http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Feng, Y.,Yang, X.J.,Wang, Y.B.,Li, W.L.,Liu, Y.,Yin, R.Q.,Yao, J.H. Asian Australasian Association of Animal Productio 2012 Animal Bioscience Vol.25 No.5
Immune stress is the loss of immune homeostasis caused by external forces. The purpose of this experiment was to investigate the effects of immune stress on the growth performance, small intestinal enzymes and peristalsis rate, and mRNA expression of nutrient transporters in broiler chickens. Four hundred and thirty-two 1-d-old broilers (Cobb500) were randomly assigned to four groups for treatment; each group included nine cages with 12 birds per cage. Group 1 = no vaccine (NV); Group 2 = conventional vaccine (CV); group 3 = lipopolysaccharide (LPS)+conventional vaccine (LPS); group 4 = cyclophosphamide (CYP)+conventional vaccine (CYP). The results demonstrated that immune stress by LPS and CYP reduced body weight gain (BWG), feed intake (FI), small intestine peristalsis rate and sIgA content in small intestinal digesta (p<0.05). However, the feed conversion ratio (FCR) remained unchanged during the feeding period. LPS and CYP increased intestinal enzyme activity, relative expression of SGLT-1, CaBP-D28k and L-FABP mRNAs (p<0.05). LPS and CYP injection had a negative effect on the growth performance of healthy broiler chickens. The present study demonstrated that NV and CV could improve growth performance while enzyme activity in small intestine and relative expression of nutrient transporter mRNA of NV and CV were decreased in the conditions of a controlled rational feeding environment. It is generally recommended that broilers only need to be vaccinated for the diseases to which they might be exposed.
Hardness Prediction and First Principle Study of Re-123(Re = Y, Eu, Pr, Gd) Superconductors
Weiwei Liu,Y. P. Zhou,X. L. Feng 대한화학회 2009 Bulletin of the Korean Chemical Society Vol.30 No.12
The chemical bond parameters of Y-123, Eu-123, Pr-123 and Gd-123 compounds have calculated using the chemical bond theory of complex crystals. Their hardness have been predicted by the chemical bond definition of hardness. The calculated results indicate that the Ba-O and RE-O types of bond have a lower covalent character and the Cu-O types of bond have greater covalency. The hardness values increase as the unit cell volume of the rare earth superconductor structures decrease.
Hardness Prediction and First Principle Study of Re-123(Re = Y, Eu, Pr, Gd) Superconductors
Liu, Weiwei,Zhou, Y.P.,Feng, X.L. Korean Chemical Society 2009 Bulletin of the Korean Chemical Society Vol.30 No.12
The chemical bond parameters of Y-123, Eu-123, Pr-123 and Gd-123 compounds have calculated using the chemical bond theory of complex crystals. Their hardness have been predicted by the chemical bond definition of hardness. The calculated results indicate that the Ba-O and RE-O types of bond have a lower covalent character and the Cu-O types of bond have greater covalency. The hardness values increase as the unit cell volume of the rare earth superconductor structures decrease.
Y.L.Feng,M.Ishitobi,A.Okuno,M.Nakaoka,H.W.Lee 전력전자학회 2001 ICPE(ISPE)논문집 Vol.2001 No.10
This paper presents a novel prototype of ZCS-PFM high frequency series resonant inverter using IGBT power module for electromagnetic induction eddy current-heated roller in copy and printing machines. The operating principle and unique features of this voltage source half bridge inverter with (wo additional soft commutation inductor snubber are presented including the transformer modeling of induction heated rolling drum. This soft switching inverter can achieve stable zero current soft commutation under a discontinuous and continuous resonant load current for a widely specified power regulation processing. The experimental results and computer-aided analysis of this inverter are discussed from a practical point of view.<br/>
Effects of Fabric Surface Energy on Human Thermophysiological Responses during Exercise and Recovery
Zhou, L.Y.,Li, Y.,Chung, J.,Tokura, H.,Gohel, M.D.I.,Kwok, Y.L.,Feng, X.W. The Korean Fiber Society 2007 Fibers and polymers Vol.8 No.3
The present paper reports a study on influences of fabric surface energy of cotton and polyester garments on clothing microclimates and human thermophysiological responses during intermittent exercise and recovery. Eight healthy males wearing the garments prepared performed exercises and rest according to the following protocol: rest for 30 min, run on treadmill for total 60 min of three sessions with different intensity and duration, and then sit quietly for 30 min for recovery, all at $30^{\circ}C$ and relative humidity of 30 %, while the microclimate humidity ($H_{mc}$) and temperature ($T_{mc}$), the clothing outside surface humidity ($H_{co}$) and temperature ($T_{co}$), the skin temperatures and ear canal temperature ($T_{ear_canal})$ were measured. The garments are made of: (a) hydrophilic and hydrophobic cotton knitted fabrics, and (b) hydrophilic and hydrophobic polyester knitted fabrics. During and after exercise, for cotton, hydrophilic garment resulted in significant lower ${\Delta}H_{mc}$, ${\Delta}H_{co}$, ${\Delta}T_{mc}$, during recovery, higher ${\Delta}{\bar{T}}_{sk}$, lower ${\Delta}T_{ear_canal}$ and ${\Delta}T_{forehead}$. For polyester, hydrophilic garment resulted in significantly lower ${\Delta}H_{co}$, ${\Delta}T_{co}$, higher ${\Delta}T_{forehead}$, during E1, E2 and recovery session but lower during E3. In summary, surface energy of cotton garments had significant influences on human thermophysiological responses during exercise and recovery, and hydrophilic cotton garment was better than hydrophobic one to reduce heat stress. Surface energy of polyester garments had influences of lower significance, and hydrophilic garment appeared better than hydrophobic garment.
Improvement of lower hybrid current drive systems for high-power and long-pulse operation on EAST
Wang M.,Liu L.,Zhao L.M.,Li M.H.,Ma W.D.,Hu H.C.,Wu Z.G.,Feng J.Q.,Yang Y.,Zhu L.,Chen M.,Zhou T.A.,Jia H.,Zhang J.,Cao L.,Zhang L.,Liang R.R.,Ding B.J.,Zhang X.J.,Shan J.F.,Liu F.K.,Ekedahl A.,Gonich 한국원자력학회 2022 Nuclear Engineering and Technology Vol.54 No.11
Aiming at high-power and long-pulse operation up to 1000 s, some improvements have been made for both 2.45 GHz and 4.6 GHz lower hybrid (LH) systems during the recent 5 years. At first, the guard limiters of the LH antennas with graphite tiles were upgraded to tungsten, the most promising material for plasma facing components in nuclear fusion devices. These new guard limiters can operate at a peak power density of 12.9 MW/m2 . Strong hot spots were usually observed on the old graphite limiters when 4.6 GHz system operated with power >2.0 MW [B. N. Wan et al., Nucl. Fusion 57 (2017) 102019], leading to a reduction of the maximum power capability. With the new limiters, 4.6 GHz LH system, the main current drive (CD) and electron heating tool for EAST, can be operated with power >2.5 MW routinely. Long-pulse operation up to 100 s with 4.6 GHz LH power of 2.4 MW was achieved in 2021 and the maximal temperature on the guard limiters measured by an infrared (IR) camera was about 540 C, much below the permissible value of tungsten material (~1200 C). A discharge with a duration of 1056 s was achieved and the 4.6 GHz LH energy injected into the plasma was up to 1.05 GJ. Secondly, the fully-activemultijunction (FAM) launcher of 2.45 GHz system was upgraded to a passive-active-multijunction (PAM), for which the density of optimum coupling was relatively low (below the cut-off value). Good coupling with reflection coefficient ~3% has been achieved with plasma-antenna distance up to 11 cm for the new PAM. Finally, in order to eliminate the effect of ion cyclotron range of frequencies (ICRF) wave on 4.6 GHz LH wave coupling, the location of the ICRF launcher was changed to a port that is located 157.5 toroidally from the 4.6 GHz LH system and is not magnetically connected
c-Cbl-Mediated Neddylation Antagonizes Ubiquitination and Degradation of the TGF-β Type II Receptor
Zuo, W.,Huang, F.,Chiang, Y.,Li, M.,Du, J.,Ding, Y.,Zhang, T.,Lee, H.,Jeong, L.,Chen, Y.,Deng, H.,Feng, X.H.,Luo, S.,Gao, C.,Chen, Y.G. Cell Press 2013 Molecular cell Vol.49 No.3
Transforming growth factor β (TGF-β) is a potent antiproliferative factor in multiple types of cells. Deregulation of TGF-β signaling is associated with the development of many cancers, including leukemia, though the molecular mechanisms are largely unclear. Here, we show that Casitas B-lineage lymphoma (c-Cbl), a known proto-oncogene encoding an ubiquitin E3 ligase, promotes TGF-β signaling by neddylating and stabilizing the type II receptor (TβRII). Knockout of c-Cbl decreases the TβRII protein level and desensitizes hematopoietic stem or progenitor cells to TGF-β stimulation, while c-Cbl overexpression stabilizes TβRII and sensitizes leukemia cells to TGF-β. c-Cbl conjugates neural precursor cell-expressed, developmentally downregulated 8 (NEDD8), a ubiquitin-like protein, to TβRII at Lys556 and Lys567. Neddylation of TβRII promotes its endocytosis to EEA1-positive early endosomes while preventing its endocytosis to caveolin-positive compartments, therefore inhibiting TβRII ubiquitination and degradation. We have also identified a neddylation-activity-defective c-Cbl mutation from leukemia patients, implying a link between aberrant TβRII neddylation and leukemia development.
Wang J.J.,Deng Q.J.,He Y.Y.,Feng Y.N.,Kang M.P.,Duan X.L.,Yang Y.L. 한국물리학회 2022 Current Applied Physics Vol.39 No.-
CCTO (Calcium copper titanate) powder as inorganic filler was synthesized by the Sol-gel method firstly. CCTO/ PVDF (Polyvinylidene fluoride) composite was fabricated by solution mixing based on high temperature resistance of PVDF and insulated property of CCTO. The composite of CCTO/PVDF were characterized by X-ray diffraction, Fourier Transform infrared spectroscopy, Scanning Electron Microscope and impedance analysis. The results showed that the addition of CCTO and increasing in its content did not affect the phase- and microstructure of the composites,but the increase of CCTO content can induce the generation of C–F new bonds. PVDF/CCTO composites were enhanced in performance of thermal and frequency-depended stability with increasing in the fraction of CCTO. The dielectric constant of CCTO/PVDF composite materials with 50% CCTO achieved to a maximum value of 50 almost, which is 5 times higher the pure PVDF. The conductivity felled into 10-8 to 10-1 S m-1 during the frequency of 102–108 Hz. The composite material would be expected to be applied in the field of integrated circuit.