http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Glutaraldehyde 와 자동 세척기를 이용한 내시경 소독방법의 임상에서의 유용성
김영호,손희정,윤성원,최규완,이남용,백승운,이준행,고광철,이풍렬,이종철,송재훈,안병훈,김재준,최원혁,홍일철 대한소화기내시경학회 2001 Clinical Endoscopy Vol.22 No.6
Background/Aims: Safety of endoscopic procedures has been a major issue over the last 10 years. Most endoscopy units use 2% glutaraldehyde and automated endoscope reprocessors (AERs) for disinfecting gastrointestinal endoscopes. We attempted an in-use evaluation of the current reprocessing procedures. Methods: Thirty flexible endoscopes were randomly collected just after upper endoscopic examinations and were disinfected using 2% glutaraldehyde in an AER. Cultures were taken from biopsy channels (S-l), tip of the insertion tubes (S-2), umbilical cords (S-3), and angulation knobs (S-4). Results: In 63,3% (19/30) of endoscopes, there was no microbial contamination after disinfection procedures. The culture positive rates of S-l, S-2, S-3, and S-4 samples were 20,0%, 0.0%, 3.3%, and 20.0%, respectively. Microorganisms of 13 species were identified, but there was no pathogen related with reported infectious complications after endoscopic procedures. Conclusions: Current disinfection procedure using 2% glutaraldehyde and an AER appears to be very effective in decontaminating patient-used endoscopes. Low level microbial contamination of endoscopes after conventional reprocessing methods may not impose great risk on patients.
Ji Chang Woo,Kim Nam-Jung,Lee Sang-Guei,Hwang-Yong Kim,Choi Hoon-Sik,Song In-Sun,Ko Jee Sun 한국응용곤충학회 2010 한국응용곤충학회 학술대회논문집 Vol.2010 No.05
We analyzed the chirp sound and behavior of Teleogryllus emma with observation system, which was consisted of computer, ccd-camera and microphone. Computational methods of wavelet transformation and Self-Organizing Maps (SOM) were utilized to characterized the chirp sound of insect species for automatic counting in this study. Wavelets were initially applied to feature extraction of the chirp sound. Wavelet coefficients were accordingly calculated based on the basis function (e.g., Morlet). The obtained coefficients were subsequently provided to count number of chirps in each song. Sound structure of insect specimens consisted with long chirp and short chirp and the patterns of song were grouped by frequency of long chirp and short chirp. The song patterns of insect specimens were divided by Self-Organizing Map (SOM) that was used number of chirp as input data. Application of computational methods to automatic detection of chirp sound was further discussed for obtaining objective assessment in behavior science.
Yu Jin Cho,Jae Chul Lee,Bong Gu Kang1,2,Jaeyeol An,Hyeon Suk Song1,2,Onju Son,Do-Hyun Nam,Choong Ik Cha,Kyeung Min Joo 대한해부학회 2011 Anatomy & Cell Biology Vol.44 No.2
Nitric oxide (NO) modulates the activities of various channels and receptors to participate in the regulation of neuronal intracellular Ca2+ levels. Ca2+ binding protein (CaBP) expression may also be altered by NO. Accordingly, we examined expression changes in calbindin-D28k, calretinin, and parvalbumin in the cerebral cortex and hippocampal region of neuronal NO synthase knockout(−/−) (nNOS−/−) mice using immunohistochemistry. For the first time, we demonstrate that the expression of CaBPs is specifically altered in the cerebral cortex and hippocampal region of nNOS−/− mice and that their expression changed according to neuronal type. As changes in CaBP expression can influence temporal and spatial intracellular Ca2+ levels, it appears that NO may be involved in various functions, such as modulating neuronal Ca2+ homeostasis, regulating synaptic transmission, and neuroprotection, by influencing the expression of CaBPs. Therefore, these results suggest another mechanism by which NO participates in the regulation of neuronal Ca2+ homeostasis. However, the exact mechanisms of this regulation and its functional significance require further investigation.
Development of Cost-Effective and High-Property Mask in Flatron
Song, Jong-Mok,Kim, Byoung-Nam,Koh, Nam-Je,Chun, Hyun-Tae,Park, Ki-Bum The Korean Infomation Display Society 2001 Journal of information display Vol.2 No.1
We developed the tension mask of which thickness increased from 25 urn to 50 urn to reduce the mask cost and improve the vibration property. First of all, the limitation by which rail structure can support is calculated and the optimal thickness of mask is determined. To prevent the reduction of brightness and brightness uniformity, the dimensions of mask was reassigned. As a result, the increase of mask thickness brought about a reduction in cost and improvement of howling property which had been a weak point of flat CRTs.
A Study of FIV Characteristics of a Coaxial Double-Tube-Type Cross Vessel for a VHTR
SONG, Kee Nam,KIM, Yong Wan,PARK, Sang Chul Atomic Energy Society of Japan 2010 Journal of nuclear science and technology Vol.47 No.6
<P>A Very High Temperature Gas-Cooled Reactor (VHTR) has been selected as a high-energy heat source of the order of 950°C for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube-type cross vessel is a key component connecting a reactor pressure vessel and an intermediate heat exchanger in the VHTR. In this study, a structural sizing methodology for the primary HGD of a VHTR is proposed in order to modulate a flow-induced vibration (FIV). As an example, a structural sizing of a horizontal HGD with a coaxial double-tube structure was carried out using the proposed method. These activities include deciding the geometric dimensions, selecting the material, and evaluating the strength of the coaxial double-tube-type cross vessel components. Also, in order to compare the FIV characteristics of the proposed design cases, a fluid-structure interaction (FSI) analysis of the HGD was carried out using the ADINA code.</P>
Song, Sang-Wook,Kang, Sung-Goo,Kim, Kyung-Soo,Kim, Moon-Jong,Kim, Kwang-Min,Cho, Doo-Yeoun,Kim, Young-Sang,Joo, Nam-Seok,Kim, Kyu-Nam Hindawi 2018 Pain research & management : the journal of the Ca Vol.2018 No.-
<P><B>Introduction</B></P><P> A nonspecific symptom, fatigue accompanies a variety of diseases, including cancer, and can have a grave impact on patients' quality of life. As for multidimensional instruments, one of the most widely used is the Multidimensional Fatigue Inventory (MFI). This study aims to verify the reliability and validity of the MFI Korean (MFI-K) version. </P><P><B>Materials and Method</B></P><P> This study was performed at four university hospitals in the Republic of Korea. Among outpatients visiting the Department of Family Medicine, those complaining of fatigue or visiting a chronic care clinic were enrolled in this study. A total of 595 participants were included, and the mean age was 42.2 years. </P><P><B>Results</B></P><P> The Cronbach's alpha coefficient of the MFI-K was 0.88. The MFI-K had good convergent validity. Most subscales of the MFI-K were significantly correlated with the Visual Analogue Scale (VAS) and Fatigue Severity Scale (FSS). In particular, general and physical fatigue had the greatest correlation with the VAS and FSS. Although the English version of MFI had five subscales, the factor analysis led to four subscales in the Korean version. </P><P><B>Conclusion</B></P><P> This study demonstrated the clinical usefulness of MFI-K instrument, particularly in assessing the degree of fatigue and performing a multidimensional assessment of fatigue.</P>
Song, Nam-Yoong,Kim, Hyong-Ha,Park, Tae-Sook,Yoon, Min-Joong Korean Society of Photoscience 2005 Journal of Photosciences Vol.12 No.2
A new assay technique to distinguish between pure compounds and the isomeric mixtures has been suggested using single molecule (SM) fluorescence detection technique. Since the number of emission spots in a fluorophorespread film prepared from a genuine dye solution was determined by experimental condition, the deviation of spot numbers from the expected values could be considered to be an indication of lower purity of the sample solution. The lower limit of sample concentration for this assay was determined to be $5{\times}10^{-10}$ M to show uniform number of expected spots within 10% uncertainties in our experimental condition. An individual fluorescence intensity distribution for a mixture of isomers having doubly different emissivities was simulated by adding distributions obtained from Cy3 and nile red (NR) independently. The result indicated that the mixture could be identified from the pure compounds through the difference in the number of Gaussian functions to fit the distribution. This new assay technique can be applied to the purity test for synthetic biofluorophores which are usually prepared in small quantities not enough for classical ensemble assays.