http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
중복요관을 가진 소아환자의 <sup>99m</sup>Tc-DMSA 검사에서 부분적 관심영역 설정에 따른 신기능 평가에 관한 연구
남궁혁,오신현,김정열,최윤정,김재삼,이창호,Nam-Koong, Hyuk,Oh, Shin Hyun,Kim, Jung Yul,Choi, Yoon Jung,Kim, Jae Sam,Lee, Chang Ho 대한핵의학기술학회 2013 핵의학 기술 Vol.17 No.1
Purpose: A duplicated ureter is congenital renal malformations with ureter in two. Patients with duplicated ureter are in force to $^{99m}Tc-DMSA$ scan at surgery before and after. In existing examination, at produce result after $^{99m}Tc-DMSA$ scan, didn't compare to upper pole and lower pole with malformed kidney and compared to only relative uptake ratio. Therefore, this study will examine about utility of set a partial region of interest and to functional recovery of renal cell through change of upper pole uptake ratio of malformed kidney by setting each partial region of interest in upper pole and lower pole of malformed kidney in $^{99m}Tc-DMSA$ examination in surgery before and after. Materials and Methods: Pediatric patients with malformed kidney of incomplete duplicated ureter, 15 patients were enrolled in this study. Scanning were scan 3 to 4 hours after injection of $^{99m}Tc-DMSA$ 1.5 ~ 1.9 MBq/kg. Region of interest were each set in normal kidney, upper pole and lower pole with malformed kidney. Region of interest were set with same condition and method to images of surgery before and after that radio technologist 1 person, resident of nuclear medicine 1 person and doctor of urology together. Therefore, this study were compared to uptake ratio (A: B: C) that normal kidney (A), lower pole of malformed kidney (B) and upper pole of malformed kidney (C) about uptake ratio changes of malformed kidney in follow-up examination of surgery before and after. Results: When compared to 15 patients, uptake ratios were increased 7 persons and decreased 8 persons. Among increased 7 persons, it were periods of follow-up examination that 2 persons were 14 months, 4 persons were 12 months and 1 person was 8 months after surgery. Among decreased 8 persons, it were periods of follow-up examination that 4 persons were 12 months 3 persons were 6 months and 1 persons were 4 months after surgery. Conclusion: Existing study could not see the exact uptake ratio changes of malformed kidney because using only the overall Left-Right kidney uptake ratios. But a setting partial region of interest was able to see exactly what changes in the uptake of each upper pole and lower pole of malformed kidney. Because recovery of renal parenchymal cells is difficult in an evaluation of short period of time, follow-up examination should be made in long period of time. How to set up partial region of interest be thought that it would be useful.
비뇨기암 환자에서 <sup>11</sup>C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용
남궁혁,함준철,김상규,최용훈,임한상,김재삼,Nam-Koong, Hyuk,Ham, Joon chul,Kim, Sang kyoo,Choi, Yong hoon,Lim, Han sang,Kim, Jae sam 대한핵의학기술학회 2016 핵의학 기술 Vol.20 No.2
Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.
I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가
김정열,김주연,남궁혁,강천구,김재삼,Kim, Jung Yul,Kim, Joo Yeon,Nam-Koong, Hyuk,Kang, Chun Goo,Kim, Jae Sam 대한핵의학기술학회 2014 핵의학 기술 Vol.18 No.1
Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy ${\gamma}$-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.
유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화
이다영,남궁혁,조석원,오신현,임한상,김재삼,이창호,박훈희,Lee, Da-Young,Nam-Koong, Hyuk,Cho, Seok-Won,Oh, Shin-Hyun,Im, Han-Sang,Kim, Jae-Sam,Lee, Chang-Ho,Park, Hoon-Hee 대한핵의학기술학회 2012 핵의학 기술 Vol.16 No.2
Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.
PET/CT 검사에서 추가 검사 시 수분섭취에 따른 <sup>18</sup>F-FDG의 신장 섭취 감소에 대한 고찰
이이랑,김상규,함준철,남궁혁,임한상,김재삼,Lee, Yi Lang,Kim, Sang Gyu,Ham, Jun Chul,Nam-Koong, Hyuk,Lim, Han Sang,Kim, Jae Sam 대한핵의학기술학회 2016 핵의학 기술 Vol.20 No.1
Purpose By ingestion of 18F-FDG of kidney of PET/CT during the inspection, if additional examination is required, depending on whether you want to water intake, we want to confirm a change in the rate of decrease of F-18 FDG of the kidney. Materials and Methods The 80 patients without kidney disease were performed PET/CT examination. Device was analyzed after setting the kidney to a three-dimensional region of interest. In patients require additional examination, and inspection after 30 minutes, a PET/CT torso examination after the water of the 500 cc ingested at a time. After the addition of both water intake group and no hydration group of kidney of SUV, it was compared with PET/CT torso scan. Results High and low of the kidney SUV did not show a significant difference in the rate of decrease. Reduction rates of background (BKG) of additional examination was 2.8% and reduction rates of SUV was 49.7% (Hydration) : -6.8% (No hydration), so did show a significant difference. In the image blind test, the average point score of hydration and no hydration was 34.25 : 17.25. Conclusion An undercurrent of 18F-FDG in the kidney at the time of torso examination, it was confirmed that the reduction rate after the addition of water intake is high. It is considered that can be expected to improve the quality of an image due to a decrease in elongation through the kidneys examination with additional fluid intake as needed intake.
뇌병변 환자에서 흡인성 폐렴 진단을 위한 Salivagram의 유용성
오신현,최영숙,노동욱,남궁혁,김재삼,이창호,Oh, Shin Hyun,Choi, Yung Sook,Ro, Dong Wook,Nam-Koong, Hyuk,Kim, Jae Sam,Leee, Chang Ho 대한핵의학기술학회 2013 핵의학 기술 Vol.17 No.1
Purpose: Bed, living a long time is required in adult patients with brain lesions such as stroke, traumatic brain injury, and Parkinson's disease, causing pneumonia and respiratory diseases may be due to aspiration of food or saliva. In patients with recurrent pneumonia or pulmonary symptoms, there is a need to determine the possibility of pulmonary aspiration due to aspiration of saliva. Materials and Methods: Saliva due to aspiration pneumonia diagnosis in patients with brain lesions request for inspection to the Department of Nuclear Medicine, 10 patients (male 6, female 4) were included in this study. Patients were fasted before the test, $^{99m}Tc_{O4}$ 185 MBq (5 mCi) of less than 1 mL of solution was administered in the oral cavity. Administration and 20 minutes of dynamic imaging acquisition, and immediately after that the static images were acquired. Delayed scan after 2-4 hours if necessary. Results: Positivity rate of all 10 patients was 60%. In 4 patients showed positive reactions after the administration of oral cavity in a 20-minute dynamic imaging were able to confirm whether the aspiration. In the remaining 2 patients, four hours of additional delay tests were able to confirm whether the aspiration. Conclusion: Does not require changes in patient posture compared to the other checks that can be diagnosed with aspiration pneumonia. A simple test and takes less time. Therefore be useful in providing information for the diagnosis and treatment modality.