http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Ramyadharshini, Tamilkumaran,Sherwood, Inbaraj Anand,Vigneshwar, V Shanmugham,Prince, Prakasam Ernest,Vaanjay, Murugadoss The Korean Academy of Conservative Dentistry 2020 Restorative Dentistry & Endodontics Vol.45 No.1
Objectives: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. Materials and Methods: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. Results: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. Conclusions: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15.
Jarvin Mariadhas,Sarojini Jeeva Panchu,Hendrik C. Swart,Daniel Rani Rosaline,Govindasamy Murugadoss,Durai Govindarajan,Soorathep Kheawhom,Savairoyan Stephen Rajkumar Inbanathan,Awais Bokhari,Lai Fatt 한국공업화학회 2023 Journal of Industrial and Engineering Chemistry Vol.128 No.-
Dangerous non-biodegradable compounds are released into the environment due to the increased humanpopulation and industrialization. A simple green synthesis approach of novel silver (Ag)-doped copperoxide (CuO) anchored graphene oxide (GO) nanosheets (Ag-CuO@GO) via energy-efficient microwaveheating method has been developed for photocatalytic and antimicrobial applications. Tea extract is usedas a capping and reducing agent. The prepared Ag-CuO@GO nanocomposites (NCs) used for photocatalyticand antimicrobial activities are investigated systematically. The highly crystalline, wellinterconnectedAg-CuO nanoparticles (NPs) over GO provide an enhanced surface area of 24.1 m2/gand an efficient pore diameter of 15.1 nm with more active sites. A reduced optical bandgap (Eg) of1.48 eV obtained for the Ag-CuO@GO NCs, less than that of the bare and Ag-CuO, indicates that it canfunction as an efficient photocatalyst by harvesting solar energy. As demonstrated by the suppressedPL of the ternary Ag-CuO@GO nanocatalysts, additional of Ag and GO can efficiently separate the chargecarriers. Ag-CuO@GO exhibited an 89% increase in the dye removal rate of MB dye and high antimicrobialactivity against S.aureus, E.coli and Candida albicans that that of bare CuO and binary NCs. The synthesizednovel Ag-CuO@GO NCs show promise as potential photocatalysts for the pollutant degradation andantimicrobial activity.
Ramyadharshini Tamilkumaran,Anand Sherwood Inbaraj,Vigneshwar V Shanmugham,Ernest Prince Prakasam,Vaanjay Murugadoss 대한치과보존학회 2020 Restorative Dentistry & Endodontics Vol.45 No.2
Objectives: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. Materials and Methods: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. Results: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. Conclusions: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15.