RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Mitigating Disturbance in Harmonic Voltage Using Grid‑side Current Feedback for Grid‑connected LCL‑fltered Inverter

        Ye Zhang,Muqin Tian,Jiancheng Song,XiaoYu Zhang 대한전기학회 2020 Journal of Electrical Engineering & Technology Vol.15 No.3

        As the interface between new energy and power grid, the grid-connected LCL-fltered inverter plays a key role in energy conversion. However, it performs poor at rejecting grid background harmonics that distort the grid-side current and afect the quality of the output power of the inverter. Thus, a feedback strategy for the grid-side current employing the proportional integral and resonant controller (PI+HC) is used to mitigate the harmonics of the grid-side current and improves the quality of the output power of the grid-connected LCL-fltered inverter. Owing to the grid-side current feedback control system is unstable, improved High Pass Filter (HPF) active damping based on unit delay feedback is used to guarantee stability and efectiveness of PI+HC. The proposed method for mitigating grid-side current harmonics is validated by a detailed simulation and the results of experiments.

      • KCI등재

        Contribution of Electrical–Thermal Aging to Slot Partial Discharge Properties of HV Motor Windings

        Ailiang Kang,Muqin Tian,Jiancheng Song,Lingyan Lin,Wei Li,Zhipeng Lei 대한전기학회 2019 Journal of Electrical Engineering & Technology Vol.14 No.3

        During the operation of HV motor, the abrasion of stator windings because of vibration caused by electromagnetic force will lead to slot partial discharge (PD). Furthermore, the superheat induced by overcurrent or poor heat dissipation will aggravate the slot PD. To understand the developing process of slot PD and comprehend the infl uences of aging factors on slot PD properties, two discharge bar models were made under electrical–thermal aging. At triple the rated line-to-earth voltage of 6 kV, two stator bars were aged for 37 days under diff erent temperatures. The slot PD was measured during diff erent aging stages, and visual observations of the insulation and stator core surface were made at the beginning and the end of aging. The experiment results indicate that electrical–thermal aging has a signifi cant impact on the slot PD activities. The slot PD was intense under higher thermal stress, and the surfaces of insulation and stator core were oxidized after the long-time aging. This study can provide a judging basis for fault diagnosis of HV motors.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼