        Experimental Investigation of the Effect of Generator Temperature on the Performance of Solution Transportation Absorption Chiller

        Koji Enoki,Fumi Watanabe,Atsushi Akisawa,Toshitaka Takei 대한설비공학회 2017 International Journal Of Air-Conditioning and Refr Vol.25 No.3

        It is effective to recover waste heat to reduce primary energy consumption. From this point of view, we proposed and examined a new idea of heat transportation using ammonia–water as the working fluid in the system named the Solution Transportation Absorption chiller (STA). As waste heat sources are not necessarily located close to areas of heat demand, conventionally, absorption chillers are located on heat source side and produce chilled water that is transported to heat demand side through pipelines with an insulation. In contrast, the proposed system STA divides an absorption chiller into two parts. The generator and the condenser are located on heat source side while the evaporator and the absorber are on heat demand side. Both the conventional system and STA system satisfy the same boundary condition of heat recovery and heat supply to the demand side, STA can work for transferring thermal energy as the conventional system does even though the temperature of the media is ambient without an insulation. Our previous studies of the STA were based on the experimental investigation with the STA facility where the cooling power was 90kW (25.6 refrigeration ton) at the generator temperature 120 ∘C from 0 m (normal absorption chiller) to 1000 m. Thus, the Coefficient of Performance (COP) of STA was found to have almost the same value of 0.65 with conventional absorption chillers without depending on the transportation distances. The objective of this study is to examine the effect of generator temperature from 100 ∘C to 120 ∘C on the performance of solution transportation of ammonia–water solution, because the generator temperature is directly linked to the waste heat temperature, so its effect needs to be investigated. The experimental facility tested the performance with 0 m (normal absorption chiller), 200 m and 500 m distance. The results indicate that the effect of the generator temperature and solution transportation distances showed no significant on the COP.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼