http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
A real-time sorting algorithm for in-beam PET of heavy-ion cancer therapy device
Ke, Lingyun,Yan, Junwei,Chen, Jinda,Wang, Changxin,Zhang, Xiuling,Du, Chengming,Hu, Minchi,Yang, Zuoqiao,Xu, Jiapeng,Qian, Yi,She, Qianshun,Yang, Haibo,Zhao, Hongyun,Pu, Tianlei,Pei, Changxu,Su, Hong Korean Nuclear Society 2021 Nuclear Engineering and Technology Vol.53 No.10
A real-time digital time-stamp sorting algorithm used in the In-Beam positron emission tomography (In-Beam PET) is presented. The algorithm is operated in the field programmable gate array (FPGA) and a small amount of registers, MUX and memory cells are used. It is developed for sorting the data of annihilation event from front-end circuits, so as to identify the coincidence events efficiently in a large amount of data. In the In-Beam PET, each annihilation event is detected by the detector array and digitized by the analog to digital converter (ADC) in Data Acquisition Unit (DAQU), with a resolution of 14 bits and sampling rate of 50 MS/s. Test and preliminary operation have been implemented, it can perform a sorting operation under the event count rate up to 1 MHz per channel, and support four channels in total, count rate up to 4 MHz. The performance of this algorithm has been verified by pulse generator and <sup>22</sup>Na radiation source, which can sort the events with chaotic order into chronological order completely. The application of this algorithm provides not only an efficient solution for selection of coincidence events, but also a design of electronic circuit with a small-scale structure.
Efficient continuous epoxidation of biodiesel in a microstructured reactor
Xingjun Yao,Yan Zhang,Lingyun Du,Huiqiang Liu,Song Jiang 한국화학공학회 2016 Korean Journal of Chemical Engineering Vol.33 No.9
Efficient continuous epoxidation of biodiesel with peracetic acid generated in situ from hydrogen peroxide and acetic acid was studied in detail in a microstructured reactor. The effects of micromixer type, reaction temperature, catalyst usage, flow rate and residence time were considered. Results show the T-type glass micro-structured reactor (TTGMR) outperforms the interdigital multilamination micromixer. Under the optimized conditions, the final product from TTGMR has an epoxy value of 6.5 and an iodine value of 2.2.
Evaluation of energy correction algorithm for signals of PET in heavy-ion cancer therapy device
Niu, Xiaoyang,Yan, Junwei,Wang, Xiaohui,Yang, Haibo,Ke, Lingyun,Chen, Jinda,Du, Chengming,Zhang, Xiuling,Zhao, Chengxin,Kong, Jie,Su, Hong Korean Nuclear Society 2020 Nuclear Engineering and Technology Vol.52 No.1
In order to solve the contradiction between requirements of high sampling rate for acquiring accurate energy information of pulses and large amount of data to be processed timely, the method with an algorithm to correct errors caused by reducing the sampling rate is normally used in front-end read-out system, which is conductive to extract accurate energy information from digitized waveform of pulse. The functions and effects of algorithms, which mainly include polynomial fitting with different fitting times, double exponential function fitting under different sampling modes, and integral area algorithm, are analyzed and evaluated, and some meaningful results is presented in this paper. The algorithm described in the paper has been used preliminarily in a prototype system of Positron Emission Tomography (PET) for heavy-ion cancer therapy facility.