy in abdomen, under standard value in skull examination. Reduction strategies about diagnosis reference level (DRL) in CT examination needed fair interpretation and institutional support recommending international organization. So, we met validity for minimize exposure of patients, systematize influence about exposure dose of patients and minimize unnecessary exposure of tissue.
초소형 비행체용 하이브리드 엔진 냉각을 위한 3D 프린팅 카울 형상 및 재질 연구
이기웅(Kiwoong Lee),김우비(Woo Bee Kim),권혁록(Hyuk Rok Gwon),김대원(Dae Won Kim),정윤식(Yunsik Jung),이현석(Hyeon Seok Lee),조성진(Sung Jin Jo),이선형(Seon Hyeong Lee) 한국추진공학회 2019 한국추진공학회 학술대회논문집 Vol.2019 No.5
본 논문에서는 하이브리드 추진시스템에 사용하는 공랭식 엔진에 3D 프린터로 제작된 카울을 적용하기 위하여 고려되어야 할 형상과 재질 특성에 대해 살펴보았다. 열/유동 해석을 통해 냉각 성능 확인 및 카울에 영향을 줄 수 있는 요소들에 대하여 연구하였으며, 실물 모사 형상의 지상 시험을 통하여 최종적으로 냉각 카울로 적용할 형상 및 재질을 선정하였다. In this paper, we studied shape and material feature which must be considered for appling 3D printing cowls for air cooling hybrid propulsion system engine. Using Heat/Flow analysis, figured the cooling efficiency and factor that can influence to cowl, then confirmed final model by ground test with actual mock-up.