http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Assessment of stability of early loaded nano-coated hydroxyapatite implants in posterior maxilla
Ola Abdelsamad Amin,Ingy Mohamed Shehata,Heba Mohamed Kamel,Nader Nabil Elbokle 대한치과이식임플란트학회 2024 Journal of Dental Implant Research Vol.43 No.1
Purpose: This study assessed the stability of nano-coated hydroxyapatite implants in the posterior maxilla after early loading. Materials and Methods: This study was conducted on nine patients missing at least one maxillary posterior tooth. Ten nano-coated hydroxyapatite implants were inserted in nine patients and subjected to early loading according to the secondary stability readings taken by Osstell®. The implant stability was measured at the time of implant insertion (T0), 4 (T1), 6 (T1 modified), weeks, and four months (T2) after surgery. Cone-beam computed tomography (CBCT) was performed in all patients before treatment started. Nine implants healed well, but one implant failed due to infection. Results: The secondary stability results six weeks after implant insertion were sufficient for implant loading. Significant differences were observed between T0, T1, T1 modified, and T2. Conclusions: Nano-coated hydroxyapatite implants are a good choice in the posterior maxilla because they allow early loading.