http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Lee, So Jin,Huh, Myung Sook,Lee, Seung Young,Min, Solki,Lee, Seulki,Koo, Heebeom,Chu, Jun‐,Uk,Lee, Kyung Eun,Jeon, Hyesung,Choi, Yongseok,Choi, Kuiwon,Byun, Youngro,Jeong, Seo Young,Park, Kinam WILEY‐VCH Verlag 2012 Angewandte Chemie Vol.124 No.29
<P><B>Die kondensierte Fassung</B>: Thioliertes Glycolchitosan bildet durch Ladungs‐Ladungs‐Wechselwirkungen und Netzbildung mit polymerisierten siRNAs stabile Nanopartikel (siehe Schema). Die Poly‐siRNA/Glycolchitosan‐Nanopartikel (psi‐TGC) sind in vivo genügend stabil für den systemischen Transport von siRNAs. Das Abschalten von Tumorproteinen durch psi‐TGC resultierte in reduzierten Tumorgrößen und verminderter Tumorvaskularisation.</P>
TILT CORRECTION FOR A WIDE-FIELD ON-AXIS TELESCOPE USING THE SYMMETRICITY OF OPTICAL ABERRATIONS
Lee, Chung-Uk,Kim, Yunjong,Kim, Seung-Lee,Lee, Dong-Joo,Cha, Sang-Mok,Lee, Yongseok,Kim, Dong-Jin The Korean Astronomical Society 2021 Journal of The Korean Astronomical Society Vol.54 No.4
It is difficult for observers to conduct an optical alignment at an observatory without the assistance of an optical engineer if optomechanical parts are to be replaced at night. We present a practical tilt correction method to obtain the optimal optical alignment condition using the symmetricity of optical aberrations of a wide-field on-axis telescope at night. We conducted coarse tilt correction by visually examining the symmetry of two representative star shapes obtained at two guide chips facing each other, such as east-west or north-south pairs. After coarse correction, we observed four sets of small stamp images using four guide cameras located at each cardinal position by changing the focus positions in 10-㎛ increments and passing through the optimum focus position in the range of ±200 ㎛. The standard deviation of each image, as a function of the focus position, was fitted with a second-order polynomial function to derive the optimal focus position at each cardinal edge. We derived the tilt angles from the slopes converted by the distance and the focus position difference between two paired guide chip combinations such as east-west and north-south. We used this method to collimate the on-axis wide-field telescope KMTNet in Chile after replacing two old focus actuators. The total optical alignment time was less than 30 min. Our method is practical and straightforward for maintaining the optical performance of wide-field telescopes such as KMTNet.